K971043 · Golden Technologies, Inc. · INI · Aug 1, 1997 · Physical Medicine
Device Facts
Record ID
K971043
Device Name
GOLDEN EAGLE
Applicant
Golden Technologies, Inc.
Product Code
INI · Physical Medicine
Decision Date
Aug 1, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3800
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The scooter is designed to enhance user mobility. This device is ideal for users that are unable to walk yet able to transfer from one platform to another, users that have some difficulty walking, and users who simply prefer to ride but can, if need be, walk.
Device Story
Golden Eagle GT2000 is a modular, electrically-powered 3-wheeled scooter; intended to enhance user mobility. Input: user operation via control panel (direction/speed control, wig-wag potentiometer). Transformation: 24VDC power from 2-12VDC batteries drives permanent magnet motor coupled to transaxle; disc-type coil-activated electric brake provides stopping. Output: motorized transport. Used in various environments by patients with mobility limitations. Features include swivel seat, headlight, and suspension system (leaf/coil springs). Healthcare provider/user interaction: user operates controls to navigate; device facilitates independent mobility for those with walking difficulties. Benefits: improved mobility and independence for users capable of transferring between platforms.
Clinical Evidence
Bench testing only. No clinical data provided. Safety and effectiveness supported by testing to UL 9F15 (battery charger), ISO 7176-1 (static stability), ISO 7176-2 (dynamic stability), and EMC standards including EN55011 (radiated/conducted emissions) and IEC 801-2/1000-4-3 (electrostatic discharge and radiated electric field immunity).
Technological Characteristics
Modular 3-wheeled electric scooter. 24VDC power source (2-12VDC batteries). Permanent magnet motor with transaxle drive. Disc-type coil-activated electric brake. Features leaf spring rear and coil spring front suspension. Solid tires. Gas-filled seat post. Includes front safety light. Control panel with voltage meter, horn, and speed limit potentiometer. Complies with ISO 7176 series and IEC/EN EMC standards.
Indications for Use
Indicated for individuals with mobility impairments, including those unable to walk but capable of transferring between platforms, those with difficulty walking, and those who prefer assisted mobility.
Regulatory Classification
Identification
A motorized three-wheeled vehicle is a gasoline-fueled or battery-powered device intended for medical purposes that is used for outside transportation by disabled persons.
{1}
FROM : GOLDEN TECHNOLOGIES 717 883 0502 1997.03-19 11:41 #519 P.03/04
GOLDEN K971043
TECHNOLOGIES, inc. aus. 1, 1997
401 Bridge Street
Old Forge, PA 18518
(717) 451-7477 • Fax (717) 451-7494
HTTP://www.GoldTech.com
# 510(k) SUMMARY
1. This 510(k) Summary is submitted, in conjunction with a full submission, this 19th day of March, 1997, by:
Chris McConnell
Director of Operations/Engineering
Scooter Division
Golden Technologies
401 Bridge Street
Old Forge, PA 18518
Telephone: 717-498-6962
717-451-7477 x 241 (Chris McConnell)
717-451-7477 x 232 (Fred Kiwak)
Fax: 717-451-7494
2. The device is as follows:
Trade name: Golden Eagle GT2000
Common Name: Motorized 3-wheeled vehicle
Classification Name: Motorized electric 3-wheeled vehicle
(per 21 CFR 890.3800)
Class II 89INI
3. Predicate device on which we base equivalence:
Pride Health Care Legend Scooter
(K926295) Product Code 89INI
4. Description of Device:
This is a modular electrically-powered scooter including as modular components a seat, seat post, main front frame and, motor assembly, removable rear plastic body and 2-12VDC batteries connected in series to provide a 24VDC power source. The scooter is built in a manner allowing quick and easy assembly/disassembly.
162
03/19/97 WED 11:07 [TX/RX NO 5905]
{2}
The mainframe includes a rotably-affixed front wheel and tiller for steering, a seat post pedestal (receiver), a user control panel with direction/speed control, a headlight, a rear half weldment (anti-tip wheelie bars and leaf springs) hinged to main floor pan and a latch/receiver mechanism to capture motor assembly locking bar.
The motor assembly includes a pair of rear wheels coupled to a transaxle which is driven by an electric motor. The motor assembly also includes an electric brake, motor control board, battery charger, 2-12VDC batteries, a battery tray and a connector panel for battery and control signal cable hook-ups.
The motor assembly is secured to main front frame by threading motor carriage pins just under rear weldment leaf springs, rotating motor assembly to a vertical (upright) position, placing motor assembly locking bar into main frame latch receiver and moving latch to a vertical (upright) position, placing motor assembly locking bar into main frame latch receiver and moving latch to a vertical (upright) position, insert seat post into seat pedestal (receiver), hold latch in a "locked" upright position.
## 4. Intended use of the device
The scooter is designed to enhance user mobility. This device is ideal for users that are unable to walk yet able to transfer from one platform to another, users that have some difficulty walking, and users who simply prefer to ride but can, if need be, walk.
## 5. Similarities and Differences to predicate device
### Similarities
1. The "Golden Eagle" and "Legend" scooters both use a 24VDC permanent magnet motor attached to a transaxle drive unit.
2. Both use a disc-type coil-activated electric brake.
3. The motor control boards are of the same basic design and concept.
4. Each has an industry-typical wig-wag potentiometer, forward/reverse speed control, along with a speed limit potentiometer.
5. Both scooters feature upholstered seats with removable arms and height adjustment capability. Seats on each swivel 360°.
6. Each uses 2 12VDC U-1 type batteries as their power source, and each uses a commercially available built-in charger to replenish depleted batteries.
7. All major dimensions are similar.
8. The "control panel" on each has a voltage meter, horn switch and speed limit potentiometer.
163
359
{3}
38
# Differences
| Suspension | Legend | Golden Eagle |
| --- | --- | --- |
| | No suspension system | Leaf springs near rear of scooter and coil springs on the front fork |
| Tires | Pneumatic tires | Solid tires (no flats) |
| Wig-wag paddle controls | Lower thumb type only | Upper and lower wig-wag paddle controls |
| Seat post | Tube with cervice pin height adjustment | Gas-filled for auto height adjustment and cushioned ride. |
| Lights | None | Standard front safety light |
| Seat pedestal | Mounts on back of scooter
Batteries on front half | Mounts on front of scooter
Batteries on rear motor assbly |
# 6. Safety and Effectiveness Information
The scooter has been tested to the following standards:
UL Listed 9F15 Battery charger
ISO 01 (Static Stability) - ISO/CD 7176-1:1995-05-03 (E) (See Section 6A for results)
ISO 02 (Dynamic Stability) ISO 7176-2:Draft 1996-02-09 (See Section 6A for results)
EMC Evaluation in accordance with the Draft ISO EMC Addition to IS 7176-14:
EN55011 Radiated emissions PASS
EN55011 Conducted emissions PASS WITH FIX
IEC 801-2 Electrostatic Discharge Immunity PASS
IEC 1000-4-3 Radiated Electric Field Immunity (Draft) PASS
{4}
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration
9200 Corporate Boulevard
Rockville MD 20850
Mr. Chris McConnell
Golden Technologies, Inc.
401 Bridge Street
Old Forge, Pennsylvania 18518
Re: K971043
Golden Eagle GT2000
K971050
Golden Hawk
Regulatory Class: II
Product Code: INI
Dated: May 28, 1997
Received: May 30, 1997
AUG - 1 1997
Dear Mr. McConnell:
We have reviewed your Section 510(k) notification of intent to market the devices referenced above and we have determined these devices are substantially equivalent (for the indications for use stated in the enclosures) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the devices, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your devices are classified (see above) into either class II (Special Controls) or class III (Premarket Approval), they may be subject to such additional controls. Existing major regulations affecting your devices can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your devices in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{5}
Page 2 - Mr. Chris McConnell
This letter will allow you to begin marketing your devices as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your devices to legally marketed predicate devices results in a classification for your devices and thus, permits your devices to proceed to the market.
If you desire specific advice for your devices on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your devices, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,

Celia M. Witten, Ph.D., M.D.
Director
Division of General and Restorative Devices
Office of Device Evaluation
Center for Devices and Radiological Health
Enclosures
{6}
# SECTION 3
## DEVICE DESCRIPTIVE INFORMATION
### SECTION 3A Intended Use
The Golden Technologies, Inc. Golden Hawk is designed to enhance user mobility. This device is ideal for users that are unable to walk yet able to transfer from one platform to another; users that have some difficulty walking, and users who simply prefer to ride but can, if need be, walk.

Over-the-Counter Use
3
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.