ELECTROSURGICAL ELECTRODE

K970987 · Fusion Medical Technologies, Inc. · GEI · May 5, 1997 · General, Plastic Surgery

Device Facts

Record IDK970987
Device NameELECTROSURGICAL ELECTRODE
ApplicantFusion Medical Technologies, Inc.
Product CodeGEI · General, Plastic Surgery
Decision DateMay 5, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4400
Device ClassClass 2
AttributesTherapeutic

Indications for Use

Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended to provide electrocautery over a large surface.

Device Story

Fusion Ball Tip Electrode; reusable monopolar electrosurgical accessory. Input: electrical energy from standard electrosurgical generator via electrosurgical pencil/chuck. Operation: delivers high-frequency current to tissue via 99% pure silver ball tip for electrocautery. Used by clinicians in surgical/clinical settings. Output: thermal tissue effect (coagulation/cautery). Benefits: provides large surface area electrocautery; reusable design via autoclave sterilization.

Clinical Evidence

Bench testing only; no clinical data provided. Equivalence based on design, material biocompatibility, and intended use similarity to predicate.

Technological Characteristics

Monopolar electrosurgical electrode. Materials: Stainless steel shank, Polyphenylsulfone insulation, 99% pure silver tip. Dimensions: 3/32 inch (2.4 mm) shaft. Energy: Electrosurgical (RF). Sterilization: Gamma irradiation (initial), autoclave (reusable). Biocompatibility: ISO 10993-1 compliant.

Indications for Use

Indicated for use by practitioners for electrocautery over a large surface area in patients requiring electrosurgical procedures.

Regulatory Classification

Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

Predicate Devices

Submission Summary (Full Text)

{0} 046 K970987 510(k) Summary Fusion Medical Technologies, Inc. Ball Tip Electrode MAY - 5 1997 1. Sponsor: Fusion Medical Technologies, Inc. 1615 Plymouth Street Mountain View, CA 94043 Contact Person: Debera Brown Vice President, Regulatory and Clinical Affairs 2. Device Name: Trade Name: To Be Determined Common/Usual Name: Electrosurgical Electrode Classification Name: Electrosurgical Cutting and Coagulation Device and Accessories 3. Identification of the Predicate or Legally Marketed Devices to Which Equivalence is being Claimed: Electrosurgical Electrode by Premier Dental Products 4. Device Description: The Fusion Ball Tip Electrode is a reusable electrode for use in monopolar electrosurgical accessories. 5. Intended Use: Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended to provide electrocautery over a large surface. {1} 047 6. A Statement of How the Technological Characteristics of the Device Compare to Those of the Predicate or Legally Marketed Device. | Parameter | Fusion Ball Tip Electrode | Premier Dental Electrode K923332 | | --- | --- | --- | | Indications for Use | Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended to provide electrocautery over a large surface. | Intended for use by practitioners in a manner identical to similar electrosurgical electrodes of this type presently in commercial distribution. It is intended for cutting and coagulation of tissue. | | Use Profile | Provided Sterile; reusable after cleaning and autoclave sterilization | Provided non-sterile; first use and reuse after autoclave or ETO sterilization | | Compatibility | Standard 3/32 inch (2.4 mm) shaft fits most electrosurgery chucks and pencils | 44 different configurations provided, all standard 3/32 shaft to fit most electrosurgery chucks and pencils | | Material Composition | Stainless Steel shank, Polyphenylsulfone for insulation, 99% Pure Silver as electrode tip | Stainless Steel shank, Korvex 4X Teflon TFE heat shrinkable tubing, Type 304 stainless steel electrode tip | | Sterilization | Provided sterile by gamma irradiation for first use | Provided non-sterile, must be sterilized by user before first use | | Biocompatibility | Materials used in other medical devices; ISO 10993-1 | Materials used in other devices |
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...