ELECSYS CALCHECK PSA
Device Facts
| Record ID | K970458 |
|---|---|
| Device Name | ELECSYS CALCHECK PSA |
| Applicant | Boehringer Mannheim Corp. |
| Product Code | JJX · Clinical Chemistry |
| Decision Date | Mar 6, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.1660 |
| Device Class | Class 1 |
Intended Use
The Boehringer Mannheim Elecsys CalCheck PSA is used to verify the calibration assignment for the Boehringer Mannheim Elecsys PSA assay.
Device Story
Elecsys CalCheck PSA consists of three-level lyophilized, human-based materials; used to verify calibration assignment for Elecsys PSA assay. Device requires reconstitution; assayed in triplicate; results compared to target values. Used in clinical laboratory settings by laboratory personnel. Output provides verification of assay calibration accuracy, ensuring reliable patient PSA test results.
Clinical Evidence
No clinical data. Performance characteristics based on value assignment and stability testing.
Technological Characteristics
Three-level lyophilized, human-based material set. Matrix: Bovine serum albumin. Analyte: PSA. Intended for use with Elecsys PSA assay.
Indications for Use
Indicated for use as a calibration verification material for the Elecsys PSA assay to verify calibration assignment.
Regulatory Classification
Identification
A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls.
Predicate Devices
- Elecsys® CalCheck™ TSH (K963147)
Related Devices
- K970452 — ELECSYS CALCHECK CEA · Boehringer Mannheim Corp. · Mar 6, 1997
- K970459 — ELECSYS CALCHECK CEA · Boehringer Mannheim Corp. · Mar 6, 1997
- K061139 — BAYER ADVIA IMS PSA CALIBRATOR AND ADVIA IMS CPSA CALIBRATORS · Bayer Healthcare, LLC · Jul 6, 2006
- K123127 — VALIDATE PSA CALIBRATION VERIFICATION/ LINEARITY TEST KIT MODEL 406 · Maine Standards Co. · Jun 14, 2013
- K131536 — IMMULITE 2000 PSA CALIBRATION VERIFICATION MATERIAL · Siemens Healthcare Diagnostics, Inc. · Aug 12, 2013