← Product Code [HNO](/productcode/HNO) · K970377

# PLANCON MICROLAMELLAR KERATOME (SINGLE PIECE KERATOME HEAD WITH ACCESSORIES) (K970377)

_Plancon Instruments · HNO · Mar 31, 1997 · Ophthalmic · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K970377

## Device Facts

- **Applicant:** Plancon Instruments
- **Product Code:** [HNO](/productcode/HNO.md)
- **Decision Date:** Mar 31, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 886.4370
- **Device Class:** Class 1
- **Review Panel:** Ophthalmic
- **Attributes:** Therapeutic

## Indications for Use

To perform microlamellar keratoplasty for the correction of myopia or hyperopia

## Device Story

The Plancon Instruments Microlamellar Keratome is a surgical instrument used by ophthalmologists to perform microlamellar keratoplasty. The system consists of a gas-powered turbine motor, a fixed single-piece keratome head, a keratome blade, pneumatic fixation rings, and applanation lenses. The device is powered by a vacuum pump unit that regulates gas pressure. During surgery, the pneumatic fixation ring secures the eye, and the keratome head, equipped with a blade, creates a lamellar corneal incision. The fixed-head design limits the cut depth to a single predetermined value, enhancing safety compared to adjustable-head models. The device is used in a clinical or surgical setting to facilitate refractive surgery, potentially improving patient vision by correcting myopia or hyperopia.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

System includes gas-powered turbine motor (0-20,000 RPM), stainless steel/titanium/aluminum construction, pneumatic fixation rings, and applanation lenses. Operates via gas pressure regulation. Fixed single-piece keratome head design. No gear system.

## Regulatory Identification

A keratome is an AC-powered or battery-powered device intended to shave tissue from sections of the cornea for a lamellar (partial thickness) transplant.

## Predicate Devices

- PLANCON INSTRUMENTS Microlamellar Keratome ([K960395](/device/K960395.md))
- EYE TECHNOLOGY (Not known)
- SCMD ([K935342](/device/K935342.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

MAR 31 1997
K970377

# SAFETY AND EFFECTIVENESS SUMMARY K970377 p. 1/2

Plancon Instruments, 15 Rue Georges Besse, 92160 Antony, France
Contact person: Mr. Alain DUPRAT, General Manager
Date: December 13, 1996
Tel.: (33-1) 46 74 46 74

|   | Predicated device ①
510 K Document number
K 960395 | Predicated device ②
510 document number :
Not known | Predicated device ③
510 K document number :
K 935342 | Submitted device  |
| --- | --- | --- | --- | --- |
|  Designation / Feature | PLANCON INSTRUMENTS
Microlamellar Keratome | EYE TECHNOLOGY | SCMD | PLANCON INSTRUMENTS
Microlamellar Keratome
(single piece head)  |
|  Intended use | To perform microlamellar keratoplasty for the correction of myopia or hyperopia | To perform micro lamellar keratoplasty for the correction of myopia or hyperopia | To perform micro lamellar keratoplasty for the correction of myopia or hyperopia | To perform microlamellar keratoplasty for the correction of myopia or hyperopia  |
|  System composition | Power unit
Turbine motor
Adjustable keratome head
Keratome blade
Pneumatic fixation rings
Applanation lenses
Plate checking gauge | Power unit
Turbine motor
Adjustable keratome head
Keratome blade
Pneumatic fixation rings
Applanation lenses
Plate checking gauge | Power unit
Turbine motor
Adjustable keratome head
Keratome blade
Pneumatic fixation rings
Applanation lenses
Plate checking gauge | Power unit
Turbine motor
Fixed keratome head
Keratome blade
Pneumatic fixation rings
Applanation lenses  |
|  Power unit | Vacuum pump
Battery
Vacuum release valve
Knob to regulate gas pressure
Gas & vacuum pressure gauges
Vacuum & turbine quick connectors
Battery charger unit | Vacuum pump
Battery
Vacuum release valve
Knob to regulate gas pressure
Gas & vacuum pressure gauges
Vacuum & turbine quick connectors
Battery charger unit | Vacuum pump
Battery
Vacuum release valve
Knob to regulate gas pressure
Gas & vacuum pressure gauges
Vacuum & turbine quick connectors
Battery charger unit | Vacuum pump
Battery
Vacuum release valve
Knob to regulate gas pressure
Gas & vacuum pressure gauges
Vacuum & turbine quick connectors
Battery charger unit  |

{1}

K970377

SAFETY AND EFFECTIVENESS SUMMARY K970377 p. 2/2

|   | Predicated device ①
510 K Document number
K 960395 | Predicated device ②
510 document number :
Not known | Predicated device ③
510 K document number :
K 935342 | Submitted device  |
| --- | --- | --- | --- | --- |
|  Designation / Feature | PLANCON INSTRUMENTS
Microlamellar Keratome | EYE TECHNOLOGY | SCMD | PLANCON INSTRUMENTS
Microlamellar Keratome
(single piece head)  |
|  Turbine motor | Gas powered
Adjustable speed 0 to 20 000 RPM (recommended 14 000 RPM)
Material : stainless steel, titanium and aluminium.
No gear system | Gas powered
Adjustable speed
Material : stainless steel
No gear system | Gas powered
Adjustable speed from 10 to 24 000 RPM
Pre-set speed 14 000 RPM
Material : stainless steel and brass
No gear system | Gas powered
Adjustable speed 0 to 20 000 RPM (recommended 14 000 RPM)
Material : stainless steel, titanium and aluminium.
No gear system  |
|  Keratome | Material : stainless steel
Adjustable
Safety : maximum cut depth, and checking gauge | Material : stainless steel
Adjustable
Permanent adjustable head with adjustment knob
Safety : maximum cut depth and checking gauge | Material : stainless steel
Adjustable
Safety : maximum cut depth and checking gauge | Material : stainless steel
Fixed single piece head
Safety : only one cut depth allowed by head principle  |
|  Pneumatic fixation rings | Material : stainless steel
Double dovetails | Material : stainless steel
Double dovetails | Material : stainless steel
Double dovetails | Material : stainless steel
Double dovetails  |
|  Applanation lenses | Material : clear plastic + stainless handle
Engraved inner reticle diameter | Material : clear plastic + stainless handle
Engraved inner reticle diameter | Material : clear plastic + stainless handle
Engraved inner reticle diameter | Material : clear plastic + stainless handle
Engraved inner reticle diameter  |

---

**Source:** [https://fda.innolitics.com/device/K970377](https://fda.innolitics.com/device/K970377)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
