STRATUS MYOGLOBIN GLUOROMETRIC ENZYME IMMUNOASSAY
Device Facts
| Record ID | K965213 |
|---|---|
| Device Name | STRATUS MYOGLOBIN GLUOROMETRIC ENZYME IMMUNOASSAY |
| Applicant | Dade Intl., Inc. |
| Product Code | DDR · Immunology |
| Decision Date | Feb 10, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 866.5680 |
| Device Class | Class 2 |
Indications for Use
The Stratus® Myoglobin Fluorometric Enzyme Immunoassay is an in vitro diagnostic test for the quantitative measurement of myoglobin in human serum and heparinized plasma. Myoglobin measurements are used in the diagnosis and treatment of myocardial infarction.
Device Story
Fluorometric enzyme immunoassay for quantitative myoglobin measurement in human serum and heparinized plasma; used to aid myocardial infarction diagnosis. Device utilizes Stratus® system platform. Modification from predicate (K922125/A) involves addition of heparinized plasma as validated sample type. Clinicians use results to assess cardiac injury. Testing performed in laboratory setting.
Clinical Evidence
Bench testing only. Comparative performance study analyzed 101 patient samples in duplicate (serum vs. heparinized plasma). Results: correlation coefficient 0.98; regression equation y = 0.94x + 7.09. Performance deemed acceptable.
Technological Characteristics
Fluorometric enzyme immunoassay; quantitative measurement; compatible with Stratus® system instrumentation. Sample types: serum and heparinized plasma.
Indications for Use
Indicated for the quantitative measurement of myoglobin in human serum and heparinized plasma to aid in the diagnosis and treatment of myocardial infarction.
Regulatory Classification
Identification
A myoglobin immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the myoglobin (an oxygen storage protein found in muscle) in serum and other body fluids. Measurement of myoglobin aids in the rapid diagnosis of heart or renal disease.
Predicate Devices
- Stratus® Myoglobin Fluorometric Enzyme Immunoassay (K922125/A)
Related Devices
- K972782 — DADE STRATUS CK-MB FLUOROMETRIC ENZYME IMMUNOASSAY · Dade Intl., Inc. · Aug 15, 1997
- K981102 — STRATUS CS MYOGLOBIN (MYO) TESTPAK · Dade Behring, Inc. · Apr 27, 1998
- K973126 — TRIAGE CARDIAC PANEL, TRIAGE TROPONIN-I, TRIAGE CK-MB, TRIAGE MYOGLOBIN, TRIAGE TROPONIN-I AND CK-MB, TRIAGE TROPONIN-I · Biosite Incorporated · Oct 6, 1997
- K981012 — AIA-PACK MYOGLOBIN ASSAY · Tosoh Medics, Inc. · May 28, 1998
- K972094 — TARGET CARDIAC TROPONIN I TEST · Texas Immunology, Inc. · Jul 23, 1997