LIQUICHEK URIANLYSIS CONTROL (CAT. NO. 420,421,422,425,426)

K965171 · Bio-Rad · JJY · Jan 13, 1997 · Clinical Chemistry

Device Facts

Record IDK965171
Device NameLIQUICHEK URIANLYSIS CONTROL (CAT. NO. 420,421,422,425,426)
ApplicantBio-Rad
Product CodeJJY · Clinical Chemistry
Decision DateJan 13, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1660
Device ClassClass 1

Indications for Use

Liquichek Urinalysis Control is intended for use as an assayed quality control urine to monitor the precision of laboratory dipstick and microscopic testing procedures for the analytes listed in the package insert.

Device Story

Liquichek Urinalysis Control is a liquid-form quality control product derived from human urine, supplemented with human erythrocytes, leukocytes, non-human constituents, and pure chemicals. Used in clinical laboratory settings by technicians to monitor the precision of urinalysis dipstick and microscopic testing procedures. The control provides a known reference point to verify the performance of analytical methods. By ensuring the accuracy and precision of these tests, the device assists healthcare providers in maintaining reliable diagnostic results for patient urinalysis, ultimately supporting clinical decision-making regarding patient health status.

Clinical Evidence

Bench testing only. No clinical data provided.

Technological Characteristics

Liquid-form control matrix derived from human urine; contains human erythrocytes, leukocytes, and chemical constituents. Level 2 contains 0.1% sodium azide preservative. Storage at 2-8°C. Open vial stability: 2-8°C for 30 days/10 immersions or 18-25°C for 7 days/10 immersions.

Indications for Use

Indicated for use as an assayed quality control material for laboratory personnel to monitor the precision of urinalysis dipstick and microscopic testing procedures.

Regulatory Classification

Identification

A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls.

Predicate Devices

Submission Summary (Full Text)

{1} BIO-RAD Bio-Rad Laboratories ECS Division 3726 E. Miraloma Avenue Anaheim, CA 92806 Telephone (714) 630-6400 Toll Free (800) 854-6737 K965171 JAN 13 1997 # 510(k) Summary ## Submitter Bio-Rad Laboratories, ECS Division 3726 E. Miraloma Avenue Anaheim, CA 92806 (714)630-6400 Fax (714)666-1383 ## Contact Person Elizabeth Platt ## Date of Summary Preparation December 19, 1996 ## Device (Trade & Common Name) Liquichek Urinalysis Control ## Classification Name CFR 862.1660: Urinalysis Controls (Assayed and Unassayed) ## Devices to Which Substantial Equivalence is Claimed Liquid Urine Control Kenlor Industries Westminster, CA K890577 ## Statement of Intended Use Liquichek Urinalysis Control is intended for use as an assayed quality control urine to monitor the precision of laboratory dipstick and microscopic testing procedures for the analytes listed in the package insert. {2} BIO-RAD Bio-Rad Laboratories ECS Division 3726 E. Miraloma Avenue Anaheim, CA 92806 Telephone (714) 630-6400 Toll Free (800) 854-6737 ## Description of the Device Liquichek Urinalysis Control is prepared from human urine with added human erythrocytes, leukocytes and constituents of non-human origin and pure chemicals. The control is provided in liquid form for convenience. Level 2 of this product contains 0.1% sodium azide as a preservative. ## Statement of How Technological Characteristics Compare to Substantial Equivalence Device A table is provided below comparing the similarities between the Bio-Rad Liquichek Urinalysis Control and the devices to which substantial equivalence is claimed. | | Bio-Rad Liquichek Urinalysis Control | Liquid Urine Control Kenlor Industries | | --- | --- | --- | | Intended Use | an assayed quality control urine to monitor the precision of laboratory dipstick and microscopic testing procedures for the analytes listed in the package insert | for monitory the accuracy and precision of dipstick and microscopic analysis | | Form | Liquid | Liquid | | Matrix | Human Urine | Human Urine | | Storage | 2-8°C | 2-8°C | | Open Vial Claim | 2-8°C for 30 days or 10 immersions; 18-25°C for 7 days or 10 immersions | 2-8°C for 2 weeks or 15 immersions; room temperature for 2 weeks or 10 immersions |
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...