ELC 35-UP MODEL NUMBER 116015 AND ELC 54-UP MODEL NUMBER 115606
K965106 · Biotronik, Inc. · DTB · Jan 27, 1998 · Cardiovascular
Device Facts
Record ID
K965106
Device Name
ELC 35-UP MODEL NUMBER 116015 AND ELC 54-UP MODEL NUMBER 115606
Applicant
Biotronik, Inc.
Product Code
DTB · Cardiovascular
Decision Date
Jan 27, 1998
Decision
PT
Submission Type
Traditional
Regulation
21 CFR 870.3680
Device Class
Class 3
Attributes
Therapeutic, Real-World Evidence, Pediatric
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K965106 · Jan 27, 1998
ELC 35-UP MODEL NUMBER 116015 AND ELC 54-UP MODEL NUMBER 115606
Biotronik, Inc.
Worldwide commercial distribution and complaint records
The sponsor utilized worldwide post-market sales data and complaint monitoring to support the safety profile of the ELC lead, noting over 2000 leads distributed with no reported device failures or complaints.
Post-market surveillance; Commercial distribution data; Complaint monitoring
Clinical Evidence
Study Design
Population
Comparator
Key Endpoints
Worldwide commercial distribution; Post-market surveillance / Commercial monitoring; Follow-up/Duration: March 1994 to December 1996; Study Period: 1994-1996
Patients implanted with ELC leads worldwide; Sample Size: >2000 leads; Number of Sites: Not applicable
Not applicable for this study
Device failures and complaints
Indications for Use
The ELC xx-UP epicardial sutureless screw-in lead is indicated for unipolar pacing and sensing in the ventricle when an epicardial lead is preferred, or when a transvenous lead cannot provide satisfactory results or is contraindicated. Epicardial leads are well suited for situations where heart stimulation is necessary, for example, after open heart surgery, or based upon the patient's age or heart condition (e.g., in young patients who have not reached full physical maturity and risk potential lead dislodgement). Epicardial leads are also indicated in situations where transvenous access is not available or is contraindicated.
Device Story
ELC epicardial sutureless active fixation lead; unipolar pacing/sensing lead for implantable cardiac pacemakers. Features helically-wound fixation screw (70% platinum/30% iridium) with fractal-surfaced, ball-like microstructure via PVD treatment; lead body uses NuSil MED-4750 silicone rubber tubing; quadrafilar MP35N wire conductor. IS-1 (3.2 mm) connection system. Used in clinical settings (e.g., post-open heart surgery) by physicians when transvenous leads are contraindicated or ineffective. Provides long-term pacing; fixation screw secures lead to myocardium. Potential complications include electrode dislodgement, lead fracture, or fibrotic tissue formation affecting thresholds. Clinical benefit: reliable cardiac stimulation in patients where traditional transvenous approaches are unsuitable.
Clinical Evidence
Bench testing included biocompatibility, acute/chronic implantation studies, corrosion testing of PVD iridium, weld strength, fatigue strength, DC resistance, and environmental resistance. Clinical data includes worldwide experience (over 2000 leads) and a US clinical trial (18 implants) under IDE #G960045; all leads functioned normally except one case of suspected dislodgement.
Technological Characteristics
Unipolar epicardial lead; IS-1 (3.2 mm) connection per ISO 5841.3:1992. Materials: NuSil MED-4750 silicone rubber tubing, quadrafilar MP35N wire conductor, 70% platinum/30% iridium fixation screw with PVD-treated fractal surface. Mechanical fixation via screw-in mechanism.
Indications for Use
Indicated for patients requiring ventricular unipolar pacing and sensing where epicardial access is preferred or transvenous access is contraindicated or unsuccessful. Suitable for post-open heart surgery patients and pediatric patients at risk of transvenous lead dislodgement.
Regulatory Classification
Identification
Temporary pacemaker electrode: A device consisting of flexible insulated electrical conductors with one end connected to an external pacemaker pulse generator and the other end applied to the heart. The device is used to transmit a pacing electrical stimulus from the pulse generator to the heart and/or to transmit the electrical signal of the heart to the pulse generator. Permanent pacemaker electrode: A device consisting of flexible insulated electrical conductors with one end connected to an implantable pacemaker pulse generator and the other end applied to the heart. The device is used to transmit a pacing electrical stimulus from the pulse generator to the heart and/or to transmit the electrical signal of the heart to the pulse generator.
Reference Devices
Physios CTM 01 Cardiac Transplant Monitoring System (IDE #G960045)
Submission Summary (Full Text)
{1}
K965106
ELC Lead - 510(k)
# 1.4 Safety and Effectiveness Summary
JAN 27 1998
The BIOTRONIK ELC xx-UP epicardial sutureless active fixation lead is a safe and effective unipolar lead used with implantable cardiac pacemakers when an epicardial lead is preferred, or when a transvenous lead cannot provide satisfactory results or is contraindicated. The lead body insulation of all ELC epicardial leads is NuSil MED-4750 silicone rubber tubing, with a conductor of quadrafilar MP35N wire.
These leads provide long-term safe and effective pacing through overall quality of design, manufacture and the surface structure of the active-fixation electrode tip. This tip is a single helically-wound fixation wire (“fixation screw”) composed of 70% platinum and 30% iridium which has undergone a Physical Vapor Deposition (PVD) treatment, creating a fractal-surfaced, ball-like microstructure. The IS-1 (3.2 mm) connection system of the ELC lead complies with the International Standard ISO 5841.3:1992.
The materials used to manufacture the ELC leads which come into contact with the patient are commonly used in market-released leads, and have been tested for biocompatibility. Acute and chronic biocompatibility tests have been performed, as well as long-term implantation studies. In addition, corrosion studies were completed to address both long-term toxicity and durability of the PVD iridium treatment. The testing conducted for biocompatibility as well as extensive clinical experience confirms that iridium is safe for use as an implantable material, and analyses supporting this view have been published within technical journals. Long-term corrosion testing results substantiate that iridium is a non-toxic and durable material for use in implantable devices.
Additional qualification testing results validate the safety and effectiveness of the lead design and materials used. ELC leads are tested for weld strength of connections, fatigue strength, DC resistance, environmental resistance, adherence to IS-1 standards, packaging and transportation durability, electrical integrity, and sterilization validation. All test results were within specifications.
Field clinical experience as well as the in-vitro and qualification testing performed on the ELC lead show that the risk to the patient in using these leads is the same as that of any implantable epicardial lead.
Potential complications resulting from the use of epicardial leads include, but are not limited to: thombosis, embolism, body rejection phenomena, cardiac tamponade, muscle/nerve stimulation, fibrillation, and infection. Lead perforation through the myocardium has been rarely observed.
BIOTRONIK, December 17, 1996
{2}
ELC Lead - 510(k)
Table 2.0 below summarizes some of the potential symptoms indicating a complication and possible corrective actions:
Table 2.0
Lead Complications
| SYMPTOM | POTENTIAL COMPLICATION | POTENTIAL CORRECTIVE ACTION |
| --- | --- | --- |
| Loss of pacing or sensing | • Electrode dislodgement
• Lead fracture
• Setscrew penetration of lead insulation
• Improper lead to pacemaker connection | • Reposition lead
• Replace lead
• Replace lead
• Reconnect lead to pacemaker |
| Increase or decrease in threshold | • Fibrotic tissue formation | • Adjust pulse generator output; Reposition lead |
The ELC lead received its CE mark in March, 1994, thereby clearing it for sale and distribution within the EEC. Since that date, over 2000 leads have been sold worldwide outside the United States, including 426 sold in 1996 (excluding December). There have been no reported device failures or complaints.
As of December 5, 1996, eighteen (18) leads have been implanted in the United States as part of a clinical trial with the Physios CTM 01 Cardiac Transplant Monitoring System (IDE #G960045; approved August 22, 1996).
All leads are functioning normally, with the exception of one which has been reported as an anticipated adverse event for the study - failing to yield consistent ventricular capture, potentially because of lead dislodgement.
BIOTRONIK, December 17, 1996
{3}
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration
9200 Corporate Boulevard
Rockville MD 20850
Mr. Kenneth Jensen
BIOTRONIK Regulatory Affairs
BIOTRONIK, Inc.
6024 Jean Road
Lake Oswego, OR 97035-5369
Re: K965106
Epicardial Pacing Leads, Models ELC 35 UP, ELC 54 UP
Regulatory Class: III (THREE)
Product Code: DTB
Dated: December 24, 1997
Received: December 29, 1997
Dear Mr. Jensen:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments. You may, therefore, market the device, subject to the general controls provisions of the Federal Food, Drug, and Cosmetic Act (act). The general controls provisions of the act include requirements for registration, listing of devices, good manufacturing practices, and labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval) it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, FDA will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, the Food and Drug Administration (FDA) may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under section 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulation.
JAN 27 1998
{4}
Page 2 - Mr. Kenneth Jensen
Under Section 522(a) of the act, manufacturers of certain types of devices identified by the Act or designated by FDA are required to conduct postmarket surveillance studies. FDA has identified under Section 522(a)(1)(A) the device cleared for marketing by this letter as requiring postmarket surveillance.
Within thirty (30) days of first introduction or delivery for introduction of this device into interstate commerce you are required to submit to FDA certification of the date of introduction into interstate commerce, a detailed protocol which describes the postmarket surveillance study, and a detailed profile of the study's principal investigator that clearly establishes the qualifications and experience of the individual to conduct the proposed study. For your information, general guidance on preparing a protocol for a postmarket surveillance study is attached.
Submit five (5) copies to:
Center for Devices and Radiological Health
Postmarket Surveillance Studies Document Center
Room 3083 (HFZ-544)
1350 Piccard Drive
Rockville, Maryland 20850
Within sixty (60) days of receipt of your protocol, FDA will either approve or disapprove it and notify you of the Agency's action in writing. You should not begin your postmarket surveillance study of this device until the protocol has been approved. Data generated under an unapproved protocol may not satisfy your obligation under section 522. Please note that you must continue to collect and report data needed to maintain compliance with Medical Device Reporting regulations (21 CFR 803).
Failure to certify accurately the date of initial introduction of your device into interstate commerce, to submit timely an acceptable protocol, or to undertake and complete and FDA approved postmarket surveillance study consistent with the protocol will be considered violations of section 522. In accordance with the Medical Device Amendments of 1992, failure of a manufacturer to meet its obligations under section 522 is a prohibited act under section 301(q)(1)(C) of the Act (21 U.S.C. 331 (q)(1)(C)). Further, under section 502(t)(3) of the act (21 U.S.C. 352(t)(3)), a device is misbranded if there is a failure or refusal to comply with any requirement under section 522 of the act. Violations of sections 301 or 502 may lead to regulatory actions including seizure of your product, injunction, prosecution, or civil money penalties.
{5}
Page 3 - Mr. Kenneth Jensen
If you have questions specifically concerning postmarket surveillance study requirements, contact the Postmarket Surveillance Studies Branch at (301) 594-0639.
In addition, on August 16, 1993, the Final Rule for Device Tracking was published in the *Federal Register*, pages 43442-43455 (copy enclosed). Be advised that under Section 519(e) of the Act as amended by the Safe Medical Devices Act of 1990, FDA has identified the above device as a device which requires tracking. Because the device is subject to tracking, you are required to adopt a method of tracking that follows the devices through the distribution chain and then identifies and follows the patients who receive them. The specific requirement of the regulation are found in 21 CFR 821 as described in the August 16, 1993 *Federal Register* beginning on page 43447.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809 for *in vitro* diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Other general information on your responsibilities under the act may be obtained from the Division of Small Manufacturers Assistance at its toll free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,

Thomas J. Callahan, Ph.D.
Director
Division of Cardiovascular, Respiratory, and Neurological Devices
Office of Device Evaluation
Center for Devices and Radiological Health
Enclosures
{6}
Page 1 of 1
510(k) Number (if known): K965106
Device Name: ELC Epicardial Leads
Indications For Use:
The ELC xx-UP epicardial sutureless screw-in lead is indicated for unipolar pacing and sensing in the ventricle when an epicardial lead is preferred, or when a transvenous lead cannot provide satisfactory results or is contraindicated. Epicardial leads are well suited for situations where heart stimulation is necessary, for example, after open heart surgery, or based upon the patient's age or heart condition (e.g., in young patients who have not reached full physical maturity and risk potential lead dislodgement). Epicardial leads are also indicated in situations where transvenous access is not available or is contraindicated.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Brad C. Cato / J. Z. Z. (Division Sign-Off)
Division of Cardiovascular, Respiratory, and Neurologic Services
510(k) Number K965106
Prescription Use: ☑ (Per 21 CFR 801.109)
OK
Over-The-Counter Use: ☐ (Optional Format 1-2-96)
333
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.