RESTRICTIVE LIMB HOLDER
Device Facts
| Record ID | K963468 |
|---|---|
| Device Name | RESTRICTIVE LIMB HOLDER |
| Applicant | Deroyal Industries, Inc. |
| Product Code | FMQ · General Hospital |
| Decision Date | Jan 22, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 880.6760 |
| Device Class | Class 1 |
Indications for Use
The DeRoyal Industries, Inc. Restrictive Limb Holder is indicated for use, at the discretion of a responsible licensed healthcare professional, to substantially limit patient limb movements thereby enabling examination or protection of the patient or others. The Restrictive Limb Holder can be used with a gurney, bed, or stretcher.
Device Story
Protective restraint device; limits limb movement for patient/staff safety during examination. Comprised of leather, neoprene, soft kodel, and webbing straps; utilizes hook and loop, delrin, and steel nickel-plated fasteners. Universal size; attaches to gurneys, beds, or stretchers. Operated by healthcare professionals; requires 24-hour prescription renewal. Benefits include controlled patient movement in clinical settings.
Clinical Evidence
Bench testing only.
Technological Characteristics
Materials: leather, neoprene, soft kodel, nylon/polyester webbing. Fasteners: hook and loop, delrin, steel nickel-plated. Form factor: universal size limb restraint. Energy source: none (mechanical).
Indications for Use
Indicated for highly agitated or violent patients requiring limb movement restriction to facilitate medical examination or ensure safety of patient/others. Use requires prescription by a licensed healthcare professional every 24 hours.
Regulatory Classification
Identification
A protective restraint is a device, including but not limited to a wristlet, anklet, vest, mitt, straight jacket, body/limb holder, or other type of strap, that is intended for medical purposes and that limits the patient's movements to the extent necessary for treatment, examination, or protection of the patient or others.
Predicate Devices
- J.T. Posey Company (not specified)
- DeRoyal Industries, Inc. (not specified)
Related Devices
- K963473 — REUSABLE LIMB HOLDER · Deroyal Industries, Inc. · Nov 14, 1996
- K963476 — DISPOSABLE LIMB HOLDER · Deroyal Industries, Inc. · Jan 22, 1997
- K963466 — PEDIATRIC LIMB HOLDER · Deroyal Industries, Inc. · Feb 13, 1997
- K963474 — TUXEDO VEST RESTRAINT · Deroyal Industries, Inc. · Jan 22, 1997
- K963475 — PONCHO VEST RESTRAINT · Deroyal Industries, Inc. · Jan 22, 1997