← Product Code [GEI](/productcode/GEI) · K963338

# UNIMED SUCTION-IRRIGATION ELECTRODE AND SLIDING SHEATH (K963338)

_Unimed Surgical Products, Inc. · GEI · Oct 21, 1996 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K963338

## Device Facts

- **Applicant:** Unimed Surgical Products, Inc.
- **Product Code:** [GEI](/productcode/GEI.md)
- **Decision Date:** Oct 21, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4400
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

The unimed Surgical Products unimed Suction-Irrigation Electrode and unimed Sliding Sheath are electrosurgical devices designed for suction/irrigation as well as cutting and coagulating of soft tissue.

## Device Story

Electrosurgical device for suction, irrigation, cutting, and coagulation of soft tissue; features five tip configurations (Spatula, J-Hook, L-Hook, Coagulator, Needle); 5mm shaft diameter; 28cm or 32cm working lengths; proximal end connects to standard monopolar cord; used by surgeons in clinical settings; provides simultaneous fluid management and electrosurgical tissue interaction; facilitates surgical site visualization and hemostasis.

## Clinical Evidence

Bench testing only; no clinical data provided.

## Technological Characteristics

Electrosurgical device; non-toxic materials; 5mm shaft diameter; 28cm/32cm lengths; monopolar connectivity; five interchangeable tip configurations (Spatula, J-Hook, L-Hook, Coagulator, Needle).

## Regulatory Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

## Reference Devices

- Cabot Medical Suction-Irrigation Electrodes
- American Hydro-Surgical Instruments Suction-Irrigation Electrodes

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K 96 3338

OCT 21 1996

# SAFETY AND EFFECTIVENESS SUMMARY

**COMMON/USUAL NAME:** Electrosurgical Electrodes

**PROPRIETARY NAME:** *unimed* Suction-Irrigation Electrode and *unimed* Sliding Sheath

**CLASSIFICATION:** CLASS II

**MATERIALS:** All materials used to manufacture the *unimed* Suction-Irrigation Electrode and *unimed* Sliding Sheath are non-toxic and have been used in other previously marketed devices.

**DESCRIPTION:** The *unimed* Surgical Products *unimed* Suction-Irrigation Electrode and *unimed* Sliding Sheath are electrosurgical devices designed for suction/irrigation as well as cutting and coagulating of soft tissue.

*unimed* Surgical Products intends to market the *unimed* Suction-Irrigation Electrode with five tip configurations. The tip configurations are the Spatula, J-Hook, L-Hook, Coagulator and Needle. The electrodes are available with a shaft diameter of 5mm and a working length of 28cm or 32 cm. The *unimed* Sliding Sheath will be marketed in one configuration in 28cm and 32cm lengths. The proximal end is designed to fit a standard monopolar cord.

**SUBSTANTIAL EQUIVALENCE:** The *unimed* Suction-Irrigation Electrodes and *unimed* Sliding Sheath are similar to other Suction-Irrigation Electrodes currently commercially available. Numerous electrodes with a variety of tip configurations are marketed by Cabot Medical and American Hydro-Surgical Instruments.

---

**Source:** [https://fda.innolitics.com/device/K963338](https://fda.innolitics.com/device/K963338)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
