STEALTHSTATION SYSTEM

K963173 · Surgical Navigation Technologies, Inc. · HAW · Oct 25, 1996 · Neurology

Device Facts

Record IDK963173
Device NameSTEALTHSTATION SYSTEM
ApplicantSurgical Navigation Technologies, Inc.
Product CodeHAW · Neurology
Decision DateOct 25, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.4560
Device ClassClass 2

Device Story

StealthStation™ System; surgical navigation device. Submission adds STERRAD® Sterilization System as validated reprocessing option for specific system components. Validation performed by independent lab per AAMI TIR No. 12-1994 guidelines for reusable medical devices.

Clinical Evidence

Bench testing only; validation of sterilization process performed by independent laboratory in accordance with AAMI TIR No. 12-1994.

Technological Characteristics

Reusable medical device components; sterilization via STERRAD® Sterilization System; validation per AAMI TIR No. 12-1994.

Regulatory Classification

Identification

A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system.

Reference Devices

Submission Summary (Full Text)

{0} K963173 OCT 25 1996 510(k) Summary of Safety and Effectiveness StealthStation™ System Sterilization I. Company: Surgical Navigation Technologies 530 Compton St. Broomfield, CO 80020 (303) 439-9709 II. Product Name: StealthStation™ System III. This submission describes the addition of the STERRAD®* Sterilization System as a sterilization option for certain components of the StealthStation™ System which was cleared in a previous 510(k) submission. This sterilization option was validated by an independent laboratory in accordance with the AAMI TIR No. 12-1994, Designing, Testing and Labeling Reusable Medical Devices for Reprocessing in Health Care Facilities: A Guide for Device Manufacturers. *STERRAD is a registered trademark of Advanced Sterilization Products, a Division of Johnson and Johnson Medical, Inc.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...