← Product Code [MNH](/productcode/MNH) · K962645

# ISOLA TWISTER CONNECTOR (K962645)

_Acromed Corp. · MNH · Oct 22, 1996 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K962645

## Device Facts

- **Applicant:** Acromed Corp.
- **Product Code:** [MNH](/productcode/MNH.md)
- **Decision Date:** Oct 22, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3070
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The ISOLA Spinal System, when used with pedicle screws, is intended for use in grade 3 or 4 spondylolisthesis at the fifth lumbar - first sacral vertebral (L5-S1) joint utilizing autologous bone graft and intended to be removed after solid fusion is attained. Benefit of spinal fusions utilizing any pedicle screw fixation has not been adequately established in patients with stable spines. Potential risks identified with the use of this device system, which may require additional surgery, include: device component fracture, loss of fixation, non-union, fracture of the vertebra, neurological injury, and vascular or visceral injury. The ISOLA Spinal System, when not used with pedicle screws, is intended for hook, wire, and/or sacral/iliac screw fixation from T1 to the ilium/sacrum. The non-pedicle screw indications are spondylolisthesis, degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), deformities (scoliosis, lordosis and kyphosis), tumor, fracture and previous failed surgery. As a whole, the ISOLA Spinal System is intended for T1-sacral fixation. Screw fixation is from L3-S1. Contraindications for the use of the ISOLA System include active systemic infection or infection localized to the site of the proposed implantation. Severe osteoporosis may prevent adequate fixation of spinal anchors and thus preclude the use of this or any other posterior spinal instrumentation system. Any entity or condition that totally precludes the possibility of fusion, i.e., cancer, kidney dialysis, or osteopenia are relative contraindications. Other relative contraindications include obesity, certain degenerative diseases, and foreign body sensitivity. In addition, the patient's occupation or activity level or mental capacity may be relative contraindications to this surgery. Specifically, patients who because of their occupation or lifestyle, or because of conditions such as mental illness, alcoholism or drug abuse, may place undue stresses on the implant.

## Device Story

ISOLA Twister Connector is a two-piece spinal fixation component used within the ISOLA Spinal System. It features a slotted transverse member with splines that mate with a V-groove body, allowing for intraoperative sagittal alignment in 7-degree increments. The slotted design provides surgical latitude for pedicle screw placement; the screw is locked to the connector via a nut. Used by surgeons in spinal fusion procedures to stabilize the spine from T1 to the sacrum. The device provides mechanical stabilization to facilitate bone fusion; it is intended for removal after solid fusion is achieved.

## Clinical Evidence

Bench testing only. Static and fatigue testing performed to demonstrate mechanical performance consistent with previously cleared components.

## Technological Characteristics

Two-piece connector assembly consisting of a slotted transverse member and V-groove body with spline interface. Material: ASTM F-138 stainless steel. Allows 7-degree sagittal alignment increments. Mechanical fixation via nut-and-bolt assembly.

## Regulatory Identification

(1) Rigid pedicle screw systems are comprised of multiple components, made from a variety of materials that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of screws, longitudinal members (e.g., plates, rods including dual diameter rods, plate/rod combinations), transverse or cross connectors, and interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors).(2) Semi-rigid systems are defined as systems that contain one or more of the following features (including but not limited to): Non-uniform longitudinal elements, or features that allow more motion or flexibility compared to rigid systems.

## Special Controls

*Classification.* (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:(i) Compliance with material standards;
(ii) Compliance with mechanical testing standards;
(iii) Compliance with biocompatibility standards; and
(iv) Labeling that contains these two statements in addition to other appropriate labeling information:
 “Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.”
“Precaution: The implantation of pedicle screw spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this pedicle screw spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.”
(2) Class II (special controls), when a rigid pedicle screw system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion in the treatment of degenerative disc disease and spondylolisthesis other than either severe spondylolisthesis (grades 3 and 4) at L5-S1 or degenerative spondylolisthesis with objective evidence of neurologic impairment. These pedicle screw systems must comply with the following special controls:
(i) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use.
(ii) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant.
(iii) Device components must be demonstrated to be biocompatible.
(iv) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments.
(v) Labeling must include the following:
(A) A clear description of the technological features of the device including identification of device materials and the principles of device operation;
(B) Intended use and indications for use, including levels of fixation;
(C) Identification of magnetic resonance (MR) compatibility status;
(D) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user; and
(E) Detailed instructions of each surgical step, including device removal.
(3) Class II (special controls), when a semi-rigid system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion for any indication. In addition to complying with the special controls in paragraphs (b)(2)(i) through (v) of this section, these pedicle screw systems must comply with the following special controls:
(i) Demonstration that clinical performance characteristics of the device support the intended use of the product, including assessment of fusion compared to a clinically acceptable fusion rate.
(ii) Semi-rigid systems marketed prior to the effective date of this reclassification must submit an amendment to their previously cleared premarket notification (510(k)) demonstrating compliance with the special controls in paragraphs (b)(2)(i) through (v) and paragraph (b)(3)(i) of this section.

## Predicate Devices

- AcroMed Slotted Connectors

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K962645

# ISOLA SYSTEM

# ISOLA Twister Connector

# 510(k) SUMMARY

OCT 22 1996

## COMPANY:
AcroMed Corporation
3303 Carnegie Avenue
Cleveland, OH 44115

## TRADENAME:
ISOLA Twister Connector
used with the ISOLA System

## CLASSIFICATION:
Labeled for pedicle screw use:
Spondylolisthesis spinal fixation device system;
Unclassified, preamendments device system

Labeled for previously cleared uses:
Spinal interlaminal fixation orthosis;
Class II

## DESCRIPTION:
The two piece Twister connector design utilizes the attributes of the one piece slotted connectors. It consists of a slotted transverse member with splines which mate with the splines of the V Groove body. Together these two pieces create the slotted connector assembly. The spline connection or joint is the medium by which the screw/connector interface can be manipulated and secured. This two piece design allows for intraoperative sagittal alignment in 7° increments.

The slotted portion of each design provides further surgical latitude for placement of the screw. The machine threaded portion of the screw is locked to the connector with a nut.

## MATERIAL:
All implant components are manufactured of ASTM F-138 stainless steel.

61/0 '1 0000 '0N

WJ17:21 0001 '01 '00

{1}

# INDICATIONS:

The ISOLA Spinal System, when used with pedicle screws, is intended for use in grade 3 or 4 spondylolisthesis at the fifth lumbar - first sacral vertebral (L5-S1) joint utilizing autologous bone graft and intended to be removed after solid fusion is attained.

Benefit of spinal fusions utilizing any pedicle screw fixation has not been adequately established in patients with stable spines.

Potential risks identified with the use of this device system, which may require additional surgery, include: device component fracture, loss of fixation, non-union, fracture of the vertebra, neurological injury, and vascular or visceral injury.

The ISOLA Spinal System, when not used with pedicle screws, is intended for hook, wire, and/or sacral/iliac screw fixation from T1 to the ilium/sacrum. The non-pedicle screw indications are spondylolisthesis, degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), deformities (scoliosis, lordosis and kyphosis), tumor, fracture and previous failed surgery.

As a whole, the ISOLA Spinal System is intended for T1-sacral fixation. Screw fixation is from L3-S1.

Contraindications for the use of the ISOLA System include active systemic infection or infection localized to the site of the proposed implantation. Severe osteoporosis may prevent adequate fixation of spinal anchors and thus preclude the use of this or any other posterior spinal instrumentation system.

Any entity or condition that totally precludes the possibility of fusion, i.e., cancer, kidney dialysis, or osteopenia are relative contraindications. Other relative contraindications include obesity, certain degenerative diseases, and foreign body sensitivity. In addition, the patient's occupation or activity level or mental capacity may be relative contraindications to this surgery. Specifically, patients who because of their occupation or lifestyle, or because of conditions such as mental illness, alcoholism or drug abuse, may place undue stresses on the implant.

61/9 'd 0990 '0N
WJLZ:ZI 9661 '81 '120

{2}

Oct. 18, 1996 12:27PM
No. 066U  F. 1/19

PERFORMANCE
DATA:

Static and fatigue testing shows the constructs of the ISOLA Twister Connector to perform consistently with previously cleared components.

SUBSTANTIAL
EQUIVALENCE:

The ISOLA Twister Connector is equivalent to other AcroMed Slotted Connectors in intended use and attachment.

---

**Source:** [https://fda.innolitics.com/device/K962645](https://fda.innolitics.com/device/K962645)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
