RODENSTOCK SLITLAMP (MODEL 5000 & 4000)
Device Facts
| Record ID | K962532 |
|---|---|
| Device Name | RODENSTOCK SLITLAMP (MODEL 5000 & 4000) |
| Applicant | Expertech Assoc., Inc. |
| Product Code | HJO · Ophthalmic |
| Decision Date | Jul 25, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 886.1850 |
| Device Class | Class 2 |
Intended Use
The device and accessories are indicated as a noninvasive aid in the examination and diagnosis of eye conditions and in the fitting of contact lenses.
Device Story
Rodenstock RO 5000 and RO 4000 slitlamps; instruments for eye examination and contact lens fitting. Device integrates microscope with adjustable light source to create slit illumination of eye. Accessories enable measurement of eye characteristics and documentation of ocular shapes. Used in clinical settings by eye care professionals. Provides magnified visualization of ocular structures to assist in diagnosis and contact lens fitting.
Clinical Evidence
No clinical data; bench testing only. Substantial equivalence based on technological characteristics and intended use identical to predicate devices.
Technological Characteristics
AC-powered slitlamp biomicroscope; 6.3 to 12v AC, 50-60 Hz power source. Consists of microscope and adjustable slit light source. Supports standard ophthalmic accessories for tonometry, vitreous/fundus examination, and contact lens fitting.
Indications for Use
Indicated for use as a noninvasive aid in the examination and diagnosis of eye conditions and in the fitting of contact lenses for patients requiring ophthalmic evaluation.
Regulatory Classification
Identification
An AC-powered slitlamp biomicroscope is an AC-powered device that is a microscope intended for use in eye examination that projects into a patient's eye through a control diaphragm a thin, intense beam of light.
Special Controls
*Classification.* Class II (special controls). The device, when it is intended only for the visual examination of the anterior segment of the eye, is classified as Group 1 per FDA-recognized consensus standard ANSI Z80.36, does not provide any quantitative output, and is not intended for screening or automated diagnostic indications, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 886.9.
Predicate Devices
- Haag-Streit slitlamp 900® BQ
- Topcon slitlamp model SL-2ED
Related Devices
- K060869 — RS-1000 ZOOM SLITLAMP WITH OPTION · Rightmedical Products, LLC · May 11, 2006
- K982057 — BC 900 SLIT LAMP · Haag-Streit AG · Aug 14, 1998
- K163564 — SLIT LAMP SL-2000 · Nidek Co., Ltd. · May 19, 2017
- K110129 — RIGHTON ZOOM SLIT LAMP MICROSCOPE WITH PHOTO OPTION · Rightmedical Products, LLC · Aug 30, 2011
- K151394 — Keeler Slit Lamp · Keeler Limited · Sep 10, 2015