← Product Code [EBF](/productcode/EBF) · K962442

# HYTAC APLITIP/HYTAC OSB (K962442)

_Espe GmbH & Co. Kg. · EBF · Sep 11, 1996 · Dental · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K962442

## Device Facts

- **Applicant:** Espe GmbH & Co. Kg.
- **Product Code:** [EBF](/productcode/EBF.md)
- **Decision Date:** Sep 11, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 872.3690
- **Device Class:** Class 2
- **Review Panel:** Dental
- **Attributes:** Therapeutic, Pediatric

## Indications for Use

Hytac® Aplitip® is a compomer filling material indicated for the following uses: (1) fillings in deciduous teeth; (2) fillings in Class V cavities; (3) eroded and abraded cervical areas; (4) fillings in Class III cavities; and (5) temporary fillings in Class I and II cavities. Hytac® OSB is a light cured bonding agent for use with compomer filling materials.

## Device Story

Hytac® Aplitip® (compomer filling material) and Hytac® OSB (light-cured bonding agent) used by dentists for restorative dental procedures. Aplitip® applied to tooth cavities; OSB used as adhesive interface. Materials provide structural filling and bonding for specific cavity classes and deciduous teeth. Benefit: restorative dental care. Clinical decision-making: dentist selects material based on cavity classification and tooth type.

## Clinical Evidence

Bench testing only. Biocompatibility studies performed on final products including cytotoxicity, Ames test, skin/eye irritation, acute oral toxicity, and sensitization. Results showed no adverse toxicity or sensitization.

## Technological Characteristics

Compomer filling material and light-cured bonding agent. Materials meet relevant DIN and ISO standards for dental composite materials. Contains water-soluble fluoride.

## Regulatory Identification

Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl methacrylate (Bis-GMA) intended to restore carious lesions or structural defects in teeth.

## Predicate Devices

- Pertac®-Hybrid® ([K900510](/device/K900510.md))
- Pertac® Universal Bond ([K904289](/device/K904289.md))
- Compoglass® ([K951836](/device/K951836.md))
- Compoglass® SCA ([K951836](/device/K951836.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K962442
SEP 11 1996

## II. 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS

ESPE is submitting a 510(k) premarket notification for modifications to its 510(k) submissions for tooth shade resin material, tradenamed Pertac®-Hybrid® (K900510), and the corresponding bonding agent, tradenamed Pertac® Universal Bond (K904289). The modified materials, referred to by the tradenames Hytac® Aplitip® and Hytac® OSB, respectively, are intended as compomer filling material and corresponding bonding agent. Hytac® Aplitip® is a compomer filling material indicated for the following uses: (1) fillings in deciduous teeth; (2) fillings in Class V cavities; (3) eroded and abraded cervical areas; (4) fillings in Class III cavities; and (5) temporary fillings in Class I and II cavities. Hytac® OSB is a light cured bonding agent for use with compomer filling materials.

With respect to Hytac® Aplitip®, ESPE is claiming substantial equivalence to its previously cleared Pertac®-Hybrid® product and Ivoclar's Compoglass® (K951836). These products have similar intended uses and, in the case of Compoglass®, the same principal ingredient composition. To support substantial equivalence to predicate products, the physical and technical

WAHA/A36360.1

{1}

characteristics, as well as the water soluble fluoride content, of Hytac® Aplitip® have been compared to those of Pertac®-Hybrid® and Ivoclar's Compoglass®. In addition, certain tests have been undertaken on the final Hytac® product, including cytotoxicity, Ames, skin irritation, eye irritation, acute oral toxicity and sensitization. Results of these studies indicate that the final product shows no adverse toxicity results.

With respect to Hytac® OSB, ESPE is claiming substantial equivalence to its previously cleared Pertac® Universal Bond and to Ivoclar's Compoglass® SCA (K951836). All products have the same intended use and all but one of the same components. To support substantial equivalence to predicate products, the physical and technical characteristics of Hytac® OSB have been compared to those of Pertac® Universal Bond and Ivoclar's Compoglass® SCA. In addition, the sensitization test has been performed on the final Hytac® OSB product to confirm safe use of the product, and test results show no sensitization.

Hytac® Aplitip® and Hytac® OSB meet the requirements of relevant DIN and ISO standards for dental composite material.

WADIA/A38368.1

{2}

ESPE's 510(k) has been submitted on June 17, 1996, by Dr. Barbara Wagner at Am Griesberg 2, D-82229 Seefeld, Germany (011-49-8152-700395).

WADIA/A38360.1

---

**Source:** [https://fda.innolitics.com/device/K962442](https://fda.innolitics.com/device/K962442)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
