DEROYAL INDUSTRIES, INC. ELECTROSURGICAL CAUTERY PENCIL
Device Facts
| Record ID | K961647 |
|---|---|
| Device Name | DEROYAL INDUSTRIES, INC. ELECTROSURGICAL CAUTERY PENCIL |
| Applicant | Deroyal Industries, Inc. |
| Product Code | GEI · General, Plastic Surgery |
| Decision Date | Oct 8, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4400 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The DeRoyal Cautery Pencil is indicated for use whenever an electrosurgical procedure requires the removal of tissue or the control of bleeding by either cutting or coagulation.
Device Story
Electrosurgical cautery pencil; used in surgical procedures for tissue removal and hemostasis. Device delivers high-frequency electrical current to surgical site. Operated by surgeons/clinicians in clinical settings. Tip design facilitates cutting and coagulation. Titanium Nitride coating provides anti-stick properties. Device connects to standard electrosurgical generators.
Clinical Evidence
Bench testing only; no clinical data provided.
Technological Characteristics
Materials: Stainless steel tip, PVC cable insulation. Coating: Titanium Nitride (anti-stick). Dimensions: 6.0" pencil body, 10' cable. Energy source: High-frequency electrical current from external electrosurgical generator. Principle: Electrosurgical cutting and coagulation.
Indications for Use
Indicated for patients undergoing electrosurgical procedures requiring tissue removal or hemostasis via cutting or coagulation.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
Predicate Devices
- DeBusk Technology Corporation (no 510(k) number provided)
Related Devices
- K982743 — DISPOSABLE HAND SWITCHING PENCIL, PUSH BUTTON WITH AND WITHOUT HOLSTER, MODEL #'S SB 313 PB, SB 313 PBH · New Deantronics Taiwan , Ltd. · Sep 14, 1998
- K190643 — Medline Electrocautery Pencil · Medline Industries, Inc. · May 6, 2019
- K213786 — CiRX Single use electrosurgical pencil with non-coated and coated electrode · Ningbo Shun YE Medical Company, Ltd. · Jun 27, 2022
- K231405 — Sterile Single Use Electrosurgical Pencil with Non-Coated Electrode, Sterile Single Use Electrosurgical Pencil with Non-Stick Electrode · Jiangsu Rong FU Kang Medical Instruments Co., Ltd. · Jan 18, 2024
- K132199 — DEROYAL ELECTROSURGICAL PENCIL, ROCKER STYLE WITHOUT HOLSTER, DEROYAL ELECTROSURGICAL PENCIL, BUTTON STYLE WITHOUT HOLST · Deroyal Industries, Inc. · Oct 3, 2013