FILM SCANNER 300

K960839 · Cannon U.S.A., Inc. · LMA · Dec 18, 1996 · Radiology

Device Facts

Record IDK960839
Device NameFILM SCANNER 300
ApplicantCannon U.S.A., Inc.
Product CodeLMA · Radiology
Decision DateDec 18, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.2030
Device ClassClass 2

Intended Use

Both devices are designed to digitize medical images from x-ray film.

Device Story

Desktop x-ray film digitizing system; utilizes CCD linear sensor; features automatic film feeder with 100-sheet capacity; high-speed scanning; supports DICOM and FTP protocols over TCP/IP; operated by clinical staff; converts analog film images to digital format for display and diagnostic review; facilitates digital storage and transmission of medical images.

Clinical Evidence

No clinical data; bench testing via software evaluation performed to demonstrate substantial equivalence.

Technological Characteristics

Desktop form factor; CCD linear sensor; automatic film feeder; connectivity via TCP/IP (DICOM, FTP protocols).

Indications for Use

Indicated for digitizing medical images from x-ray film for clinical use.

Regulatory Classification

Identification

A medical image digitizer is a device intended to convert an analog medical image into a digital format. Examples include systems employing video frame grabbers, and scanners which use lasers or charge-coupled devices.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std.). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} K960839 DEC 18 1996 # 510(k) Summary (modified) Prepared: March 29, 1996 ## Submitter: Company Name: Canon USA, Inc. Company Address: One Canon Plaza Lake Success, NY 11042 Contact Person: Glenn Impal, Manager Phone Number: (516) 328-5605 Fax Number: (516) 328-5169 ## Device: Reason For 510(k): New Model Manufacturer: Canon Inc. Trade Name: Canon Model Name: Film Scanner 300 Classification Name: Image Digitizer FDA 510(k) #: K960839 ## Substantial Equivalent Device: Manufacturer: Vidar Trade Name: Vidar Model Name: VXR-12 Classification Name: Image Digitizer FDA 510(k) #: NOT AVAILABLE ## Description Of Device: The Canon Film Scanner is a desktop size x-ray film digitizing system with CCD linear sensor. Features high throughput due to high speed scan and automatic film feeder with 100 sheet capacity. DICOM and FTP protocol on TCP/IP are supported. ## Intended Use: Both devices are designed to digitize medical images from x-ray film. ## Technical Characteristics: Please refer to the attached COMPARISON CHART. ## Non-clinical Tests: Software evaluation is being performed to show substantial equivalence. ## Clinical Tests: N/A ## Conclusions: Please wait for the completed software evaluation report to be submitted under separate cover.