HEARING AID - AIR CONDUCTION
Device Facts
| Record ID | K960684 |
|---|---|
| Device Name | HEARING AID - AIR CONDUCTION |
| Applicant | Resound Corp. |
| Product Code | ESD · Ear, Nose, Throat |
| Decision Date | Apr 10, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 874.3300 |
| Device Class | Class 1 |
| Attributes | Therapeutic |
Intended Use
This air-conduction hearing instrument is intended to amplify sound pressure waves and transmit the signal to the external ear through the medium of air to compensate for hearing losses from mild to moderately-severe.
Device Story
Air-conduction hearing instrument; amplifies sound pressure waves; transmits signal to external ear. Powered by type 13 battery. Used by hearing aid dispensers to fit patients. Features digital programming of fitting parameters; retains program settings during battery changes. Seven factory-preset programs available for selection; dispenser cannot modify presets; modifications require factory intervention. Benefits patient by compensating for hearing loss.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Air-conduction hearing instrument; powered by type 13 battery. Digital programming of fitting parameters; non-volatile memory for program retention. Seven factory-preset programs. Materials and assembly techniques standard to hearing aid industry.
Indications for Use
Indicated for individuals with mild to moderately-severe hearing loss requiring air-conduction sound amplification.
Regulatory Classification
Identification
An air-conduction hearing aid is a wearable sound-amplifying device intended to compensate for impaired hearing that conducts sound to the ear through the air. An air-conduction hearing aid is subject to the requirements in § 800.30 or § 801.422 of this chapter, as applicable. The air-conduction hearing aid generic type excludes the group hearing aid or group auditory trainer, master hearing aid, and the tinnitus masker, regulated under §§ 874.3320, 874.3330, and 874.3400, respectively.
Predicate Devices
- ReSound® Personal Hearing System ED3-E (K950319)
Related Devices
- K964557 — RESOUND BT4 PERSONAL HEARING SYSTEM W/REMOTE CONTROL OPTION · Resound Corp. · Nov 27, 1996
- K974257 — RESOUND DIGITAL 2000-BT W/DIGITAL 2000-DF (DIGITAL PROGRAMMER) · Resound Corp. · Dec 12, 1997
- K960680 — RESOUND PERSONAL HEARING SYSTEMS EDR ENCORE SERIES MODELS EDR-E, EDR-ES, EDR-EV, & EDR-P1 · Resound Corp. · Apr 10, 1996
- K971031 — AUDALLION III HEARING SYSTEM · Gn Danavox, Inc. · Jun 17, 1997
- K971605 — RESOUND ED4 PERSONAL HEARING SYSTEM W/REMOTE CONTROL OPTION · Resound Corp. · Jul 3, 1997