← Product Code [GEI](/productcode/GEI) · K960476

# ETHICON BIPOLAR SCISSORS AND ACCESSORY CABLE (K960476)

_ETHICON, Inc. · GEI · Apr 5, 1996 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K960476

## Device Facts

- **Applicant:** ETHICON, Inc.
- **Product Code:** [GEI](/productcode/GEI.md)
- **Decision Date:** Apr 5, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4400
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

The intended use of the ETHICON Bipolar Scissor is to cut and coagulate soft tissue in open surgical procedures.

## Device Story

ETHICON Bipolar Scissors; reusable surgical instrument; connects to electrosurgical generator via ETHICON Bipolar Cable; facilitates dissection, transection, and bipolar coagulation of soft tissue; used in open surgical procedures by surgeons; provides mechanical cutting and electrical coagulation; benefits include combined cutting/coagulation functionality in single device.

## Clinical Evidence

Bench testing only. Preclinical laboratory and benchtop evaluations performed in compliance with ANSI/AAMI HF-18. No clinical data provided.

## Technological Characteristics

Reusable bipolar electrosurgical scissors; connects to electrosurgical generator via accessory cable; designed for open surgery; complies with ANSI/AAMI HF-18 standard.

## Regulatory Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

## Predicate Devices

- EVERSHEARS II Bipolar Laparoscopic Scissors

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K960476

# SECTION 7

## SUMMARY OF SAFETY AND EFFECTIVENESS

### 510(k) Summary of Safety and Effectiveness

Information supporting claims of substantial equivalence, as defined under the Federal Food, Drug and Cosmetic Act, respecting safety and effectiveness is summarized below. For the convenience of the Reviewer, this summary is formatted in accordance with the Agency's final rule "...510(k) Summaries and 510(k) Statements..." (21 CFR 807) and can be used to provide a substantial equivalence summary to anyone requesting it from the Agency.

**NEW DEVICE NAME**: ETHICON Bipolar Scissors and Accessory Cable

**PREDICATE DEVICE NAME**: EVERSHEARS II Bipolar Laparoscopic Scissors

### 510(k) SUMMARY

### Device Description

The ETHICON Bipolar Scissors are available in various standard sizes and shapes similar to conventional surgical scissors. These scissors can be connected to the bipolar output mode on electrosurgical generators to facilitate dissection, transection, and bipolar coagulation.

The ETHICON Bipolar Scissors are designed for use with the ETHICON Bipolar Cable (Accessory). The ETHICON Bipolar Cable is used to connect the ETHICON Bipolar Scissors to the generator (ESU).

### Intended Use

The intended use of the ETHICON Bipolar Scissor is to cut and coagulate soft tissue in open surgical procedures.

Continued on next page

ETHICON Bipolar Scissors and Accessory Cable
ETHICON, Inc.

{1}

# SUMMARY OF SAFETY AND EFFECTIVENESS, Continued

|  Indications Statement | The ETHICON Bipolar Scissors are non-sterile, reusable devices intended to facilitate cutting and bipolar coagulation of soft tissue in open surgical procedures.  |
| --- | --- |
|  Technological Characteristics | The new device is technologically the same as the predicate except that the device is not designed for endoscopic procedures. This difference does not raise any new questions of safety and effectiveness.  |
|  Performance Data | Preclinical laboratory and benchtop evaluations (complies with ANSI/AAMI HF-18) were performed to ensure that the device functions as intended. Clinical data was deemed unnecessary to support the Premarket Notification. Sufficient data has been gathered from pre-clinical and benchtop testing to assess the safety and effectiveness characteristics of the new device.  |
|  Conclusions | Based on the 510(k) summaries and 510(k) statements (21 CFR 807) and the information provided herein, we conclude that the new device is substantially equivalent to the Predicate Device under the Federal Food, Drug and Cosmetic Act.  |
|  Contact | John D. Paulson, Ph.D
Director, Regulatory Affairs
ETHICON, Inc.
Rt. #22 West
Somerville, NJ 08876-0151  |
|  Date | January 31, 1996  |

ETHICON Bipolar Scissors and Accessory Cable
ETHICON, Inc.

---

**Source:** [https://fda.innolitics.com/device/K960476](https://fda.innolitics.com/device/K960476)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
