PLANCON MIRCOLAMELLAR KERATOME

K960395 · Plancon Instruments · HNO · Apr 26, 1996 · Ophthalmic

Device Facts

Record IDK960395
Device NamePLANCON MIRCOLAMELLAR KERATOME
ApplicantPlancon Instruments
Product CodeHNO · Ophthalmic
Decision DateApr 26, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 886.4370
Device ClassClass 1
AttributesTherapeutic

Indications for Use

To perform micro lamellar keratoplasty for the correction of myopia or hyperopia

Device Story

Plancon Instruments micro lamellar keratoplasty system; used for refractive surgery (myopia/hyperopia correction). System components: gas-powered turbine motor (0-20,000 RPM), adjustable keratome head, stainless steel keratome blade, pneumatic fixation rings, applanation lenses, and vacuum power unit. Operated by ophthalmologists in clinical/surgical settings. Device creates corneal lamellar cuts; surgeon uses applanation lenses and fixation rings to stabilize eye; turbine motor drives keratome blade to perform resection. Output is precise corneal tissue resection; facilitates refractive correction. Benefits include surgical precision in lamellar keratoplasty procedures.

Clinical Evidence

Bench testing only. No clinical data provided.

Technological Characteristics

Materials: stainless steel, titanium, aluminum. Energy source: gas-powered turbine motor (0-20,000 RPM). Components: vacuum pump, pneumatic fixation rings, applanation lenses with engraved reticles. Mechanical operation; no gear system. No software or electronic control systems described.

Indications for Use

Indicated for patients requiring micro lamellar keratoplasty for the correction of myopia or hyperopia.

Regulatory Classification

Identification

A keratome is an AC-powered or battery-powered device intended to shave tissue from sections of the cornea for a lamellar (partial thickness) transplant.

Predicate Devices

Submission Summary (Full Text)

{0} 200 APR 26 1996 K960395 # SAFETY AND EFFECTIVENESS SUMMARY | Designation / Feature | Submitted device PLANCON INSTRUMENTS | Predicated device ① | Predicated device ② | | --- | --- | --- | --- | | Intended use | To perform micro lamellar keratoplasty for the correction of myopia or hyperopia | To perform micro lamellar keratoplasty for the correction of myopia or hyperopia | To perform micro lamellar keratoplasty for the correction of myopia or hyperopia | | System composition | Power unit Turbine motor Adjustable keratome head Keratome blade Pneumatic fixation rings Applanation lenses Plate checking gauge | Power unit Turbine motor Adjustable keratome head Keratome blade Pneumatic fixation rings Applanation lenses Plate checking gauge | Power unit Turbine motor Adjustable keratome head Keratome blade Pneumatic fixation rings Applanation lenses Plate checking gauge | | Power unit | Vacuum pump Battery Vacuum release valve Knob to regulate gas pressure Gas & vacuum pressure gauges Vacuum & turbine quick connectors Battery charger unit | Vacuum pump Battery Vacuum release valve Knob to regulate gas pressure Gas & vacuum pressure gauges Vacuum & turbine quick connectors Battery charger unit | Vacuum pump Battery Vacuum release valve Knob to regulate gas pressure Gas & vacuum pressure gauges Vacuum & turbine quick connectors Battery charger unit | {1} K960395 Page 2/2 # SAFETY AND EFFECTIVENESS SUMMARY | | PLANCON INSTRUMENTS | PREDICATED DEVICE 1 | PREDICATED DEVICE 2 | | --- | --- | --- | --- | | Turbine motor | Gas powered Adjustable speed 0 to 20 000 RPM (recommended 14 000 RPM) Material: stainless steel, titanium, and aluminium. No gear system | Gas powered Adjustable speed Material: stainless steel No gear system | Gas powered Adjustable speed from 10 to 24 000 RPM Pre-set speed 14 000 RPM Material: stainless steel and brass No gear system | | Keratome | Material: stainless steel Adjustable Safety: maximum cut depth, and checking gauge | Material: stainless steel Adjustable Permanent adjustable head with adjustment kno Safety: - maximum cut depth and checking gauge | Material: stainless steel Adjustable Safety: - maximum cut depth and checking gauge | | Pneumatic fixation rings | Material: stainless steel Double dovetails | Material: stainless steel Double dovetails | Material: stainless steel Double dovetails | | Applanation lenses | Material: clear plastic + stainless handle Engraved inner reticle diameter | Material: c ear plastic + stainless handle Engraved inner reticle diameter | Material: clear plastic + stainless handle Engraved inner reticle diameter |
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.