VOLMED OPERATION DRAPE
Device Facts
| Record ID | K955872 |
|---|---|
| Device Name | VOLMED OPERATION DRAPE |
| Applicant | Medal Intl. Sales Co., LLC |
| Product Code | KKX · General, Plastic Surgery |
| Decision Date | Mar 12, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4370 |
| Device Class | Class 2 |
Intended Use
As a protective patient covering during surgical procedures, such as to isolate a site of surgical incision from microbial and other contamination.
Device Story
Volmed Operation Drape; sterile surgical incise drape; transparent polyurethane film coated with acrylic medical-grade adhesive; supported by silicon-coated polyethylene release paper; polyethylene protective film on outer surface. Used in surgical settings to isolate incision sites from contamination. Applied by surgical staff to patient skin prior to incision. Acts as physical bacterial barrier. Benefits patient by reducing risk of surgical site contamination.
Clinical Evidence
Bench testing only. Biocompatibility established via in vitro cytotoxicity, guinea pig subcutaneous implantation, and rabbit dermal irritation tests. Human repeat insult patch test confirmed no irritation or allergic contact dermatitis. Microbial permeability study using S. aureus demonstrated effective bacterial barrier performance.
Technological Characteristics
Transparent polyurethane film; acrylic medical-grade adhesive; silicon-coated polyethylene release paper; polyethylene protective film. Gamma irradiation sterilization. Sizes: 10x10cm to 30x60cm. Class II device (79KKX).
Indications for Use
Indicated for use as a protective patient covering during surgical procedures to isolate the surgical incision site from microbial and other contamination.
Regulatory Classification
Identification
A surgical drape and drape accessories is a device made of natural or synthetic materials intended to be used as a protective patient covering, such as to isolate a site of surgical incision from microbial and other contamination. The device includes a plastic wound protector that may adhere to the skin around a surgical incision or be placed in a wound to cover its exposed edges, and a latex drape with a self-retaining finger cot that is intended to allow repeated insertion of the surgeon's finger into the rectum during performance of a transurethral prostatectomy.
Special Controls
*Classification.* Class II (special controls). The device, when it is an ear, nose, and throat surgical drape, a latex sheet drape with self-retaining finger cot, a disposable urological drape, a Kelly pad, an ophthalmic patient drape, an ophthalmic microscope drape, an internal drape retention ring (wound protector), or a surgical drape that does not include an antimicrobial agent, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 878.9.
Predicate Devices
- Steri-Drape® Surgical Incise Drapes (pre-1976)
Related Devices
- K101688 — EMM SURGICAL DRAPE-SPUNLACE W/PE SIDES, MODEL 13-004 · Exact Medical Manufacturing, Inc. · Sep 20, 2010
- K133080 — Plus Surgical Drapes (EO Sterilized), PMDB-XXX · Foshan Nanhai Plus Medical Co, Ltd. · Jun 24, 2015
- K141324 — HONGYU DISPOSABLE SURGICAL DRAPES · Weihai Hongyu Nonwoven Fabric Products Co., Ltd. · Apr 14, 2015
- K082297 — BUSSE SURGICAL DRAPE · Busse Hospital Disposables, Inc. · Dec 9, 2008
- K062480 — JOYKEY SURGICAL DRAPES (STERILE) · Joykey Industryial , Ltd. · Mar 5, 2007