DIAGNOSTIC ULTRASONIC TRANSDUCER

K941593 · Toshiba America Medical Systems, In.C · IYO · May 17, 1996 · Radiology

Device Facts

Record IDK941593
Device NameDIAGNOSTIC ULTRASONIC TRANSDUCER
ApplicantToshiba America Medical Systems, In.C
Product CodeIYO · Radiology
Decision DateMay 17, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1560
Device ClassClass 2

Indications for Use

The PSH-25GT, when used with the SSH-140A diagnostic ultrasound system, utilizes high frequency sound waves, beyond the range of human hearing, to perform diagnostic examinations. These sound waves are a form of non-ionizing radiation which can be used to demonstrate anatomical structures. Ultrasonic waves are easily focussed for the examination of small quantities of material and short time span phenomena. Additionally, ultrasound is especially beneficial in the examination of soft tissues. Doppler imaging permits investigation of vascular flow via the use of non-ionizing energy, rather than requiring the employment of ionizing radiation. Use of non-ionizing doppler radiation makes the PSH-25GT/SSH-140A combination highly applicable for visualizing cephalic structures.

Device Story

PSH-25GT is a diagnostic ultrasonic transducer designed for use with the Toshiba SSH-140A ultrasound system. It emits high-frequency, non-ionizing sound waves to visualize cephalic structures and assess vascular flow via Doppler imaging. Operated by physicians in clinical settings, the system processes reflected ultrasonic signals to generate anatomical images. The device aids in soft tissue examination and vascular investigation without ionizing radiation. Safety is managed through ALARA principles, grounding, and adherence to thermal/mechanical standards. Clinicians use the resulting images to inform diagnostic decisions, benefiting patients by providing a non-invasive imaging alternative.

Clinical Evidence

Bench testing only. Compliance with CDRH guidance for diagnostic ultrasound, IEC-601-1 for thermal/mechanical safety, and ISO-9001 manufacturing standards. No clinical trial data presented.

Technological Characteristics

Diagnostic ultrasonic transducer for transcranial doppler. Complies with IEC-601-1 (thermal/mechanical safety) and ISO-9001. Operates with Toshiba SSH-140A system. Employs non-ionizing ultrasonic energy. Includes software safety features to limit acoustic intensities per pre-enactment guidelines. Cleaning/disinfection protocols provided in manual.

Indications for Use

Indicated for transcranial doppler applications to visualize cephalic structures and investigate vascular flow in patients requiring diagnostic ultrasound examinations. Restricted to use by or on the order of a physician.

Regulatory Classification

Identification

An ultrasonic pulsed echo imaging system is a device intended to project a pulsed sound beam into body tissue to determine the depth or location of the tissue interfaces and to measure the duration of an acoustic pulse from the transmitter to the tissue interface and back to the receiver. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

Special Controls

*Classification.* Class II (special controls). A biopsy needle guide kit intended for use with an ultrasonic pulsed echo imaging system only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

Predicate Devices

Submission Summary (Full Text)

{0} TOSHIBA TOSHIBA AMERICA MEDICAL SYSTEMS, INC. 2441 MICHELLE DRIVE, P.O. BOX 2068. TUSTIN, CA 92681-2068 PHONE (714) 30-5000 Appendix X # 510(k) Summary K941593 MAY 17 1996 Date: 31 March 1994 Submitter: Toshiba America Medical Systems, Inc. 2441 Michelle Drive P.O. Box 2068 Tustin, CA 92681-2068 Contact: Steven M. Kay (714) 730-5000 Classification Name: Diagnostic Ultrasonic Transducer Classification: Class II per 21 CFR 892.1570 Device Tier: 2, per the December 15, 1993 DRAERD Triage Pilot Program Common Name: Transcranial Doppler Transducer Proprietary Name: PSH-25GT Model Name: PSH-25GT Establishment Registration Number: 2020563 ## Compliance With Performance Standards: This device complies with the Performance Standards for Electronic Products, 21 CFR 1010, as administered by the Center for Devices and Radiological Health and with CDRH guidances "Revised 510(k) Diagnostic Ultrasound Guidance for 1993" and "510(k) Guide for Measuring and Reporting Acoustic Output of Diagnostic Ultrasound Medical Devices". It also complies with the Japanese (JIS) and European (IEC-601-1) voluntary standards and the ISO-9001 manufacturing standard. ## Substantial Equivalence Summary: The PSH-25GT is to be used with the Toshiba SSH-140A Track I Diagnostic Ultrasound system and claims substantial equivalency to the PSF-37FT, which was cleared for use with the SSH-140A Diagnostic Ultrasound System via K894632 and with the P3-2 Transcranial Doppler transducer distributed by Advanced Technology Labs (ATL). The PSH-25GT and PSF-37FT probes are manufactured by Toshiba Corporation of Japan and distributed by TAMS, have the same methods of manufacture, follow the same software verification and validation procedures and employ the same general technology. While the PSH-25GT and PSF-37FT mainly differ in their indications for use (transcranial doppler vs cardiac, respectively), the PSH-25GT and P3-2 probes are intended for transcranial doppler applications. {1} # Summary of Safety and Effectiveness The PSH-25GT, when used with the SSH-140A diagnostic ultrasound system, utilizes high frequency sound waves, beyond the range of human hearing, to perform diagnostic examinations. These sound waves are a form of non-ionizing radiation which can be used to demonstrate anatomical structures. Ultrasonic waves are easily focussed for the examination of small quantities of material and short time span phenomena. Additionally, ultrasound is especially beneficial in the examination of soft tissues. Doppler imaging permits investigation of vascular flow via the use of non-ionizing energy, rather than requiring the employment of ionizing radiation. Use of non-ionizing doppler radiation makes the PSH-25GT/SSH-140A combination highly applicable for visualizing cephalic structures. The application of ALARA (as low as reasonably achievable) principles minimize any potential harmful effects. At diagnostic levels, the benefits of using ultrasound for imaging procedures far outweigh its risks. # The PSH-140A 1. labelling clearly specifies "Caution: Federal law restricts this device to use by or on the order of a physician"; 2. is intended for a specific application which is familiar to medical practice and is substantially equivalent to devices legally entered into commercial distribution; 3. when used with the SSH-140A, employs software safety features to prevent acoustic intensities from exceeding Pre-enactment guidelines; 4. probe/ultrasound generator system electrical safety is assured through proper grounding and, where local codes require, is certified through electrical certification performed by a nationally recognized testing agent (NRTL); 5. the probe operation manual informs the user to practice the principles of ALARA; 6. thermal and mechanical safety aspects comply with the IEC-601-1 standard; 7. cleaning and disinfection protocols are detailed in the transducer operations manuals. Agents for cleaning and disinfection are readily available through common suppliers and labeling cautions the user to follow the agent's manufacturer's instructions. TOSHIBA AMERICA MEDICAL SYSTEMS, INC.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...