← Product Code [KOH](/productcode/KOH) · K840308

# CAT. 4-OBSTETRICS GYNECOLOGY DEV'S (K840308)

_Imm Enterprises , Ltd. · KOH · Mar 5, 1984 · Obstetrics/Gynecology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K840308

## Device Facts

- **Applicant:** Imm Enterprises , Ltd.
- **Product Code:** [KOH](/productcode/KOH.md)
- **Decision Date:** Mar 5, 1984
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 884.4520
- **Device Class:** Class 1
- **Review Panel:** Obstetrics/Gynecology

## Regulatory Identification

An obstetric-gynecologic general manual instrument is one of a group of devices used to perform simple obstetric and gynecologic manipulative functions. This generic type of device consists of the following:(1) An episiotomy scissors is a cutting instrument, with two opposed shearing blades, used for surgical incision of the vulvar orifice for obstetrical purposes. (2) A fiberoptic metal vaginal speculum is a metal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina. (3) A metal vaginal speculum is a metal instrument used to expose the interior of the vagina. (4) An umbilical scissors is a cutting instrument, with two opposed shearing blades, used to cut the umbilical cord. (5) A uterine clamp is an instrument used to hold the uterus by compression. (6) A uterine packer is an instrument used to introduce dressing into the uterus or vagina. (7) A vaginal applicator is an instrument used to insert medication into the vagina. (8) A vaginal retractor is an instrument used to maintain vaginal exposure by separating the edges of the vagina and holding back the tissue. (9) A gynecological fibroid hook is an instrument used to exert traction upon a fibroid. (10) A pelvimeter (external) is an instrument used to measure the external diameters of the pelvis.

---

**Source:** [https://fda.innolitics.com/device/K840308](https://fda.innolitics.com/device/K840308)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
