← Product Code [PNR](/productcode/PNR) · K260615

# 1 ml Enteral Feeding Syringe with ENFit Connector Low Dose (21EN-0103000004); 1 ml Enteral Feeding Syringe with ENFit Connector Low Dose - Amber (21EN-0103000005); 5 ml Enteral Feeding Syringe with ENFit Connector  (21EN-0503000004); 5 ml Enteral Feeding Syringe with ENFit Connector - Amber (21EN-0503000005); 5 ml Enteral Feeding Syringe with ENFit Connector Low Dose  (21EN-0503000006); 5 ml 3 part ENFit Syringe Single Use - Low Dose - Amber (21EN-0503000007); 10/12 ml Enteral Feeding (K260615)

_Set Medikal Sanayi ve Ticaret A.S. · PNR · Nov 20, 2026 · Gastroenterology, Urology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K260615

## Device Facts

- **Applicant:** Set Medikal Sanayi ve Ticaret A.S.
- **Product Code:** [PNR](/productcode/PNR.md)
- **Decision Date:** Nov 20, 2026
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 876.5980
- **Device Class:** Class 2
- **Review Panel:** Gastroenterology, Urology

## Regulatory Identification

A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use).

## Special Controls

*Classification.* (1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.

---

**Source:** [https://fda.innolitics.com/device/K260615](https://fda.innolitics.com/device/K260615)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
