← Product Code [ETA](/productcode/ETA) · K260264

# Medi Astro Total and Partial Ossicular Prostheses (Type TORP, Type PORP, and Type PISTON) (K260264)

_Shanghai Medi Astro Technology Co., Ltd. · ETA · Oct 14, 2026 · Ear, Nose, Throat · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K260264

## Device Facts

- **Applicant:** Shanghai Medi Astro Technology Co., Ltd.
- **Product Code:** [ETA](/productcode/ETA.md)
- **Decision Date:** Oct 14, 2026
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 874.3495
- **Device Class:** Class 2
- **Review Panel:** Ear, Nose, Throat
- **Attributes:** Therapeutic, Pediatric

## Indications for Use

Medi Astro Total and Partial Ossicular Prostheses” are devices intended to be implanted for the functional reconstruction of segments of the ossicular chain. They are intended to facilitate the conduction of sound wave from the tympanic membrane to the inner ear. Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. Indications for use include: - (a) Chronic middle ear disease, - (b) Otosclerosis, - (c) Congenital fixation of the stapes, - (d) Secondary surgical intervention to correct for a significant and persistent conductive hearing loss from prior otologic surgery, and - (e) Surgically correctible injury to the middle ear from trauma.

## Device Story

Artificial implants for ossiculoplasty; bridge gaps in damaged/missing ossicular chain (malleus, incus, stapes). Conducts sound from tympanic membrane to inner ear. Used in middle ear surgery; implanted by ENT surgeons. Available as TORP, PORP, and PISTON types; various lengths/diameters for anatomical fit. Manufactured from unalloyed titanium. Delivered sterile; radiation-sterilized. Improves hearing outcomes for patients with conductive hearing loss.

## Clinical Evidence

No clinical study was performed. Evidence is based on bench testing, including appearance, dimension, mechanical properties, MRI compatibility (displacement, torque, artifact), and sound transmission verification.

## Technological Characteristics

Materials: Unalloyed titanium (ASTM F67 Grade 4). Design: TORP, PORP, and PISTON configurations. Dimensions: Lengths 1.5-10 mm; diameters 0.3-0.6 mm. Sterilization: Radiation (ISO 11137-2). Packaging: ISO 11607. MRI: Conditional (1.5T, 3T, 7T).

## Regulatory Identification

A total ossicular replacement prosthesis is a device intended to be implanted for the total functional reconstruction of the ossicular chain and facilitates the conduction of sound waves from the tympanic membrance to the inner ear. The device is made of materials such as polytetrafluoroethylene, polytetrafluoroethylene with vitreous carbon fibers composite, porous polyethylene, or from a combination of these materials.

## Predicate Devices

- Grace Medical Adjustable and Fixed Length Partial & Total Ossicular Replacement Prostheses, Types FLTO and FLPO ([K061853](/device/K061853.md))
- K Piston ([K002221](/device/K002221.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{1}

FDA U.S. FOOD & DRUG
ADMINISTRATION

October 14, 2026

Shanghai Medi Astro Technology Co., Ltd.
% Charles Shen
Vice President
Manton Business and Technology Services
Contact Address

Re: K260264

Trade/Device Name: Medi Astro Total and Partial Ossicular Prostheses (Type TORP, Type PORP, and Type PISTON)

Regulation Number: 21 CFR 874.3495

Regulation Name: Total Ossicular Replacement Prosthesis

Regulatory Class: Class II

Product Code: ETA, ETB

Dated: September 15, 2026

Received: September 15, 2026

Dear Charles Shen:

We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Before making any change significantly affecting the safety or effectiveness of the device, you must submit a new premarket notification in accordance with 21 CFR 807.81. Additional information about changes that

U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov

{2}

K260264 - Charles Shen

Page 2

may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).

Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13485 clause 8.3 (Nonconforming product), ISO 13485 clause 8.5.2 (Corrective action), and ISO 13485 clause 8.5.3 (Preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and ISO 13485 clause 7.5) and document changes and approvals in the Medical Device File (ISO 13485 clause 4.2.3).

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.

All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-

{3}

K260264 - Charles Shen

Page 3

assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

SHUCHEN PENG -S

Shu-Chen Peng, Ph.D.

Assistant Director

DHT1B: Division of Dental and ENT Devices

OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT, and Dental Devices

Office of Product Evaluation and Quality

Center for Devices and Radiological Health

Enclosure

{4}

DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration

# **Indications for Use**

Form Approved: OMB No. 0910-0120
Expiration Date: 07/31/2026
See PRA Statement below.

510(k) Number (if known)

K260264

Device Name

Medi Astro Total and Partial Ossicular Prostheses (Type TORP, Type PORP, and Type PISTON)

Indications for Use (Describe)

"Medi Astro Total and Partial Ossicular Prostheses" are devices intended to be implanted for the functional reconstruction of segments of the ossicular chain. They are intended to facilitate the conduction of sound wave from the tympanic membrane to the inner ear.

Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. Indications for use include:

- (a) Chronic middle ear disease,
- (b) Otosclerosis,
- (c) Congenital fixation of the stapes,
- (d) Secondary surgical intervention to correct for a significant and persistent conductive hearing loss from prior otologic surgery, and
- (e) Surgically correctible injury to the middle ear from trauma.

Type of Use (Select one or both, as applicable)

☑ Prescription Use (Part 21 CFR 801 Subpart D)

☐ Over-The-Counter Use (21 CFR 801 Subpart C)

**CONTINUE ON A SEPARATE PAGE IF NEEDED.**

This section applies only to requirements of the Paperwork Reduction Act of 1995.

**\*DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.\***

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

FORM FDA 3881 (8/23)

Page 1 of 1

PSC Publishing Services (301) 443-6740 EF

{5}

## 510(k) Summary: K260264

This summary of 510k safety and effectiveness information is being submitted in accordance with the requirements of 21CFR 807.92

### 1.0 Submitter & Foreign Manufacture Identification

Shanghai Medi Astro Technology Co., Ltd
Room 1001, Building 1, No. 98, Fulian 1st Road, Baoshan District, Shanghai, 201906,
China
Tel : 86-021-56788123
Submitter's FDA Registration Number: N/A

### 2.0 Contact Person

![img-0.jpeg](img-0.jpeg)

Charles Shen
Manton Business and Technology Services (Shanghai)
37 Winding Ridge, Oakland, NJ 07436
Tel: 608-217-9358
Email: cyshen@aol.com

### 3.0 Date of Summary: October 07, 2026

### 4.0 Device Name:

|  Proprietary Name: | Ossicular replacement prosthesis (total and partial)  |
| --- | --- |
|  Common Name: | Ossicular replacement prosthesis (total and partial)  |
|  Classification Name: | Replacement, Ossicular Prosthesis, Total; Prosthesis, Partial Ossicular replacement  |
|  Device Classification: | II  |
|  Regulation Number: | 21 CFR 874.3495, 21 CFR 874.3450  |
|  Product Code: | ETA, ETB  |
|  Panel: | Ear Nose & Throat  |

510(k) Summary

Page 1

{6}

## **5.0 Predicate Device Information:**

K061853, “Grace Medical Adjustable and Fixed Length Partial & Total Ossicular Replacement Prostheses, Types FLTO and FLPO”, manufactured by “Grace Medical, Inc.”

K002221, “K Piston”, manufactured by “HEINZ KURZ GMBH MEDIZINTECHNIK.”

## **6.0 Device Description:**

“Medi Astro Total and Partial Ossicular Prostheses” are artificial implants used in ossiculoplasty surgery to restore conductive hearing by bridging a gap in the damaged or missing ossicular chain (malleus, incus, stapes) of the middle ear. These prostheses aim to conduct sound from the tympanic membrane to the inner ear, improving hearing outcomes after conditions such as cholesteatoma or chronic otitis media.

“Medi Astro Total and Partial Ossicular Prostheses” are intended to be implanted only by qualified ENT surgeons with adequate skills to perform otological surgeries. Replacement of the ossicular chain is a standard surgical procedure, and no additional device specific training is mandatory or required for the safe and effective use.

The target patient populations for “Medi Astro Total and Partial Ossicular Prostheses” are those of all ages requiring reconstruction of the ossicular chain.

“Medi Astro Total and Partial Ossicular Prostheses” are manufactured from unalloyed titanium metal meeting ASTM F67 Grade 4 specifications.

“Medi Astro Total and Partial Ossicular Prostheses” are available in different designs, functional lengths, and/or piston diameters , to allow the surgeons more flexibility in terms of selecting the correct prosthesis according to individual patient’s anatomical needs and the surgeon’s surgical preference and proficiency.

“Medi Astro Total and Partial Ossicular Prostheses” are delivered in a sterile condition and can be used without any further preparations. The devices are sterilized with radiation and packaged in accordance with ISO 11607.

“Medi Astro Total and Partial Ossicular Prostheses” includes three different types: Medi Astro PORP, Medi Astro TORP, and Medi Astro PISTON.

510(k) Summary

Page 2

{7}

## 7.0 Indications for Use:

“Medi Astro Total and Partial Ossicular Prostheses” are devices intended to be implanted for the functional reconstruction of segments of the ossicular chain. They are intended to facilitate the conduction of sound wave from the tympanic membrane to the inner ear.

Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. Indications for use include:

- (a) Chronic middle ear disease,
- (b) Otosclerosis,
- (c) Congenital fixation of the stapes,
- (d) Secondary surgical intervention to correct for a significant and persistent conductive hearing loss from prior otologic surgery, and
- (e) Surgically correctible injury to the middle ear from trauma.

## 8.0 Technological Comparison with Predicate Device

The following table shows similarities and differences of use, design, and material between our device and the predicate devices.

**Table 1: Comparison of Intended Use, Design, Material, and Processing of the TORP Type with its Predicate Device**

|  Description | Subject Device (TORP Type) | Predicate Device (K061853) Fixed Length Total Ossicular (FLTO)  |
| --- | --- | --- |
|  Indication for Use | Medi Astro Total and Partial Ossicular Prostheses” are devices intended to be implanted for the functional reconstruction of segments of the ossicular chain. They are intended to facilitate the conduction of sound wave from the tympanic membrane to the inner ear. Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. | An ossicular replacement prosthesis is a device intended to be implanted for the functional reconstruction of segments of the ossicular chain and facilitates the conduction of sound wave from the tympanic membrane to the inner ear. Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present.  |

510(k) Summary

Page 3

{8}

|  Design |  |   |
| --- | --- | --- |
|  Materials | Titanium (ASTM F67) | Titanium, Silicone, Polyethylene, Hydroxylapatite, etc  |
|  Dimension (Length) | 3.0 to 7 mm | 0.5 to 9.0 mm  |
|  Diameter | 3.0 (Base) 0.4 (Shaft) | 3.0 (Base) 0.2 (Shaft)  |
|  Mass | 5.72-8.10 mg | No public information available  |
|  Head Shape | Circular | Circular, Semi-circular, Oval, Oblong, Notched  |
|  Single Use | Yes | Yes  |
|  Sterile | Yes | Yes  |
|  MRI | MRI Conditional (1.5T, 3T, 7T) | MRI Conditional (1.5T, 3T, 7T)  |

Additionally, sound transmission verification (see 10.0 below) confirmed similar performance between subject and predicate devices despite minor differences in dimension, shape, and materials.

The subject device, “Medi Astro Total and Partial Ossicular Prostheses, TORP Type”, is similar to the predicate device in terms of indications for use, design, material, and processing.

**Table 2: Comparison of Intended Use, Design, Material, and Processing of the PORP Type with its Predicate Device**

|  Description | Subject Device (PORP Type) | Predicate Device (K061853) Fixed Length Partial Ossicular (FLPO)  |
| --- | --- | --- |
|  Indication for Use | Medi Astro Total and Partial Ossicular Prostheses” are devices intended to be implanted for the functional reconstruction of segments of the ossicular chain. They are intended to facilitate the conduction of sound wave from the tympanic membrane to the inner ear. Ossicular replacement prostheses are | An ossicular replacement prosthesis is a device intended to be implanted for the functional reconstruction of segments of the ossicular chain and facilitates the conduction of sound wave from the tympanic membrane to the inner ear. Ossicular replacement prostheses are indicated for the functional restoration  |

510(k) Summary

Page 4

{9}

|   | indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. | of the ossicular chain when a conductive hearing loss is present.  |
| --- | --- | --- |
|  Design |  |   |
|  Materials | Titanium (ASTM F67) | Titanium, Silicone, Polyethylene, Hydroxylapatite, etc  |
|  Dimension (Length) | 1.5 to 4.5 mm | 0.5 to 9.0 mm  |
|  Diameter | 3.0 (Base) 0.3 (Shaft) | 3.0 (Base) 0.2 (Shaft)  |
|  Mass | 5.60-6.13 mg | No public information available  |
|  Head Shape | Circular | Circular, Semi-circular, Oval, Oblong, Notched  |
|  Single Use | Yes | Yes  |
|  Sterile | Yes | Yes  |
|  MRI | MRI Conditional (1.5T, 3T, 7T) | MRI Conditional (1.5T, 3T, 7T)  |

Additionally, sound transmission verification (see 10.0 below) confirmed similar performance between subject and predicate devices despite minor differences in dimension, shape, and materials.

The subject device, “Medi Astro Total and Partial Ossicular Prostheses, PORP Type”, is similar to the predicate device in terms of indications for use, design, material, and processing between our device and the predicate device.

Table 3: Comparison of Intended Use, Design, Material, and Processing of the Piston Type with its Predicate Device

|  Description | Subject Device (PISTON Type) | Predicate Device (K002221) (K Piston)  |
| --- | --- | --- |
|  Indication for Use | Medi Astro Total and Partial Ossicular Prostheses” are devices intended to be implanted for the functional reconstruction of segments of the ossicular chain. They are intended to facilitate the conduction of sound wave from the tympanic | The device is intended for the partial or total surgical replacement of the ossicular chain of the human middle ear. The objective is the restoration of the mechanical transfer of sound from the  |

510(k) Summary

Page 5

{10}

|   | membrane to the inner ear. Ossicular replacement prostheses are indicated for the functional restoration of the ossicular chain when a conductive hearing loss is present. | tympanic membrane to the oval window of the cochlear with the least impairment of hearing.  |
| --- | --- | --- |
|  Design |  |   |
|  Materials | Titanium (ASTM F67) | Titanium (ASTM F67)  |
|  Method of Attachment | Manually with crimping | Manually with crimping  |
|  Dimension (Length) | 3.5 to 10 mm | 3.5 to 10 mm  |
|  Diameter | 0.4 to 0.6 mm | 0.4 to 0.6 mm  |
|  Mass | 3.01-11.17 mg (diameter 0.6 mm) 1.87-6.50 mg (diameter 0.4 mm) | No public information available  |
|  Width with Loop Band | 0.25 mm | 0.3 mm  |
|  Single Use | Yes | Yes  |
|  Sterile | Yes | Yes  |
|  MRI | MRI Conditional (1.5T, 3T, 7T) | MRI Conditional (1.5T, 3T, 7T)  |

The intended use of the subject device and predicate device are the same, despite differences in the wording of the two indications for use statements.

Additionally, sound transmission verification (see 10.0 below) confirmed similar performance between subject and predicate devices despite minor differences in dimension and shape.

The subject device, “Medi Astro Total and Partial Ossicular Prostheses, Piston Type”, is similar to the predicate devices in terms of indications for use, design, material, and dimension between our device and the predicate device.

Therefore, the subject devices, “Medi Astro Total and Partial Ossicular Prostheses (TORP, PORP, and PISTON Types)” are similar to the predicate devices (“Grace

510(k) Summary

Page 6

{11}

Medical Adjustable and Fixed Length Partial & Total Ossicular Replacement Prostheses, Type FLTO”, “Grace Medical Adjustable and Fixed Length Partial & Total Ossiculareplacement Prostheses, Type FLPO”, and “K Piston”) in terms of indications for use, design, material, and performance.

## 9.0 Biocompatibility Evaluation

Per FDA's guidance document entitled “Use of International Standard ISO 10993-1, ‘Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process,’”, as well as ISO 10993-1: 2018, the following biocompatibility endpoints were evaluated:

Cytotoxicity (**ISO 10993-5**)

Sensitization (**ISO 10993-10**)

Irritation (**ISO 10993-23**)

- Acute Systemic Toxicity (**ISO 10993-18 and ISO 10993-17**)

- Subacute/Subchronic Systematic Toxicity (**ISO 10993-18 and ISO 10993-17**)

- Chronic Systematic Toxicity (**ISO 10993-18 and ISO 10993-17**)

Material-Mediated Pyrogenicity (**ISO 10993-11**)

Implantation

Genotoxicity (**ISO 10993-18 and ISO 10993-17**)

Carcinogenicity (**ISO 10993-18 and ISO 10993-17**)

## 10.0 Summary of Non-Clinical Testing:

The following non-clinical tests were performed:

Appearance

Dimension

Mechanical Properties

MR Induced Displacement and Torque

MR Induced Artifact

Sound Transmission Verification

The physical and performance of the subject device meets the requirements of its pre-defined acceptance criteria and intended uses. All prostheses are sterilized and sold directly to users after sterilization by radiation using conditions validated following ISO 11137-2: 2012. The product is safe and effective for its intended use.

## 11.0 Summary of Clinical Study:

Clinical Study was not performed for this device.

## 12.0 Substantial Equivalence Conclusion

It has been shown in this 510(k) submission that “Medi Astro Total and Partial Ossicular Prostheses” and its predicate devices have similar indications for use, similar composition, and biocompatibility, and similar performance.

510(k) Summary

Page 7

{12}

The difference between the “Medi Astro Total and Partial Ossicular Prostheses” and their predicate devices do not raise any question regarding its equivalence.

In accordance with the Federal Food, Drug and Cosmetic Act, 21 CFR Part 807 and based on the information provided in this premarket notification, the subject devices are respectively substantially equivalent to their predicate devices.

510(k) Summary

Page 8

---

**Source:** [https://fda.innolitics.com/device/K260264](https://fda.innolitics.com/device/K260264)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
