K252628 · Apr 27, 2026
CASSIE
Wesper, Inc.
National Sleep Research Resource (NSRR) PSG datasets
Retrospective validation study using existing clinical PSG recordings to assess the accuracy of the Cassie PPG-based sleep testing system against the reference standard.
Retrospective; PSG; Sleep study; Validation
Clinical Evidence
Study Design
Population
Comparator
Key Endpoints
Multi-site retrospective validation study; Retrospective validation study
Diverse patient populations from the National Sleep Research Resource; Sample Size: 474 independent test subjects; Number of Sites: Multi-site
Polysomnography (PSG)
Apnea-Hypopnea Index (AHI), Total Sleep Time (TST), Sleep Staging, Wake After Sleep Onset (WASO), Oxygen Desaturation Index (ODI), Sleep Fragmentation Index (SFI)
AI Performance
Output
Algorithm
Acceptance
Observed
Dev DS
Dev Readers
Test DS
Test Readers
Apnea-Hypopnea Index (AHI)
Machine learning analysis of cardiopulmonary physiological markers
—
Pearson correlation 0.96 (95% CI: 0.95-0.96); Bland-Altman limits of agreement -9.92 to 13.02 events/hr
—
—
Multi-site retrospective validation study using 474 independent test subjects from the National Sleep Research Resource.
>1 (certified technologists)
Total Sleep Time (TST)
Machine learning analysis of cardiopulmonary physiological markers
—
Pearson correlation 0.86 (95% CI: 0.84-0.89); Bland-Altman limits of agreement -79.26 to 92.48 min
—
—
Multi-site retrospective validation study using 474 independent test subjects from the National Sleep Research Resource.
>1 (certified technologists)
Sleep Staging
Machine learning analysis of cardiopulmonary physiological markers
—
Sensitivity/Specificity: Wake (75.2%/93.9%), Light Non-REM (66.4%/79.9%), Deep Non-REM (73.6%/86.5%), REM (73.9%/95.9%)
—
—
Multi-site retrospective validation study using 474 independent test subjects from the National Sleep Research Resource.
>1 (certified technologists)
Indications for Use
Cassie is a Software as a Medical Device (SaMD) that automatically analyzes, displays, and summarizes Photoplethysmogram (PPG) data, typically collected during sleep using compatible devices. Cassie is intended for use by and by order of a healthcare professional to aid in the evaluation of sleep disorders, where it may inform or drive clinical management for adults. The Wesper Apnea Hypopnea Index (wAHI) and other outputs presented when oximeter data is available are intended to aid healthcare professionals in diagnosis and management of sleep disordered breathing. The Cassie output is not intended to be interpreted or clinical action taken without consultation of a qualified healthcare professional.
Device Story
Cassie is an AI-based SaMD that processes physiological data from sleeping patients to assist clinicians in diagnosing sleep disorders. Input consists of PPG waveforms and optional SpO2 data from standard EDF files collected via compatible pulse oximeters (e.g., Nonin 8000 series). The system operates as a cloud-based web application accessed via API. Machine learning models analyze cardiopulmonary markers to classify sleep stages (Wake, Light, Deep, REM) and detect respiratory events. Outputs include sleep architecture metrics (TST, WASO, sleep efficiency) and respiratory indices (wAHI, ODI). Clinicians review these outputs and raw physiological channels through a web interface to inform clinical management. The device is intended for use by or under the order of healthcare professionals; it does not replace professional clinical judgment.
Clinical Evidence
Multi-site retrospective validation study using 474 independent test subjects from the National Sleep Research Resource. Performance compared against gold-standard PSG scored by certified technologists. Primary endpoints: AHI correlation (r=0.96, 95% CI 0.95-0.96) and TST correlation (r=0.86, 95% CI 0.84-0.89). OSA severity classification (AHI ≥5) showed 97.3% sensitivity and 86.1% specificity (3% desaturation). Results confirm performance is consistent with predicate device ranges.
Technological Characteristics
Cloud-based SaMD utilizing machine learning models to analyze cardiopulmonary physiological markers. Inputs: PPG and optional SpO2 (EDF format). Outputs: Sleep architecture, respiratory events, and scalar metrics (AHI, TST, etc.). Operates on general-purpose computing platforms via API. Software developed per IEC 62304:2006. Cybersecurity controls implemented per FDA guidance.
Indications for Use
Indicated for adults to aid in the evaluation of sleep disorders and sleep-disordered breathing by analyzing PPG and optional oximetry data collected during sleep.
Regulatory Classification
Identification
A breathing (ventilatory) frequency monitor is a device intended to measure or monitor a patient's respiratory rate. The device may provide an audible or visible alarm when the respiratory rate, averaged over time, is outside operator settable alarm limits. This device does not include the apnea monitor classified in § 868.2377.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.