K251139 · Fresenius Kabi AG · KPE · Jan 9, 2026 · General Hospital
Device Facts
Record ID
K251139
Device Name
KabiHelp® Uno; KabiHelp® Advance plus
Applicant
Fresenius Kabi AG
Product Code
KPE · General Hospital
Decision Date
Jan 9, 2026
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5025
Device Class
Class 2
Indications for Use
The KabiHelp® Bag is an empty container to be filled with components of parenteral nutrition and parenteral nutrition related medication to be administered to the patients using an intravascular administration set. Parenteral nutrition and parenteral nutrition related medication transfer in and out of the container is done using aseptic technique.
Device Story
KabiHelp® Bag is an empty plastic container designed for parenteral nutrition and related medication storage and administration. It features three ports: a filling port for use with KabiHelp Transfer Sets, an injection port for additives, and an administration port for infusion. The device is used in aseptic environments to prepare solutions, which are then administered to patients via an intravascular administration set. After filling, the bag is secured with a non-reopening clamp. Available in monolayer or multilayer configurations, it is designed for use with the KabiHelp Pro Compounding System. The device facilitates the safe transfer and delivery of nutritional components, benefiting patients requiring intravenous nutrition by providing a sterile, compatible container system.
Clinical Evidence
No clinical study was conducted. Substantial equivalence is supported by non-clinical bench testing, including biocompatibility (ISO 10993-1, -5, -10, -23, -11, USP <151>, ASTM F756), plastic container performance (ISO 15747), particulate matter (USP <788>), package integrity (ISO 11607-1), and a human factors usability study.
Technological Characteristics
Empty plastic container; monolayer EVA or multilayer EVA/EVOH construction. Includes filling, injection, and administration ports. Sterilized via Ethylene Oxide (EO) to SAL 10^-6. Materials include EVA, PVC, ABS, PS, EVOH, and various dyes. Complies with ISO 15747 and ISO 10993-1. Non-reusable.
Indications for Use
Indicated for use as an empty container for the preparation and administration of parenteral nutrition and related medications to patients via an intravascular administration set.
Regulatory Classification
Identification
An I.V. container is a container made of plastic or glass used to hold a fluid mixture to be administered to a patient through an intravascular administration set.
{0}
FDA U.S. FOOD & DRUG ADMINISTRATION
January 9, 2026
Fresenius Kabi AG
% Rhoda Valera
Senior Director, Regulatory Affairs
Fresenius Kabi
Three Corporate Dr.
Lake Zurich, Illinois 60047
Re: K251139
Trade/Device Name: KabiHelp® Uno; KabiHelp® Advance plus
Regulation Number: 21 CFR 880.5025
Regulation Name: I.V. container
Regulatory Class: Class II
Product Code: KPE
Dated: December 10, 2025
Received: December 10, 2025
Dear Rhoda Valera:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device"
U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov
{1}
K251139 - Rhoda Valera
Page 2
(https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
{2}
K251139 - Rhoda Valera
Page 3
Sincerely,
DAVID WOLLOSCHECK -S
David Wolloscheck, Ph.D.
Assistant Director
DHT3C: Division of Drug Delivery and
General Hospital Devices, and
Human Factors
OHT3: Office of Gastrorenal, ObGyn,
General Hospital, and Urology Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health
Enclosure
{3}
FORM FDA 3881 (8/23)
Page 1 of 1
PSC Publishing Services (301) 443-6740
EF
| DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. |
| --- | --- |
| 510(k) Number (if known) K251139 | |
| Device Name KabiHelp® Uno KabiHelp® Advance plus | |
| Indications for Use (Describe) The KabiHelp® Bag is an empty container to be filled with components of parenteral nutrition and parenteral nutrition related medication to be administered to the patients using an intravascular administration set. Parenteral nutrition and parenteral nutrition related medication transfer in and out of the container is done using aseptic technique. | |
| Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | |
| CONTINUE ON A SEPARATE PAGE IF NEEDED. | |
| This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* | |
| The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov | |
| "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." | |
{4}
FRESENIUS KABI
January 9, 2026
K251139 - 510(k) Summary
## Contact Details
Applicant Name
Fresenius Kabi AG
Applicant Address
Else-Kröner-Str. 1
Bad Homburg 61352
Germany
Correspondent Name
Fresenius Kabi
Correspondent Address
Three Corporate Drive
Lake Zurich, IL 60047
United States
Correspondent Contact Telephone
847-550-2929
Correspondent Contact
Rhoda Lynn Valera
Correspondent Contact Email
rhoda.valera@fresenius-kabi.com
## Device Name
Device Trade Name
KabiHelp® Uno
KabiHelp® Advance plus
Common Name
I.V. container
Classification Name
Container, I.V.
Regulation Number
880.5025
Product Code
KPE
## Legally Marketed Predicate Device
Predicate 510(k) Number
K210749
Predicate Trade Name
Empty EVA Bag
Product Code
KPE
Page 1 of 6
{5}
Page 2 of 6
# Device Description Summary
The KabiHelp® Bag is an empty plastic container to be filled with components of parenteral nutrition and parenteral nutrition related medication to be administered to patients using an intravascular administration set. It is designed to be used with KabiHelp Pro Compounding System and KabiHelp Transfer Sets and Accessories.
Filling of the bags takes place in an aseptic environment. The bags are available in monolayer or multilayer models in various volumes.
All KabiHelp bags are equipped with three port types: (1) a filling port suitable for the KabiHelp Transfer Sets, (2) an injection port for manual injection of additives, and (3) an administration port for infusion therapy.
# Intended Use/Indications for Use
The KabiHelp® Bag is an empty container to be filled with components of parenteral nutrition and parenteral nutrition related medication to be administered to the patients using an intravascular administration set. Parenteral nutrition and parenteral nutrition related medication transfer in and out of the container is done using aseptic technique.
# Indications for Use Comparison
The Indications for Use between the subject device and the predicate device is the same as they are both used for solution preparation and administration using aseptic technique. The KabiHelp bag is used for parenteral nutrition components and parenteral nutrition-related medication, which do not constitute a new intended use.
# Technological Comparison
The following table provides a comparison between the subject and predicate devices:
| Description | Subject Device KabiHelp Bag | Predicate Device Empty EVA Bag (K210749) | Discussion |
| --- | --- | --- | --- |
| Indications for Use | The KabiHelp Bag is an empty container to be filled with components of parenteral nutrition and parenteral nutrition related medication and to be administered to the patients using an intravascular administration set. Parenteral nutrition and parenteral nutrition related medication transfer in and out of the container is done using aseptic technique. | The Empty EVA Bag is an empty container used for administration of solutions to the patients using an intravascular administration set. Medication transfer in and out of the container is done using aseptic technique. | Different Slight verbiage difference but both are used for solution preparation and administration using aseptic technique. |
{6}
| Description | Subject Device
KabiHelp Bag | Predicate Device
Empty EVA Bag
(K210749) | Discussion |
| --- | --- | --- | --- |
| Regulation Number | 880.5025 | 880.5025 | Same |
| Product Code | KPE | KPE | Same |
| Classification Name | I.V. Container | I.V. Container | Same |
| Material | EVA (Ethylene vinyl acetate)
PVC (Polyvinyl Chloride)
ABS (Acrylonitrile Butadiene Styrene)
PS (Polystyrene)
EVOH (Ethylene vinyl alcohol)
Blue Ink
While Dye
Green Dye | EVA (Ethylene vinyl acetate)
PVC (Polyvinyl Chloride)
ABS (Acrylonitrile Butadiene Styrene)
PP (Polypropylene)
SBC (Styrene Butadiene Copolymer)
MABS (Methyl Methacrylate Acrylonitrile Butadiene Styrene)
Thermoplastic Elastomer
Yellow Dye
Blu Dye | Different
The biocompatibility data provided demonstrates that the subject device is as safe and effective as the predicate device, and the material differences do not raise any new issues of safety and effectiveness. |
| Biocompatibility | Meet requirements for ISO 10993-1 | Meet requirements for ISO 10993-1 | Same |
Page 3 of 6
{7}
| Description | Subject Device KabiHelp Bag | Predicate Device Empty EVA Bag (K210749) | Discussion |
| --- | --- | --- | --- |
| Design | The KabiHelp Bag has the following configuration: - with three tubes: (1) a fill port to fill the container (2) injection port for additions of other medications and (3) a spike port to connect intravascular administration set; after filling the bag is clamped by means of non-reopening clamp to secure the contents before administration. The KabiHelp Bag is available in monolayer EVA or multilayer EVA/EVOH. | The Empty EVA bag has the following configurations: - with three tubes: (1) a fill port to fill the container, (2) injection port for additions of other medications and (3) a spike port to connect intravascular administration set; after filling the bag is clamped by means of non-reopening clamp to secure the contents before administration. - with one tube, used both for the filling of the bag and the administration of the solution to the patient; after filling the bag is clamped by means of a pinch clamp and closed with the sealing cap to secure the contents prior to Administration. The Empty EVA Bag is available in monolayer EVA. | Different The subject device and the predicate device both offer a three-tube configuration with the same types of ports. Both devices also offer a monolayer EVA variant. The scientific data provided demonstrates that the subject device is as safe and effective as the predicate device, and the variant differences do not raise any new issues of safety and effectiveness. |
| Sterilization | SAL 10-6, Ethylene oxide (EO) sterilization | SAL 10-6, Radiation | Different The subject device and the predicate device have the same Sterility Assurance Level (SAL). EO and Radiation belong to the same Established Category A sterilization method. |
| Reusable | No | No | Same |
{8}
| Description | Subject Device
KabiHelp Bag | Predicate Device
Empty EVA Bag
(K210749) | Discussion |
| --- | --- | --- | --- |
| Packing Pouch | Tyvek for EO sterilization | Polyethylene (LDPE) for gamma sterilization | Different
The sterilization data provided demonstrates that the subject device is as safe and effective as the predicate device, and the packaging material difference does not raise any new issues of safety and effectiveness. |
The technological characteristics of the subject device were compared with publicly available information on the predicate device. Differences were analyzed and verified through testing, showing no additional concerns and demonstrating that the subject device is substantially equivalent to the predicate device.
## Non-Clinical and/or Clinical Tests Summary & Conclusions
The nonclinical tests were conducted on the subject device according to the following standards in order to demonstrate substantial equivalence with the predicate device:
1. Biocompatibility Testing according to ISO 10993-1:2018 Biological evaluation of medical devices, Evaluation and testing within a risk management process. The following biocompatibility tests were performed:
- Cytotoxicity ISO 10993-5:2009 Biological evaluation of medical devices – Part 5: Tests for invitro-cytotoxicity
- Sensitization ISO 10993-10:2021 Biological evaluation of medical devices – Part 10: Tests for irritation and skin sensitization
- Irritation or Intracutaneous Reactivity ISO 10993-23:2021 Biological evaluation of medical devices – Part 23: Test for irritation
- Acute Systemic Toxicity ISO 10993-11:2017 Biological evaluation of medical devices – Part 11: Tests for systemic toxicity
- Subacute/Subchronic Toxicity ISO 10993-11:2017 Biological evaluation of medical devices – Part 11: Tests for systemic toxicity
- Material-Mediated Pyrogenicity USP <151> Pyrogen Test (Rabbit Test)
- Hemolysis ASTM F756:2017 Standard Practice for Assessment of Hemolytic Properties of Materials
2. Applicable Requirements according to ISO 15747:2018 Plastic containers for intravenous injection
3. Particulate matter according to USP <788> Particulate Matter in Injections
4. Chemical testing according to ISO 15747:2018 Plastic containers for intravenous injections
Page 5 of 6
{9}
5. The package integrity testing according to ISO 11607-1:2019 Packaging for terminally sterilized medical devices – Requirements for materials, sterile barrier systems and packaging systems
6. Human Factors Study according to Applying Human Factors and Usability Engineering to Medical Devices Guidance for Industry and Food and Drug Administration Staff, issued February 2016
No clinical study has been conducted on the subject device.
## Substantial Equivalence
All the necessary safety and performance tests conducted on the subject device demonstrated that the KabiHelp Bag is substantially equivalent to the predicate device, particularly regarding its intended use and technological characteristics. The minor differences between the devices do not raise any new issues of safety or effectiveness.
Page 6 of 6
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.