K222425 · Ellusa, LLC · GEI · Sep 8, 2022 · General, Plastic Surgery
Device Facts
Record ID
K222425
Device Name
Ellusa Reusable Neutral Plates
Applicant
Ellusa, LLC
Product Code
GEI · General, Plastic Surgery
Decision Date
Sep 8, 2022
Decision
SESE
Submission Type
Special
Regulation
21 CFR 878.4400
Device Class
Class 2
Indications for Use
The Reusable Neutral Plate provides a safe return path for electrosurgical current and is designed for use with Ellusa Generators for minor surgical applications. The Reusable Neutral Plate is provided nonsterile and intended for use only in nonsterile environments.
Device Story
Device is a flexible silicone rubber plate with a 10-foot cable; functions as a return electrode for monopolar electrosurgical current. Used in conjunction with Ellusa RF generators during minor surgical procedures. Provides a safe return path for high-frequency electrical current to prevent patient burns. Operated by clinicians in nonsterile clinical environments. Device is non-sterile and reusable. Output is the completion of the electrical circuit required for electrosurgical cutting and coagulation.
Clinical Evidence
No clinical data. Substantial equivalence demonstrated via bench testing, including electrical safety (IEC 60601-2-2) and biocompatibility (ISO 10993-5, ISO 10993-10).
Technological Characteristics
Flexible silicone rubber plate; 10-foot cable; monopolar RF energy return path. Tested to IEC 60601-2-2 (6th edition) for thermal effects, dielectric strength, and contact impedance. Biocompatibility per ISO 10993-5 and ISO 10993-10.
Indications for Use
Indicated for use as a return path for electrosurgical current during minor surgical procedures using Ellusa Generators. Intended for use in nonsterile environments.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
K251235 — Electrosurgical Pads · Baisheng Medical Co., Ltd. · Jun 19, 2025
K080741 — MEGA SOFT REUSABLE PATIENT RETURN ELECTRODE · Megadyne Medical Products, Inc. · Dec 16, 2008
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA) along with the Department of Health & Human Services. The FDA logo features a blue square with the letters "FDA" in white, followed by the words "U.S. FOOD & DRUG" in blue, and "ADMINISTRATION" in a smaller font size below. To the left of the FDA logo is the symbol of the Department of Health & Human Services, which consists of a stylized human figure.
September 8, 2022
Ellusa, LLC Ms. Suzanne Lucas Sr. Regulatory Affairs Specialist 2473 Grand Avenue Baldwin, New York 11510
Re: K222425
Trade/Device Name: Ellusa Reusable Neutral Plates Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical cutting and coagulation device and accessories Regulatory Class: Class II Product Code: GEI Dated: July 24, 2022 Received: August 11, 2022
Dear Ms. Lucas:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part
{1}------------------------------------------------
801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
for
Long Chen, Ph.D. Assistant Director DHT4A: Division of General Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K222425
Device Name Ellusa Reusable Neutral Plate
Indications for Use (Describe)
The Ellusa Reusable Neutral Plate provides a safe return path for electrosurgical current and is designed for use with Ellusa Generators for minor surgical applications. The Reusable Neutral Plate is provided nonsterile and intended for use only in nonsterile environments.
Type of Use (Select one or both, as applicable)
> Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2023 See PRA Statement below.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for "ellusa" in a bold, sans-serif font. A stylized swoosh design is placed to the left of the word, adding a dynamic element to the logo. The wordmark is clean and modern, with a focus on readability.
K222425
# Exhibit 6. 510(k) SUMMARY
(As required by 21 CFR 807.92(a))
## Date Prepared
September 7, 2022
# Submitter's Information (807.92(a)(1))
Company Name and Address: Ellusa, LLC 2473 Grand Avenue Baldwin, NY 11510 Phone: (516) 634-1370 Establishment Registration #: 3016087306
# Contact Information:
Ms. Suzanne Lucas Sr. Requlatory Affairs Specialist Phone: (516) 634-1370 Email: slucas@ellusa.com
### Device Information (807.92(a)(2))
Trade Name: Ellusa Reusable Neutral Plate
Common/Usual Name: Electrosurgical, Cutting & Coagulation Device & Accessories
Classification Name and Regulation: Electrosurgical Cutting and Coagulation Device and Accessories; 21 CFR 878.4400
Classification Panel: General and Plastic Surgery
# Device Class/Product Code
FDA Classification: Class 2 FDA Product Code: GEI
# Predicate Devices (807.92(a)(3))
- Ellusa Disposable Neutral Plate (K202562) ●
ellusa LLC. 2473 Grand Avenue, Baldwin, NY 11510 Main: (516) 654-4000 • Fax: (516) 654-8000 www.ellusa.com
{4}------------------------------------------------
K222425
Image /page/4/Picture/2 description: The image shows the word "ellusa" in a stylized, sans-serif font. To the left of the word is a curved, swooping design element that adds a dynamic touch to the logo. The font is modern and clean, with rounded edges that give it a friendly and approachable feel. The overall design is simple yet effective, creating a memorable and recognizable brand image.
# Device Description (807.92(a)(4))
The Ellusa Reusable Neutral Plates will be provided as a flexible plate made of silicone rubber and will be supplied with a 10-foot cable and is non-sterile. There are no differences in the functionality of a reusable neutral plate as compared to the disposable neutral plate. They are both used to provide a safe return path for electrosurgical current.
## Intended Use:
The Reusable Neutral Plate provides a safe return path for electrosurgical current and is designed for use with Ellusa RF Generators for minor surgical applications. The Reusable Neutral Plate is provided nonsterile and intended for use only in nonsterile environments.
## Substantial Equivalence Comparison (807.92(a)(6))
The Ellusa Reusable Neutral Plate is substantially equivalent in intended use, technological characteristics, operating principle, and performance characteristics to the predicate device by Ellusa (K202562).
| Predicate<br>Information | Ellusa Reusable Neutral Plate<br>(SUBJECT DEVICE) | Ellusa Disposable Neutral Plate<br>(K202562<br>(PREDICATE DEVICE) |
|---------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended Use | The Reusable Neutral Plate provides a safe<br>return path for electrosurgical current and is<br>designed for use with Ellusa Generators for<br>minor surgical applications. The Reusable<br>Neutral Plate is provided nonsterile and<br>intended for use only in nonsterile<br>environments. | The Neutral Plate/Grounding Pad is<br>designed for use with Ellusa Generators<br>and provides a safe return path for<br>electrosurgical current. |
| Product Code | GEI | GEI |
| Device Classification | Class II | Class II |
| Functions | Connect to Electrosurgical Generator to<br>provide safe return path. | Connect to Electrosurgical Generator to<br>provide safe return path. |
| Operating mode | Monopolar | Monopolar |
| Energy Source | RF Energy | RF Energy |
| Cable Length (ft) | 10 feet | 9 feet |
| Patient Contacting<br>Materials | Silicone | Silicone |
| Testing standards<br>used | IEC 60601-2-2 (6th edition) | IEC 60601-2-2 (6th edition) |
ellusa LLC. 2473 Grand Avenue, Baldwin, NY 11510 Main: (516) 654-4000 • Fax: (516) 654-8000 www.ellusa.com
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the text 'K222425' in a bold, sans-serif font. The text is black against a white background. The characters are evenly spaced and clearly legible.
Image /page/5/Picture/2 description: The image shows the word "ellusa" in a stylized font. The word is in all lowercase letters and is black. To the left of the word is a curved design that resembles a swoosh or a stylized "e". The font is sans-serif and has rounded edges, giving it a modern and clean look.
## Non-Clinical Testing (807.92(b)(1))
The Reusable Neutral Plates will be manufactured in accordance with the design control requirements of 21 CFR 820.30. Appropriate non-clinical verification and validation activities were planned and conducted to address identified risks and ensure the safety and effectiveness of the device. Testing was conducted for the following standard and resulted in passing results.
- -IEC 60601-2-2: 2017 - Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
- o IEC 60601-2-2: Cl. 201.8.7.3.101: Thermal effects of HF Leakage Currents
- IEC 60601-2-2: Cl. 201.8.8.3.103: ACTIVE ACCESSORY HF dielectric strength O
- IEC 60601-2-2: Cl. 201.8.8.3.104: ACTIVE ACCESSORY mains frequency dielectric strength O
- IEC 60601-2-2: Cl. 201.15.101.2: NE cord attachment O
- IEC 60601-2-2: Cl. 201.15.101.4: NE cord insulation o
- IEC 60601-2-2: Cl. 201.15.101.6: NE contact impedance O
The reusable neutral plate has been tested and evaluated against the following biocompatibility requirements. All tests resulted in passing results.
- In-Vitro Cytotoxicity ISO 10993-5:2010 o
- Sensitization ISO 10993-10:2010 O
- Irritation ISO 10993-10:2010 o
### Technological Characteristics
The devices are substantially equivalent to the predicate device based on a comparison of physical and performance characteristics. They are all intended to be used with electrosurgical generators to provide a safe return path for the electrosurgical current.
### Clinical Testing (807.92(b)(2))
This premarket submission did not rely on the assessment of clinical performance data to demonstrate substantial equivalence.
### Conclusion (807.92(b)(3))
In accordance with the Federal Food, Drug and Cosmetic Act, 21 CFR Part 807 and based on the similarity to the predicate devices in terms of technology, performance, and indications for use, Ellusa, LLC concludes that the subject device, Ellusa Reusable Neutral Plates do not raise any issues of safety or effectiveness and are substantially equivalent to the predicate device as described above.
ellusa LLC. 2473 Grand Avenue, Baldwin, NY 11510 Main: (516) 654-4000 • Fax: (516) 654-8000 www.ellusa.com
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.