LimFlow ARC

K221541 · LimFlow, Inc. · PDU · Aug 31, 2022 · Cardiovascular

Device Facts

Record IDK221541
Device NameLimFlow ARC
ApplicantLimFlow, Inc.
Product CodePDU · Cardiovascular
Decision DateAug 31, 2022
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1250
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The LimFlow ARC is intended to facilitate placement and positioning of guide wires and catheters within the peripheral vasculature. The LimFlow ARC is not intended for use in the coronary or cerebral vasculature.

Device Story

LimFlow ARC is a single-use percutaneous catheter designed to facilitate guidewire and catheter placement in peripheral vasculature; used in hospital or office-based cardiac catheter labs by physicians. Device consists of a cannula, catheter shaft, and deployment handle with a control slide. During procedures, the device is advanced through an indwelling vascular sheath to a target chronic total occlusion (CTO); advancement is monitored via external fluoroscopy. The physician uses the deployment handle to position the cannula to cross the occlusion. By facilitating guidewire navigation, the device assists in recanalization procedures, potentially improving blood flow in patients with peripheral vascular disease. The device is supplied sterile and is intended for short-term use (<24 hours).

Clinical Evidence

Bench testing only. No clinical data provided. Testing included biocompatibility (ISO 10993-1, 21 CFR Part 58), dimensional verification, joint tensile strength, torqueability, torque to failure, flex/kink testing, simulated use, and packaging/sterilization validation.

Technological Characteristics

Percutaneous catheter; 6F outer diameter; 100 cm length; 10 mm cannula throw; 22-gauge cannula opening. Materials: medical-grade metals and polymers. Energy: manual mechanical actuation. Connectivity: none. Sterilization: Ethylene Oxide (EO).

Indications for Use

Indicated for patients requiring placement and positioning of guide wires and catheters within the peripheral vasculature. Contraindicated for use in coronary or cerebral vasculature.

Regulatory Classification

Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ August 31, 2022 Image /page/0/Picture/1 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue. LimFlow, Inc. Zachary Woodson VP of Regulatory Affairs & Quality 3031 Tisch Way - 110 Plaza West San Jose. California 95128 ### Re: K221541 Trade/Device Name: LimFlow ARC Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: PDU Dated: May 26, 2022 Received: May 27, 2022 ### Dear Zachary Woodson: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies.combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801): medical device reporting of medical device-related adverse events) (21 CFR 803) for {1}------------------------------------------------ devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrl-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely. for Lydia Glaw Assistant Director DHT2C: Division of Coronary and Peripheral Intervention Devices OHT2: Office of Cardiovascular Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K221541 Device Name LimFlow ARC Indications for Use (Describe) The LimFlow ARC is intended to facilitate placement and positioning of guidewires and catheters within the peripheral vasculature. The LimFlow ARC is not intended for use in the coronary or cerebral vasculature. | Type of Use (Select one or both, as applicable) | |-------------------------------------------------| |-------------------------------------------------| X Prescription Use (Part 21 CFR 801 Subpart D) | Over-The-Counter Use (21 CFR 801 Subpart C) #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ #### LimFlow ARC™ # 510(k) Summary 21 CFR807.92 #### Submitter Information Applicant: Address E-mail: Contact: Phone Number: Contact e-mail: Date Prepared: Contact Phone Number: LimFlow Inc. 3031 Tisch Way 110 Plaza West San Jose, CA 95127 +1 (888) 478-7705 info@limflow.com Zachary Woodson zwoodson@limflow.com +1 (707) 328-6522 26 May 2022 ### Proposed Device | Trade Name: | LimFlow ARC | |----------------------|----------------------------------------| | Common name: | Percutaneous catheter | | Classification name: | Catheter for Crossing Total Occlusions | | Classification: | Class II | | Regulation: | 21 CFR 870.1250 | | Product Code: | PDU | #### Predicate Device | Trade Name: | OUTBACK® Elite Re-Entry Catheter | |-------------------------|--------------------------------------------------------------------------| | Common name: | Percutaneous catheter | | Classification name: | Catheter for Crossing Total Occlusions | | Classification: | Class II | | Regulation: | 21 CFR 870.1250 | | Product Code: | PDU | | Premarket Notification: | K150836<br>Note: This predicate device has not been subject to a recall. | ### Device Description The LimFlow ARC is a single-use device designed to facilitate placement and positioning of quide wires within the peripheral vasculature. The device consists of three primary elements: 1) Cannula, 2) Catheter shaft, and 3) Deployment handle with deployment control slide. The LimFlow ARC is used in a healthcare facility, such as a cardiac catheter lab or hospital. It is in contact with patient tissue for less than 24 hours and is made of materials that are biocompatible. The LimFlow ARC is supplied sterile. {4}------------------------------------------------ ## Intended Use/Indications For Use The LimFlow ARC is intended to facilitate placement and positioning of guide wires and catheters within the peripheral vasculature. The LimFlow ARC is not intended for use in the coronary or cerebral vasculature. ### Comparison of Technological Characteristics with the Predicate Device The LimFlow ARC is substantially equivalent to the predicate device based upon the following similarities: - . Both devices are intended to be used to cross chronic total occlusions (CTOs) in peripheral vessels - Both devices are used in cardiac catheter labs in either a hospital or an ● office-based lab - Both devices are advanced to the target occlusion through an ● indwelling vascular sheath - Advancement of both devices is monitored by external fluoroscopy ● - . Both devices have equivalent sizes in terms of outer diameter and working length of the cannula - . Both devices share the same basic design, mechanism of action, and principles of operation - Both devices share the same sterilization method (EO) ● The table below compares the LimFlow ARC (this submission) to the predicate device, the Outback Elite (K150836). | Device Feature | OUTBACK Elite (Predicate) | LimFlow ARC (This Submission) | |-----------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Device Classification | Class II | Same | | Classification Name | Catheter for Crossing Total Occlusions (21 CFR<br>870.1250) | Same | | Device Category | Percutaneous catheter | Same | | Indications for Use | The OUTBACK Elite is intended to facilitate<br>placement and positioning of guide wires and<br>catheters within the peripheral vasculature. The<br>OUTBACK Elite is not intended for use in the<br>coronary or cerebral vasculature. | Same | | Device Description: Design<br>& Operating Principle | The OUTBACK Elite is a single-use device designed<br>to facilitate placement and positioning of guide wires<br>within the peripheral vasculature. The device<br>consists of three primary elements: 1) Cannula, 2)<br>Catheter shaft, and 3) Deployment handle with<br>deployment control slide. The OUTBACK Elite Re-<br>Entry Catheter is supplied sterile and is available in<br>two usable lengths (80 cm and 120 cm). | Same, except the is available in one usable<br>length (100 cm). | | Packaging Contents | One (1) OUTBACK Elite | Same | | Device Feature | OUTBACK Elite (Predicate) | LimFlow ARC (This Submission) | | Contraindications | The OUTBACK Elite is not intended for use in the<br>coronary or cerebral vasculature. | Same | | Where used | Hospital or office-based lab | Same | | Technological<br>Characteristics | The OUTBACK Elite consists of three primary<br>elements:<br>1) 22-gauge nitinol re-entry cannula<br>2) Catheter shaft<br>3) Deployment handle with deployment control slide<br><br>Key features of the OUTBACK Elite Re-Entry<br>Catheter include:<br>- 6F sheath compatibility<br>- 0.014" guide wire compatibility<br>- Hydrophilic coating along the entire length of the<br>catheter<br>- Ergonomic Handle<br>- Radiopaque markers at the distal end that<br>enables lumen orientation under fluoroscopy | Same, except the LimFlow ARC does not<br>contain a hydrophilic coating. | | Guide wire compatibility | The OUTBACK Elite is recommended for use with<br>the following guide wires:<br>Cordis ATW 0.014"<br>Cordis STABILIZER® Plus 0.014"<br>Cordis STABILIZER® XS 0.014"<br>Boston Scientific Platinum Plus 0.014"<br>Boston Scientific Choice Extra Support 0.014"<br>Boston Scientific Mailman 0.014"<br>Boston Scientific Luge 0.014" | The LimFlow ARC is recommended for use with<br>the following crossing guide wires:<br>Boston Scientific Thruway 0.014"<br>Medtronic Nitrex 0.014"<br>Terumo Runthrough 0.014" | | Duration of use per<br>ISO 10993-1 | Externally communicating medical device in contact<br>with circulating blood for ≤ 24 hrs. | Same | | Target Population | Patients requiring placement and positioning of guide<br>wires and catheters in the peripheral vasculature. | Same | | Anatomical Sites | Cardiovascular system | Cardiovascular system | | Key Dimensions | Catheter OD<br>6 French | Catheter OD<br>Same | | | Catheter Length<br>80 cm or 120 cm | Catheter Length<br>100 cm | | | Cannula Throw<br>8 mm | Cannula Throw<br>10 mm | | | Cannula Opening<br>22-gauge | Cannula Opening<br>Same | | Materials | Medical grade metals and polymers | Same | | Sterilization Method | Ethylene Oxide | Same | | Performance & Test data | Biocompatibility per 21 CFR Part 58 and per<br>ISO 10993-1, including:<br>- Dimensional and Functional Testing, including:<br>o Device Joint Tensile Strength<br>o Catheter Torqueability<br>o Device Joint Torque to Failure<br>- Packaging Validation<br>- Sterilization Validation | Same | {5}------------------------------------------------ {6}------------------------------------------------ ## Performance Data The following performance data were provided to establish that the LimFlow ARC does not raise new questions of safety or effectiveness compared o the predicated OUTBACK Elite cleared under K150836: ## Biocompatibility Testing Biocompatibility testing was performed on finished and sterilized LimFlow ARC in compliance with the U.S. Food and Drug Administration Good Laboratory Practice (GLP) regulations set forth in 21 CFR Part 58 and ISO 10993-1 Biological evaluation of medical devices - Part 1. Biocompatibility testing included the following: - Cytotoxicity ● - Hemolysis ● - Complement Activation ● - Intracutaneous Irritation ● - Maximum Sensitization ● - Acute Systemic Toxicity ● - Pyrogenicity ● - Partial Thromboplastin Time ● - Thrombogenicity ● ### Device Dimensional and Functional Testing - Dimensional Verification ● - Device Joint Tensile Strength ● - Catheter Torqueability ● - Device Joint Torque to Failure - Flex / Kink Testing ● - Simulated Use ### Packaging and Sterilization Testing - Packaging Validation - . Sterilization Validation ### Conclusions The information submitted in this premarket notification confirms the LimFlow ARC raises no new questions of safety and effectiveness and meets the requirements that are considered essential for its intended use and that the LimFlow AR is substantially equivalent to the predicate device, OUTBACK Elite.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...