The PRO M CLASS is used by dental professionals for orthodontic procedures using a root canal instrument and tightening and loosening an abutment screw to fix and remove the abutment on a dental implant in prosthodontic treatment.
Device Story
PRO M CLASS is an AC-powered dental handpiece system comprising a motor handpiece, contra-angle handpiece, charger, and AC/DC adapter. Device operates by converting AC power to DC 5.0V via a controller, which drives a micromotor to provide rotational power to a contra-angle handpiece. Dental professionals use the device for grinding, cutting, polishing, and screw-driver tasks. Operators control speed, torque, and rotation direction (forward/reverse) via the controller. The device facilitates orthodontic and endodontic procedures and the fixation/removal of dental implant abutments. It is intended for use by dental professionals in clinical settings. The system benefits patients by enabling precise mechanical manipulation of dental instruments and implant components.
Clinical Evidence
Bench testing only. Performance verified via electrical safety (IEC 60601-1), electromagnetic compatibility (IEC 60601-1-2), and mechanical performance (ISO 14457). Sterilization validated per ISO 17665-1. No clinical data presented.
Technological Characteristics
AC-powered micromotor system; Li-Ion battery (DC 3.7V, 800mAh); contra-angle handpiece with SUS420 head/chuck; ISO 1797-1 Type 1/3 chuck design; ISO 3964 coupling; sterilization via autoclave (135°C).
Indications for Use
Indicated for dental professionals performing orthodontic/endodontic procedures using root canal instruments and tightening/loosening abutment screws for dental implants in prosthodontic treatment.
Regulatory Classification
Identification
A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.
Cordless Prosthodontic Screwdriver with Torque Calibration System, Model iSD900 (K110278)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.
September 19, 2022
Saeyang Microtech Co., Ltd. % DongHa Lee RA Consultant KMC, Inc Room no. 1709, 123, Digital-ro 26-gil, Guro-gu, Seoul 08390 SOUTH KOREA
Re: K213897
Trade/Device Name: Pro M Class Regulation Number: 21 CFR 872.4200 Regulation Name: Dental Handpiece And Accessories Regulatory Class: Class I, reserved Product Code: EKX Dated: June 16, 2022 Received: June 21, 2022
Dear Yeon Woo:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's
{1}------------------------------------------------
requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Michael E. Adjodha, M. ChE. Assistant Director DHT1B: Division of Dental and ENT Devices OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT and Dental Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K213897
Device Name
PRO M CLASS
Indications for Use (Describe)
The PRO M CLASS is used by dental professionals for orthodontic procedures using a root canal instrument and tightening and loosening an abutment screw to fix and remove the abutment on a dental implant in prosthodontic treatment.
Type of Use (Select one or both, as applicable)
| <span> <span style="font-size: 1em;">☑</span> Prescription Use (Part 21 CFR 801 Subpart D) </span> |
|------------------------------------------------------------------------------------------------------|
|------------------------------------------------------------------------------------------------------|
| <span> <span style="font-size: 1em;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) </span> |
|-----------------------------------------------------------------------------------------------------|
|-----------------------------------------------------------------------------------------------------|
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
## V. 510(k) Summary (K213897)
This summary of 510(K) - substantial equivalence information is being submitted in accordance with requirements of 21 CFR Part 807.92.
Date: June 16, 2022
### 1. Applicant / Submitter
Saeyang Microtech Co., Ltd. 348, Seongseo-ro, Dalseo-gu, Daegu, Republic of Korea, Tel: +82-53-582-9000~2
## 2. Submission Correspondent
DongHa Lee (Consultant, KMC, Inc.) Address: Room no. 1709, 123, Digital-ro 26-gil, Guro-gu, Seoul, 08390, South Korea Tel: +82-70-8965-5554 Fax: +82-2-856-5904 Email: dhlee@kmcerti.com
### 3. Device
| ■ Trade Name: | PRO M CLASS |
|--------------------------------|-----------------------------------|
| ■ Common Name: | AC-Powered Direct Drive Handpiece |
| ■ Classification Name: | Dental handpiece and accessories |
| ■ Classification Product Code: | EKX |
| ■ Classification Regulation: | 21 CFR 872.4200 |
| ■ Device Class: | Class I |
### 4. Predicate Device
- Predicate Devices: (K111616) E-CUBE
### ■ Reference Devices: (K161500) MEG-TORQ (K110278) Cordless Prosthodontic Screwdriver with Torque Calibration System, Model iSD900
{4}------------------------------------------------
### 5. Description
### ■ General
The PRO M CLASS is an AC-powered device that includes a 'Motor Handpiece', 'Contra angle Handpiece', 'Charger unit' and 'AC/DC Adaptor' for grinding, cutting, polishing and screw driver work in dental oral use.
[Note] The Dental Bur is not provided with the subject device.
### ■ Technological Characteristics
The PRO M CLASS uses the battery inside the motor handpiece as a power source to rotate the micromotor to transmit the generated rotational power to the contra angle. Dental treatment is performed using the rotational power obtained by this.
### . Principle of Operation
The motor turned by the power converted into DC 5.0V by controller delivers its turning power to the file through spin to perform punching, cutting and removing functions. The hand-piece can be operated, stopped and set/adjusted on/in its speed, torque and turning direction by handling of the controller.
#### 6. Indication for use
The PRO M CLASS is used by dental professionals for orthodontic procedures using a root canal instrument and tightening and loosening an abutment screw to fix and remove the abutment on a dental implant in prosthodontic treatment.
### 7. Basis for Substantial Equivalence
The PRO M CLASS is substantially equivalent to the predicate device in terms of intended use, technical & performance characteristic, electrical power, design, and function.
Also, the Indications for Use for the subject devices is identical to the predicate device (K111616) for endodontic and orthodontic procedure in dental oral use, and the reference devices (K161500, K110278) for screw-driver function in dental implant in prosthodontic treatment.
The electrical safety and performance testing performed on the subject device demonstrate that the difference in external design and some technological characteristics compared predicate device does not raise any new issues.
The sterilization validation performed on the subject device demonstrates that the difference in sterilization method does not raise any new issues. Any of difference (chuck design and lubricant) also does not raise any new issues of safety and effectiveness as compared to the predicate device.
Based on the comparison charts below and test results provided in this submission, we conclude that the subject device is substantially equivalent to the predicate device.
{5}------------------------------------------------
| 510(k) No. | Subject Device | Predicate Device | Reference Device 1 | Reference Device 2 | Comparison |
|----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------|
| | Not yet | K111616 | K161500 | K110278 | |
| Device Name | PRO M CLASS | E-CUBE | MEG-TORQ | Cordless Prosthodontic<br>Screwdriver with Torque<br>Calibration System, Model<br>iSD900 | |
| Manufacturer | Saeyang Microtech Co., Ltd. | Saeshin Precision Co., Ltd. | MICRO-NX Co., Ltd. | Nakanishi, Inc. | |
| Regulation<br>Number | 21 CFR 872.4200 | 21 CFR 872.4200 | 21 CFR 872.4200 | 21 CFR 872.4200 | Same |
| Product Code | EKX | EKX | EKX | EKX | Same |
| Regulatory Class | Class I | Class I | Class I | Class I | Same |
| Use | RX only | RX only | RX only | RX only | Same |
| Indications for<br>Use Statement | The PRO M CLASS is used by dental<br>professionals for orthodontic and<br>endodontic procedures using a root<br>canal instrument and tightening and<br>loosening an abutment screw to fix and<br>remove the abutment on a dental<br>implant in prosthodontic treatment. | The E-CUBE is indicated for<br>use by dentists in standard<br>endodontic procedures<br>using rotary endodontic<br>files and rotary endodontic<br>drills (Gates-Glidden). | This product is a cordless<br>motor handpiece system<br>intended for tightening and<br>loosening an abutment<br>screw to fix and remove the<br>abutment on a dental<br>implant in prosthodontic<br>treatment. | This product is a cordless<br>motor handpiece system<br>intended for tightening and<br>loosening an abutment<br>screw to fix and remove the<br>abutment on a dental<br>implant in prosthodontic<br>treatment. | Similar 1) |
| Component | Contra-Angle Handpiece<br>Motor Handpiece<br>Charger<br>Adapter | Contra-Angle Handpiece<br>Motor Handpiece<br>Controller,<br>Adapter | Contra-Angle Handpiece<br>Motor Handpiece<br>Charger<br>Adapter | Contra-Angle Handpiece<br>Motor Handpiece<br>Charger | Same |
| Operational<br>Mode | Speed control, Torque control, Rotate<br>both forward/reverse operation | Speed control, Torque<br>control, Rotate both<br>forward/reverse operation | Speed control, Torque<br>control, Rotate both<br>forward/reverse operation | Speed control, Rotate both<br>forward/reverse operation | Same |
| Principle of<br>Operation | The motor turned by the power<br>converted into DC voltage by controller<br>delivers its turning power to the file<br>through spin to perform punching,<br>cutting and removing functions. The<br>hand-piece can be operated stopped<br>and set/adjusted on/in its speed,<br>torque and turning direction by<br>handling of the controller. | The motor turned by the<br>power converted into DC<br>voltage by controller<br>delivers its turning power to<br>the file through spin to<br>perform punching, cutting<br>and removing functions.<br>The hand-piece can be<br>operated stopped and<br>set/adjusted on/in its<br>speed, torque and turning<br>direction by handling of the<br>controller. | The motor turned by the<br>power converted into DC<br>voltage by controller<br>delivers its turning power<br>to the file through spin to<br>perform punching, cutting<br>and removing functions.<br>The hand-piece can be<br>operated stopped and<br>set/adjusted on/in its<br>speed, torque and turning<br>direction by handling of the<br>controller. | The motor turned by the power<br>converted into DC voltage by<br>controller delivers its turning power<br>to the file through spin to perform<br>punching, cutting and removing<br>functions. The hand-piece can be<br>operated stopped and<br>set/adjusted on/in its speed, torque<br>and turning direction by handling of<br>the controller. | Same |
| Electrical Safety | Complied with IEC 60601-1 | Complied with IEC 60601-1 | Complied with IEC 60601-1 | Complied with IEC 60601-1 | Same |
{6}------------------------------------------------
| ectromagnet Compatibility | | omplied with IEC 60601-1-2 | | | | omplied with IEC 60601-1 | omplied with IEC 60601- | Complied with IEC 60601 | Same |
|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|-------------------------------|-------------------------------------------------------------|---------|-------|---------------------------|-------------------------|------------------------------------------------------------------|--------------|
| | | | | | | | | | |
| evice Design – Motor Handpiece Battery Type | | Li-Ion (DC 3.7 V, 800 | nAH | | | None | i-Polyme | hium (DC 2.4V, 0.3V | Different 2) |
| | | 4:1 | | | 1:1 | 4:1 | | | |
| ាន សាសនា សាសនា សាសនា ន ការបោយសារ ប្រជាជាតិ ស្រុកស្រុក ប្រចាំប្រជាជាតិ | 00010 5000 z | 5 1901 EOO | | | 3,000 | 3,250 | | | |
| | | | | - | | 1.3 | | | |
| | | | 160:1 | - | - | - | None | - | |
| | | | 15-70 | - | - | - | 15-60 | - | |
| שלו או האירופי מערשים של מערכת משום של מערכת של המונים של המועד של המושב של המושב של המושב של המושב של המושב של המושב של המושב של המושב של המושב של המושב של המושב של המושב ש | | | 5-35 | । | | | 5-35 | | |
| | I | | | 320:1 | - | - | | None | |
| | | | | 15-25 | 1 | 1 | - | 15-25 | |
| וני שנים מורים חיצוניים | | | | 10-40 | 1 | | | 10-40 | |
| | | | | | | | | | |
| evice Design – Contra-Angle Handpier | | JS303F, SUS420 Head and Chuck | (는<br>( | | | S303F, SUS42 ead and Chuc | Jnknowi | Jnknowi | Same |
| huk Desig | | | ype 1 by ISO 1797-1 ype 3 by ISO 1797-1 ype 3 by ISO 1797-1 | | | ype 1 by ISO 1797- | ype 1 by ISO 1797- | ype 1 by ISO 1797 | Same |
| Coupling Dimensio | | | omplied with ISO 3964 | | | omplied with ISO 396 | omplied with ISO 39 | omplied with ISO 396 | Same |
| terilizatic | | utoclave by User at 135℃ for | Non-sterile | | | 32°C for 4min | | Non-sterile Lutoclave by User 1℃ for 20min or<br>32°C for 15mir | Different |
| evice Design – Charger & Adapte | | | | | | | | | |
| Input | | AC 100-240V, 50~60 Hz, 0.6A | | | | 100-240V, 47-63H | AC 100 ~ 240V, 50~60 | AC 100 ~ 240V, 50~60 H | Different |
| ubrican | | | | | | | | | |
| ាក កន្លង់ អ្នកន្ទនា រហូត ក្រុងប្រទេ ការចេញពី ព្រះបាទប្រយោ ។ សាខា សាសនា របស់ប្រយោ ។ | | na-Spray made by | | K052700 | | Inknow | Jnknow | Jnknow | Different |
{7}------------------------------------------------
| Substantial Equivalence Discussion |
|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Discussion |
| Similar 1)<br>The subject device has two main indications for use. The indications for use is based on the motor rotation speed and torque according to the gear ratio.<br>First indication for use is for orthodontic and endodontic procedures is the same as the predicate device (K111616)<br>Second indication for use is for tightening and loosening an abutment screw to fix and remove the abutment on a dental implant in prosthodontic treatment is the same as the reference devices (K161500, K110278). |
| Different 2)<br>The motor handpiece is supplied power from the internal rechargeable battery and battery voltage is the different.<br>The different was verified according to IEC 60601-1, IEC 80601-2-60 and IEC 62133-2. The testing results show that the difference does not raise any problems in the safety and effectiveness. |
| Similar 3)<br>Motor rotation speed as 2,000-10,000 rpm (on gear ratio 1:1) and 500-2,500 rpm (on gear ratio 4:1) are for orthodontic and endodontic procedures. It is similar to the predicate device (K111616).<br>Motor rotation speed as 15-70 rpm (torque 5-35 on gear ratio 160:1) is for prosthodontic treatment as tightening and loosening an abutment screw to fix and remove. It is similar to the reference device1 (K161500).<br>Motor rotation speed as 15-25 rpm (torque 10-40 on gear ratio 320:1) is for prosthodontic treatment as tightening and loosening an abutment screw to fix and remove. It is the same as the reference device2 (K110278).<br>Performance test (Bench test) according to ISO 14457 also was conducted. The testing results show that the difference does not raise any problems in the safety and effectiveness. |
| Different 4)<br>The Sterilization method is slightly different from the predicate device (K111616). The sterilization was validated according to ISO 17665-1 and the differences in sterilization methods show that it does not raise any problems in the safety and effectiveness. |
| Different 5)<br>The charger is supplied power from an AC/DC adapter. The power input of the AC/DC adapter is different from the predicate device (K111616). The different was verified according to IEC 60601-1, IEC 80601-2-60 and IEC 60601-1-2. The testing results show that the difference does not raise any problems in the safety and effectiveness. |
| Different 6)<br>The subject device uses a legally-marketed lubricant (K052700). It has been evaluated and cleared by FDA about the safety and effectiveness. |
| Conclusion<br>The PRO M CLASS is substantially equivalent to the predicate device and the reference devices in terms of intended use, technical & performance characteristic and function.<br>Also, the Indications for Use for the subject devices is identical to the predicate device (K111616) for endodontic and orthodontic procedure in dental oral use, and the reference devices (K161500, K110278) for screw-driver function in dental implant in prosthodontic treatment.<br>The electrical safety and performance testing performed on the subject device demonstrate that the difference in some technological characteristics compared predicate device and reference devices does not raise any new issues |
{8}------------------------------------------------
The steriizitor perforned on the subject eleves that the diference in take an taise any niel ifse any nifaste, any nifines any nifines any nifines any nifines any nifine is c
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.