KISS Dynamic Back Support, KISS Dynamic Solid Drop Seat
K211919 · Kinetic Innovative Seating System, LLC · KNN · Mar 4, 2022 · Physical Medicine
Device Facts
Record ID
K211919
Device Name
KISS Dynamic Back Support, KISS Dynamic Solid Drop Seat
Applicant
Kinetic Innovative Seating System, LLC
Product Code
KNN · Physical Medicine
Decision Date
Mar 4, 2022
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3920
Device Class
Class 1
Attributes
Therapeutic
Indications for Use
The KISS devices are wheelchair components intended for medical purposes that are generally sold as an integral part of a wheelchair but may also be sold separately as a replacement part. The KISS devices are intended to assist posture and positioning for a person seated in a wheelchair by way of providing a solid seating platform or back support with dynamic motion.
Device Story
KISS Dynamic Solid Drop Seat and Back Support are wheelchair components providing dynamic postural support. The seat replaces standard cloth wheelchair seats with a solid platform mounted on springs and low-friction Delrin pivot blocks; it translates weight shifts (up/down, side-to-side) into motion to disperse pressure and absorb impact. The back support features a fixed lumbar section and a spring-loaded upper backrest that flexes up to 30 degrees rearward in response to force, assisting the user back to an upright position. Used in clinical or home settings, these devices are operated by the wheelchair user. Healthcare providers use the output—improved postural support and pressure dispersion—to manage patient positioning. The devices benefit patients by reducing static pressure and facilitating movement, potentially increasing comfort during long-term sitting.
Clinical Evidence
No clinical trials were conducted. Evidence is based on bench testing, including ISO 16840-3 (load strength), RESNA WC-1 (stability/maneuverability), ISO 898-7 (fastener durability), and ISO 10993-10 (biocompatibility). Loaded deflection testing determined optimal spring placement. A customized bench test evaluated the influence of the seat on wheelchair cushion force-deflection. Ignition resistance testing (ISO 16840-10) showed partial failure regarding smoke emission duration. Clinical data is limited to observations that the technology does not negatively affect interface pressure and may reduce peak interface pressures during propulsion.
Indicated for individuals seated in a wheelchair requiring postural support and positioning assistance. Suitable for use with manual wheelchairs 16"-20" wide with tubular frames 7/8" to 1-1/8" diameter. Contraindicated for use on certain ultralight wheelchair models due to rigid frame design; users must observe stability limitations.
Regulatory Classification
Identification
A wheelchair component is a device intended for medical purposes that is generally sold as an integral part of a wheelchair, but may also be sold separately as a replacement part. Examples of wheelchair components are the following: Armrest, narrowing attachment, belt, extension brake, curb climber, cushion, antitip device, footrest, handrim, hill holder, leg rest, heel loops, and toe loops.
Tilt Adjustable Back Recline Seating System by Labac Systems (K923364)
Reference Devices
Quickie suspension wheelchair series model XTR with Rock Shox monoshock suspension (K982989)
Quickie and Zippie Series wheelchair with Freestyle or Mono backrest (K123975)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health and Human Services logo on the left and the FDA logo on the right. The FDA logo is a blue square with the letters "FDA" in white, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue.
March 4, 2022
Kinetic Innovative Seating System LLC Susan Farricielli President / Managing Partner 26 N. Main Street, Office Bldg Branford, Connecticut 06405
Re: K211919
Trade/Device Name: KISS Dynamic Solid Drop Seat, Model S1520 KISS Dynamic Back Support, Model B1620 Regulation Number: 21 CFR 890.3920 Regulation Name: Wheelchair Component Regulatory Class: Class I Product Code: KNN Dated: December 11, 2021 Received: December 15, 2021
Dear Susan Farricielli:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal
{1}------------------------------------------------
statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
for Heather Dean, PhD Assistant Director, Acute Injury Devices Team DHT5B: Division of Neuromodulation and Physical Medicine Devices OHT5: Office of Neurological and Physical Medicine Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known) K211919
#### Device Name
KISS Dynamic Solid Drop Seat, Model S1520 KISS Dynamic Back Support, Model B1620
#### Indications for Use (Describe)
The KISS Dynamic Solid Drop Seat and Back Support devices are wheelchair components intended for medical purposes that are generally sold as an integral part of a wheelchair but may also be sold separately as a replacement part.
The KISS Dynamic Solid Drop Seat and Back Support are intended to assist posture and positioning for a person seated in a wheelchair by way of providing a solid seating platform or back support with dynamic motion.
| Type of Use (Select one or both, as applicable) | |
|----------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------|
| <div style="display:flex; align-items:center;"><input type="checkbox"/> Prescription Use (Part 21 CFR 801 Subpart D)</div> | <div style="display:flex; align-items:center;"><input checked="" type="checkbox"/> Over-The-Counter Use (21 CFR 801 Subpart C)</div> |
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
Image /page/3/Picture/0 description: The image shows the logo for KISS, which stands for Kinetic Innovative Seating System, LLC. The logo features the word "Kiss" in a stylized font, with the "i" in "Kiss" being red. The rest of the letters are black. Below the logo is the full name of the company, "Kinetic Innovative Seating System, LLC".
Image /page/3/Picture/1 description: The image shows a diagram of a wheelchair with a red banner that reads "comfortable seating for wheelchairs". The wheelchair is drawn in a simple, technical style, with clean lines and minimal detail. The red banner is positioned horizontally across the image, partially obscuring the wheelchair's backrest.
# 510(k) SUMMARY
as required by 21CFR 807.92
# KISS DYNAMIC SEATING SYSTEM (bundled devices): KISS SOLID DROP SEAT KISS DYNAMIC BACK SUPPORT K211919
#### Owner Information: Kinetic Innovative Seating System, LLC 26 N. Main Street, office bldg. Branford, CT 06405
Phone: (203) 488-1758 Fax: (203) 643-8006 Email: info@kissforwheelchairs.com Contact person: Susan Farricielli
Date of revised Summary preparation: February 23, 2022
Name of the devices:
# Proprietary name(s) - KISS Dynamic Solid Drop Seat, Model S1520 KISS Dynamic Back Support, Model B1620
Common name(s) = drop seat / back support Classification name - wheelchair component (21 CFR 890.3920, Product Code KNN)
### Legally marketed device compared for a determination of substantial equivalence:
The KISS seat is substantially equivalent to K942312; product code KNN; device name, Alden Lineage Wheelchair Cushion. Both devices are wheelchair seating components, regulation number 890.3920.
The reference device for the KISS seat is K982989; product code IOR: regulation number 890.3850; device name, Quickie suspension wheelchair series model XTR with the Rock Shox® monoshock suspension by Sunrise Medical. K982989 has physical characteristics that are substantially equivalent to the KISS device. Both devices support a person seated upright in a wheelchair. Both devices have a provision for suspension under the seat.
{4}------------------------------------------------
The KISS back support is substantially equivalent to K923364; product code KNN; device name, Tilt Adjustable Back Recline Seating System by Labac Systems. Both devices are wheelchair seating components, regulation number 890.3920.
The reference device for the KISS back support is K123975; product code IOR; regulation number 890.3850; device name, Quickie and Zippie Series wheelchair with the Freestyle or Mono™ backrest by Sunrise Medical. K123975 has physical characteristics that are substantially equivalent to the KISS device. Both devices support a person seated upright in a wheelchair. Both devices have a provision for controlled movement of the back.
### Device description:
The KISS devices are wheelchair components intended for medical purposes generally sold as an integral part of a wheelchair but may also be sold separately as a replacement seat and back support. The KISS devices are intended to assist posture and positioning for a person seated in a wheelchair by way of providing a solid seat and back support with dynamic motion.
The KISS Seat consists of (1) a solid seating platform, (2) an adjustable seat frame, (3) pivot blocks, and (4) springs. The KISS seat replaces the standard cloth seat on a wheelchair frame. It attaches to the wheelchair with (5) four drop hooks and is locked in place with (6) securing hardware.
Image /page/4/Figure/5 description: This image shows a KISS Seat and its components. The components are labeled with numbers 1 through 6, and include the seating platform (1), seat frame (2), pivot blocks (3), springs (4), drop hooks (5), and securing hardware (6). The image provides a detailed view of the seat's construction and the arrangement of its parts.
The KISS Back Support consists of (1) a lumbar support with (2) mounting brackets and (3) an upper back support with a solid ventilated (4) backrest. The lumbar support and the upper back support are hinged together with (5) springs therebetween. (6) Mounting hardware connects the KISS back support to the wheelchair frame in place of the standard cloth backrest. (7) A removable upholstered cover encases the back support assembly.
{5}------------------------------------------------
Image /page/5/Figure/0 description: This image shows the KISS Back Support from a rear view. The image labels seven different parts of the back support, including the lumbar support (1), mounting brackets (2), upper back support (3), backrest (4), springs (5), mounting hardware (6), and upholstered cover (7). The image shows both a close up of the back support and how it looks attached to a wheelchair.
How the devices functions:
The KISS Seat assists upright seated posture by way of providing a solid seating platform with a dynamic seating interface that translates forces into motion. Springs under the seat respond to shifts in weight up and down and side to side. Movement is initiated at the hip and knee joints. The pelvis rotates and weight gets redistributed. KISS' solid seating platform eliminates the hammock effect of the standard cloth seat on a wheelchair. The springs provide suspension under the pelvis, where most of the user's weight is concentrated and absorb impact during wheelchair travel over bumps and thresholds.
Image /page/5/Figure/3 description: The image is a black and white drawing of a mechanical device. The device has a flat, rectangular base with several holes and springs visible. There are also several curved metal bars attached to the base, which appear to be part of the device's support structure. The drawing is detailed and technical in nature, suggesting it may be a blueprint or schematic.
The KISS seat responds to shifts in weight up and down and side to side.
{6}------------------------------------------------
The KISS Back Support assists upright seated posture by way of providing a solid back support with a provision for movement of the upper back. The device is mounted to the wheelchair frame at the height, depth, and angle adjusted to the individual user. The lumber support is fixed in place and stabilizes the user in the seat. The upper back support moves about a horizontal axis in response to rearward force, relative to the lumbar support. Springs therebetween provide resilience and assist the user back to an upright seated position.
Image /page/6/Figure/1 description: The image is a black and white technical drawing of a piece of equipment. The equipment has a flat, rectangular back with several circular holes in it. The equipment is attached to two parallel bars that are connected to vertical supports on either side.
KISS' upper back support moves in response to rearward force. Springs assist the user back to an upright seated position.
## Scientific concept for the KISS devices:
Investigations of sitting discomfort for individuals who sit for long periods of time have led to the development of ergonomic seating systems that enhance posture and comfort based on the premise that comfort is not achieved from a single, static position, but requires changes in posture through motion. The KISS devices are designed to translate forces generated by a wheelchair user's intentional or unintentional movement into motion. The intent is to allow, rather than block, the individual's specific movements. The devices are designed to absorb forces, which in turn initiates movement and disperses pressure in the wheelchair seat.
Significant physical and performance characteristics (Specifications):
The devices have a weight capacity of 250 LBS and fit manual wheelchairs 16" - 20" wide. The devices attach to tubular wheelchair frames 7/8" to 1-1/8" in diameter. The solid drop seat is designed to be used with a variety of wheelchair cushions. The back support is designed with a padded upholstered cover.
| Specifications | KISS seat, model S1520 | KISS back support, model B1620 |
|-----------------|------------------------|--------------------------------|
| Width | 16-1/4" — 20-1/4" | 16-1/4" – 20-1/4" |
| Height | 4-1/8" — 5-5/8" | 15-1/2" |
| Depth | 16" | 4-1/4" |
| Weight | 1.78 LBS | 8 LBS |
| Weight Capacity | 250 LBS | 250 LBS |
{7}------------------------------------------------
Image /page/7/Figure/0 description: The image shows a diagram of a KISS seat and back support with measurements. The KISS seat is 16 inches in height and 16-1/4 to 20-1/4 inches in width. The KISS back support is 15-1/2 inches in height and 4-1/4 inches in width, and the seat is 4-1/8 to 5-5/8 inches in height.
The KISS seat moves in response to shifts in weight up and down and side to side. Springs are positioned bilaterally under the pelvis, where most of the user's weight is concentrated. The springs provides up to 3/4" of suspension and up to 4° of rear displacement in the seat. Compression springs and low-friction plastic pivot blocks assist smooth dynamic motion. The drop hooks connect the KISS seat to the wheelchair frame. Two sets are included to position the seat height level with the seat rails on the wheelchair frame or with 1-1/2" of seat drop. Securing hardware locks the seating system in place. The seating platform is resin-infused recycled paper (Richlite®). The seat frame and drop hooks are made of aluminum with an anodized finish.
The KISS back support attaches to the upright canes (or push bars). The lumbar support is fixed in place and stabilizes the user in the seat. The upper back support flexes up to 30° with rearward force. Springs provide resilience and assist the user back to an upright seated position. The back support gets mounted to the wheelchair such that the horizontal pivot axis of the upper back support is ±7' from the top of the wheelchair seat rails. The mounting brackets adjust in width and are reversible for up to 4" of additional depth adjustment and up to 15° of overall angle adjustment. The upholstered cover fits over the back support assembly. The lumbar support, mounting brackets, and mounting hardware are anodized aluminum. The upper back support is powder-coated steel. The backrest is Richlite®. The upholstered cover is polyester. The padding is polyurethane foam encased in a layered lining comprised of polyester, fire barrier, and cotton fabric.
{8}------------------------------------------------
| KISS Dynamic Solid Drop Seat | | | |
|------------------------------|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------|
| PART | NAME | FUNCTION | MATERIAL |
| 1 | SEATING<br>PLATFORM | Provides solid postural support. For use with a<br>wheelchair cushion. | Richlite® (resin-infused<br>recycled paper) |
| 2 | SEAT<br>FRAME | Rigid frame supports the seating platform and<br>spring components. Adjusts in depth. | Aluminum with<br>anodized finish |
| 3 | PIVOT<br>BLOCKS | Connect the seating platform to the seat frame and<br>permits smooth dynamic movement of the seat. | Delrin® (low-friction<br>plastic) |
| 4 | SPRINGS | Spring assemblies connect to seat frame and<br>seating platform. Provides up to 3/4" of seat<br>suspension with up to 4° of rear displacement. | Compression springs,<br>plastic, rubber |
| 5 | DROP<br>HOOKS | Connects the KISS seat frame to the wheelchair<br>frame. Adjusts to wheelchairs 16" to 20" wide.<br>Positions seat height relative to the seat rails of the<br>wheelchair frame: level or with 1-1/2" of seat drop. | Aluminum with<br>anodized finish |
| 6 | SECURING<br>HARDWARE | Locks KISS seat assembly to the wheelchair frame<br>(supplied by third-party vendors). | AEL VERSAlock® or<br>Bodypoint Clickit®<br>(plastic & steel) |
# KISS Dynamic Back Support
| PART | NAME | FUNCTION | MATERIAL |
|------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------|
| 1 | LUMBAR SUPPORT | Provides lower back support. Stabilizes the user in the seat. | Aluminum with anodized finish |
| 2 | MOUNTING BRACKETS | Adjusts to the wheelchair width. Provides up to 4" of additional depth and up to 15° of overall angle adjustment. | Aluminum with anodized finish |
| 3 | UPPER BACK SUPPORT | Moves with rearward force. Flexes up to 30° rearward. | Steel with powder-coated finish |
| 4 | BACKREST | Attaches to the upper back support. Provides solid postural support. | Richlite® (resin-infused recycled paper) |
| 5 | SPRINGS | Provide resilience to the upper back support. Assists the user back to an upright position. | Spring steel |
| 6 | MOUNTING HARDWARE | Secures the back support to the wheelchair. Fits tubular frames 7/8" to 1-1/8" in diameter. | Aluminum with anodized finish |
| 7 | UPHOLSTERED COVER | Pads and protects the user from the solid surfaces and moving parts. Cover is removable and washable. Padded inserts are removable. | Polyester, Tek Fire Barrier, and cotton fabric with Polyurethane foam padding |
{9}------------------------------------------------
#### Intended use:
The KISS devices are wheelchair components intended for medical purposes that are generally sold as an integral part of a wheelchair but may also be sold separately as a replacement part. The KISS devices are intended to assist posture and positioning for a person seated in a wheelchair by way of providing a solid seating platform or back support with dynamic motion.
### Comparison of indication statement:
The predicate devices' product code is KNN, classification 890.3920, wheelchair component. The Jay Basic Back and the Jay Adjustable Solid Seat by Sunrise Medical are solid postural supports for a person seated in a wheelchair. These devices are intended for posture and positioning in a wheelchair and are 510(k) exempt.
The reference devices' product code is IOR, classification 890.3850, mechanical wheelchair. K982989 and K123975 are Sunrise Medical's Quickie and Zippie series wheelchairs with provisions for suspension in the seat and controlled movement of the back. These devices are intended for individuals limited to a sitting position.
The KISS devices are solid postural supports for a wheelchair with provisions for movement of the seat and back support. The devices are intended for posture and positioning for a person seated in a wheelchair. The differences are not critical to the intended therapeutic use because the KISS devices do not alter the safety and effectiveness of the device when used as labeled.
#### Comparison of technological characteristics of the KISS devices to the reference devices:
The K982989 suspension series wheelchair and the KISS seat are similar in technological characteristics. Both devices provide suspension for a person seated in a wheelchair. The reference device is a wheelchair with suspension located under the wheelchair seat that provides up to 2.5" of rear wheel displacement. The KISS device is a wheelchair seat with suspension that provides up to 3/4" of rear seat displacement.
The K123975 Quickie & Zippie series wheelchair and the KISS back support are similar in technological characteristics. Both devices have solid back supports that move with rearward force. The predicate device is a wheelchair with a back support system. The KISS device is a back support system for a wheelchair. The Ouickie Freestyle backrest system piyots about a horizontal axis at the middle of the backrest. The Quickie Mono™ backrest pivots about a horizontal axis at the base of the back. Elastomer springs on the Mono™ backrest assist the wheelchair user back to an upright seated position. The Quickie back support systems are modifications the Quickie series wheelchair. The KISS back support is a modification to a wheelchair because it replaces the standard cloth backrest on the wheelchair.
{10}------------------------------------------------
## Device Comparison Table:
| Description | KISS seat | Reference Device K982989 |
|-----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Indications for Use | For posture and positioning | To provide mobility to persons limited<br>to a sitting position |
| Prescription / over-the-<br>counter use | Prescription & Over-the-counter | Prescription & Over-the-counter |
| Size | Fits wheelchairs 16" – 20" | Wheelchair sizes 14" – 20" |
| Seat height | Level with wheelchair seat rails; with 1-1/2"<br>seat drop option | Level with wheelchair seat rails with<br>wheelchair frame adjustments |
| Design | Device consists of a seat frame and a solid<br>seating platform with suspension<br>therebetween. Seating system attaches to<br>wheelchair frame with drop hooks and<br>securing hardware. | Device is a suspension series<br>wheelchair with a standard cloth seat.<br>The Rock Shox® monoshock<br>suspension is located under the seat<br>and integrated with wheelchair<br>frame. |
| Suspension | Compression spring assemblies located<br>between the seat frame the solid seating<br>platform responds to shifts in weight up<br>and down and side to side. The device<br>provides up to .75" of suspension with up<br>to 4° of rear displacement in the seat. | The Rock Shox® assembly is mounted<br>under the wheelchair seat and<br>integrated with the wheelchair frame.<br>The system provides shock absorption<br>with up to 2.5" of rear wheel travel in<br>response to uneven terrain. |
| Attachment to<br>wheelchair | Suspension is integrated in seat assembly<br>that attaches to wheelchair frame with<br>drop hooks & securing hardware. | Suspension is integrated with<br>wheelchair frame. |
| Seat Cushion | For use with a wheelchair cushion | For use with a wheelchair cushion |
| Weight capacity | 250 lbs. | 250 lbs. |
| Description | KISS back support | Reference Device K123975 |
|----------------------------------|------------------------------------|----------------------------------------------------------------------|
| Indications for Use | For posture and<br>positioning | To provide mobility to persons limited to a sitting<br>position |
| Prescription/over-thecounter use | Prescription & Over-thecounter | Prescription & Over-the-counter |
| Size | Fits wheelchair sizes 16" –<br>20" | Wheelchair sizes:<br>Quickie IRIS: 14" – 22"<br>Quickie 7: 12" – 20" |
| Height of Back Support | Mid back | Quickie IRIS: Shoulder height<br>Quickie 7: Mid back |
{11}------------------------------------------------
| Design | Device consists of a lumbar<br>support and an upper back<br>support with springs there<br>between. The lumbar<br>support gets fixed to the<br>wheelchair and stabilizes<br>the user in the seat. | Quickie IRIS: Mono™ Backrest replaces the standard<br>back rest on the wheelchair frame and provides solid<br>postural support that moves with resilience.<br>Quickie 7: Freestyle Backrest System is integrated with<br>the wheelchair frame to provide solid mid-height back<br>support that moves. |
|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Movement | Upper back support moves<br>relative to lower lumbar<br>support about a transvers<br>horizontal axis. | Quickie IRIS: Full-length Mono™ Backrest (with<br>dynamic option) moves about a horizontal axis at the<br>base of the back support system.<br>Quickie 7: Freestyle Backrest System moves about a<br>horizontal axis at the middle of the backrest. |
| Dynamic component | Two spring steel<br>assemblies mounted<br>between lumbar support<br>and upper back support | Quickie IRIS: Two elastomer spring assemblies are<br>integrated in mounting bracket of the Mono™<br>Backrest.<br>Quickie 7: Freestyle Backrest System moves freely<br>without springs |
| Wheelchair attachment | Attaches to a standard<br>manual wheelchair frame | Mono™ Backrest attaches to Quickie IRIS wheelchair<br>with a modification to the frame.<br>Freestyle Backrest System is integrated with a<br>modified frame for the Quickie 7 wheelchair. |
| Weight capacity | 250 lbs | 250 lbs / 350 lbs (Heavy Duty) |
# Assessment of performance data - Non-clinical data:
The KISS devices passed ISO 16840-3 Wheelchair seating – Part 3: Determination of static, impact and repetitive load strengths for postural support devices.
The KISS devices were installed on a Quickie series wheelchair and tested according to RESNA WC-1, Sections 1, 5 & 7 for static stability, maneuverability, dimensions, and seating measurements. Wheelchair stability with the KISS seat was increased on the rearward incline with the wheels locked and decreased on the rearward (wheels unlocked), forward and lateral inclines. Wheelchair stability with the KISS back support was increased on rearward inclines and decreased on forward and lateral inclines. Maneuverability, dimensions, and measurements were not changed.
ISO 898-7 was applied to test the durability of the clamping system and mechanical fasteners to hold the KISS seat in place. Selected securing hardware intended to be used with the KISS device was tested and passed.
Loaded Deflection was tested to determine the most effective position for placement of the springs under the KISS seat. The results indicate that the springs should be positioned under the pelvis and not exceed one adjustment position (1") to either side of this position.
{12}------------------------------------------------
A customized bench test to determine The Influence of the KiSS dynamic seat on a Wheelchair Cushion's Force-Deflection relationship was conducted to address FDA concerns with prior submission K120940 regarding off-loading from the wheelchair cushion when used with the KISS seat. The results indicate that the user should lift an additional 0.4" to fully offload from the wheelchair cushion.
The KISS seat was tested for Wheelchair Compatibility on an assortment of wheelchairs. The purpose was to identify restrictions and measure clearances needed to install the KISS seat on a wheelchair frame. The KISS seat fit the standard folding manual wheelchairs and not the ultralight models because of the design of the rigid frame.
Lab test results for ISO 10993-10: Biological evaluation of medical devices - Part 10 indicate biocompatibility for cytotoxicity, skin irritation and sensitization for the KISS back support upholstered cover. The upholstered cover was tested for resistance to ignition according to ISO 16840-10. Test #1 passed; Test #2 failed due to the sample continuing to emit visible smoke for 30 seconds after removal of the heater cartridge. The standard currently only allows 20 seconds, therefore the specimen did not pass the criteria after the initial test was performed.
## Conclusion:
The performance report data indicate that the KISS devices installed on a wheelchair is as safe, as effective, and performs as well as the predicate and reference devices K982989 and K123975. The devices passed ISO and RESNA bench test standards. Clinical testing indicates the technology does not negatively affect interface pressure and has reduced peak interface pressures measured during propulsion. However, dynamic seating may reduce wheelchair stability, therefore, contraindications as noted in the proposed labeling must be observed.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.