Imboki Knee Instrument System

K181338 · Signature Orthopaedics Pty, Ltd. · JWH · Jan 17, 2019 · Orthopedic

Device Facts

Record IDK181338
Device NameImboki Knee Instrument System
ApplicantSignature Orthopaedics Pty, Ltd.
Product CodeJWH · Orthopedic
Decision DateJan 17, 2019
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3560
Device ClassClass 2

Intended Use

Signature Orthopaedics Imboki Knee Instrument System are accessory devices intended to be used to assist the implantation of Signature Orthopaedics' World Total Knee System and its cleared indications for use. The patient should be skeletally mature to receive a knee replacement. Patients should have adequate bone stock and size to support and accept the prosthesis. The patient's need for knee replacement should be due to one or more of the following conditions: - Non-inflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, or avascular necrosis. - Inflammatory degenerative joint disease including rheumatoid arthritis. - Functional deformity such as varus, valgus or flexion deformities. - Revision procedures where other treatments or devices have failed. - Fractures that are unmanageable using other techniques.

Device Story

Imboki Knee Instrument System comprises manual orthopaedic surgical instruments assisting implantation of World Total Knee System. Includes device-specific components (World Smart Card) and non-device specific instruments (trial instruments for femoral, tibial, patella components). World Smart Card acts as rectangular guide for femoral alignment and distal resection. Used in surgical settings by orthopaedic surgeons. Instruments facilitate precise positioning and resection during total knee arthroplasty. Benefits include standardized surgical workflow and accurate prosthesis placement.

Clinical Evidence

No clinical data required. Substantial equivalence supported by bench testing and validation/verification conducted on the previously cleared World Total Knee System (K180750).

Technological Characteristics

Manual surgical instruments. Materials: Acetal polymer (ASTM F1855) for World Smart Card; 630 stainless steel (ASTM A269) or 420 stainless steel (ASTM F899) for other instruments. Supplied non-sterile. No energy source or software.

Indications for Use

Indicated for skeletally mature patients requiring knee replacement due to non-inflammatory degenerative joint disease (osteoarthritis, traumatic arthritis, avascular necrosis), inflammatory degenerative joint disease (rheumatoid arthritis), functional deformity (varus, valgus, flexion), revision procedures, or unmanageable fractures. Requires adequate bone stock.

Regulatory Classification

Identification

A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image contains the logos of the Department of Health & Human Services and the Food and Drug Administration (FDA). The Department of Health & Human Services logo is on the left, and the FDA logo is on the right. The FDA logo includes the text "FDA U.S. FOOD & DRUG ADMINISTRATION" in blue font. January 17, 2019 Signature Orthopaedics Pty Ltd. Declan Brazil Managing Director 7 Sirius Road Lane Cove, NSW 2066, Australia Re: K181338 Trade/Device Name: Imboki Knee Instrument System Regulation Number: 21 CFR 888.3560 Regulation Name: Knee Joint Patellofemorotibial Polymer Semi-Constrained Cemented Prosthesis Regulatory Class: Class II Product Code: JWH Dated: October 19, 2018 Received: October 24, 2018 Dear Declan Brazil: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal {1}------------------------------------------------ statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/CombinationProducts/GuidanceRegulatoryInformation/ucm597488.html; good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803). please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Image /page/1/Figure/5 description: The image shows the name Peter G. Allen -S. The text 'Digitally signed by Peter G. Allen -S' is also present. The date '2019.01.17' and time '16:20:47 -05'00'' are also included in the image. FOR Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K181338 Device Name Imboki Knee Instrument System ### Indications for Use (Describe) Signature Orthopaedics Imboki Knee Instrument System are accessory devices intended to be used to assist the implantation of Signature Orthopaedics' World Total Knee System and its cleared indications for use. The patient should be skeletally mature to receive a knee replacement. Patients should have adequate bone stock and size to support and accept the prosthesis. The patient's need for knee replacement should be due to one or more of the following conditions: - · Non-inflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, or avascular necrosis. - · Inflammatory degenerative joint disease including rheumatoid arthritis. - · Functional deformity such as varus, valgus or flexion deformities. - · Revision procedures where other treatments or devices have failed. - · Fractures that are unmanageable using other techniques. | Type of Use (Select one or both, as applicable) | |--------------------------------------------------------------------------------------------------| | <span> <input checked="" type="checkbox"/> Prescription Use (Part 21 CFR 801 Subpart D) </span> | | <span> <input type="checkbox"/> Over-The-Counter Use (21 CFR 801 Subpart C) </span> | ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ #### 2 510(K) SUMMARY | Manufacturer: | Signature Orthopaedics Pty Ltd<br>7 Sirius Road<br>Lane Cove, NSW 2066<br>Australia | |-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------| | Device Trade<br>Name: | Imboki Knee Instrument System | | Common Name: | Orthopaedic Surgical Instrumentation | | Contact: | Dr. Declan Brazil<br>Managing Director of Signature Orthopaedics | | Prepared By: | Signature Orthopaedics Pty Ltd<br>7 Sirius Road<br>Lane Cove, NSW 2066<br>Australia<br>Phone: +61 (2) 9428 5181<br>Fax: +61 (2) 8456 6065 | | Date Prepared: | 18 May, 2018 | | Classification: | Class II per CFR 888.3560: Knee Joint Patellofemorotibial<br>Polymer/Metal/Polymer Semi-Constrained Cemented Prosthesis<br>prosthesis (JWH) | | Predicate Devices: | Primary Predicate<br>• World Total Knee System (K180750) | ### Device Description: The Imboki Knee Instrument System is a simplified instrument set containing accessory devices that are intended to assist in the implantation of Signature Orthopaedics' previously cleared World Total Knee System (K180750). The Imboki Knee Instrument System consists of manual orthopaedic surgical instruments which are either device-specific or non-device specific. The World Smart Card is a device-specific component which varies in geometry to match the specific dimensions of a particular sized World Knee component. It is a rectangular guide manufactured from acetal polymer as per ASTM F1855 which is assembled with the IM rod to assist with femoral alignment and distal resection. The Imboki Knee Instrument System also includes the same trial instruments as the World Knee previously cleared under 510(k) submission K180750 for the femoral, tibial and patella components. The non-device specific instruments are manufactured from 630 stainless steel as per ASTM A269 or 420 stainless steel as per ASTM F899. All instruments are supplied non-sterile. {4}------------------------------------------------ ## Indications for Use: Signature Orthopaedics Imboki Knee Instrument System are accessory devices intended to be used to assist the implantation of Signature Orthopaedics' World Total Knee System and its cleared indications for use. The patient should be skeletally mature to receive a knee replacement. Patients should have adequate bone stock and size to support and accept the prosthesis. The patient's need for knee replacement should be due to one or more of the following conditions: - . Non-inflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, or avascular necrosis. - Inflammatory degenerative joint disease including rheumatoid arthritis. - Functional deformity such as varus, valgus or flexion deformities. - Revision procedures where other treatments or devices have failed. - Fractures that are unmanageable using other techniques. ## Performance Testing: Clinical data is not required to support the safety and effectiveness of the Imboki Knee Instrument System. The Imboki Knee Instrument System is considered to be substantially equivalent to Signature Orthopaedics' World Total Knee System instruments (K180750). There are no new issues which have been raised relating to safety or effectiveness of the subject devices. Therefore, the Imboki Knee Instrument System falls within the scope of validation and verification conducted on Signature Orthopaedics' previously cleared World Total Knee System. ### Substantial Equivalence: The Imboki Knee Instrument System is considered to be substantially equivalent to Signature Orthopaedics' World Total Knee System instruments (K180750). The Imboki Knee Instrument System has the same materials, manufacturing route, principle of operation, sterilisation procedure, indications for use and body contact as the World Knee instruments.
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%