← Product Code FRO · K181197

# PHMB Foam Wound Dressing (K181197)

_Advanced Medical Solutions, Ltd. · FRO · Aug 3, 2018 · SU · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K181197

## Device Facts

- **Applicant:** Advanced Medical Solutions, Ltd.
- **Product Code:** FRO
- **Decision Date:** Aug 3, 2018
- **Decision:** SESE
- **Submission Type:** Traditional
- **Device Class:** Class U
- **Review Panel:** SU
- **Attributes:** Therapeutic

## Intended Use

PHMB Foam Wound Dressings are indicated for use in the management of post-surgical incisions, pressure sores, venous stasis ulcers, diabetic ulcers, donor sites, abrasions, lacerations, 1st and 2nd degree burns, dermatologic disorders, other wounds inflicted by trauma and, as a secondary dressing or cover dressing for packed wounds.

## Device Story

Polyurethane foam dressing impregnated with Polyhexamethylene Biguanide (PHMB); microporous hydrophilic structure absorbs wound exudate; maintains moist healing environment; PHMB acts as antimicrobial agent preventing bacterial colonization/proliferation within dressing for up to 7 days; provides barrier to bacterial penetration; available in non-adhesive and adhesive versions; supplied sterile; single-use; applied by healthcare professionals to manage various wound types; benefits patient by reducing bacterial load and protecting wound bed.

## Clinical Evidence

Bench testing only. In-vitro performance data demonstrated antimicrobial efficacy against 3 gram-positive bacteria (MRSA, MRSE, VRE), 3 gram-negative bacteria (E. coli, K. pneumoniae, P. aeruginosa), and 2 yeast species (C. albicans, R. mucilaginosa). Fluid handling and peel adhesion testing performed. Biocompatibility testing conducted per ISO 10993-1 for prolonged contact (<30 days).

## Technological Characteristics

Multi-layer polyurethane foam pad containing 0.8-1.1% w/w PHMB. Semi-occlusive film backing allows gas/moisture exchange and acts as bacterial barrier. Wound contact layer prevents adherence. Sterile, single-use.

## Predicate Devices

- PHMB Foam Wound Dressing ([K163062](/device/K163062.md))

## Reference Devices

- Kendall™ AMD Antimicrobial Wound Dressing ([K082296](/device/K082296.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.

August 3, 2018

Advanced Medical Solutions Ltd. Rose Guang QA/RA Director Premier Park, 33 Road One, Winsford Industrial Estate Winsford, CW7 3RT Gb

Re: K181197

Trade/Device Name: PHMB Foam Wound Dressing Regulatory Class: Unclassified Product Code: FRO Dated: May 2, 2018 Received: May 7, 2018

Dear Rose Guang:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 

{1}------------------------------------------------

801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/CombinationProducts/GuidanceRegulatoryInformation/ucm597488.htm); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4. Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.

For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely.

# David Krause -S

for Binita S. Ashar, M.D., M.B.A., F.A.C.S. Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

## Indications for Use

510(k) Number (if known) K181197

Device Name PHMB Foam Wound Dressing

#### Indications for Use (Describe)

PHMB Foam Wound Dressings are indicated for use in the management of post-surgical incisions, pressure sores, venous stasis ulcers, diabetic ulcers, donor sites, abrasions, 1st and 2nd degree burns, dermatologic disorders, other wounds inflicted by trauma and, as a secondary dressing for packed wounds.

Type of Use (Select one or both, as applicable):

| <span> <b>☑</b> Prescription Use (Part 21 CFR 801 Subpart D)       </span> |
|----------------------------------------------------------------------------|
| <span>         ☐ Over-The-Counter Use (21 CFR 801 Subpart C)       </span> |

#### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image contains the logo for Advanced Medical Solutions Ltd. The logo features a stylized blue "A" with a swoosh extending from the top right. Below the logo, the text "Advanced Medical Solutions Ltd" is written in a blue sans-serif font.

Advanced Medical Solutions Limited Premier Park, 33 Road One Winsford Industrial Estate Cheshire. CW7 3RT. UK

### 510(k) Summary Statement

| Submitted by:        | Advanced Medical Solutions Ltd<br>Premier Park<br>33 Road One<br>Winsford Industrial Estate<br>Winsford<br>Cheshire<br>CW7 3RT<br>Tel: +44 1606 863500<br>Fax: +44 1606 863600 |
|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Person:      | Rose Guang                                                                                                                                                                     |
| Date of Summary:     | 03 August 2018                                                                                                                                                                 |
| Trade Name:          | PHMB Foam Wound Dressing                                                                                                                                                       |
| Common Name:         | PHMB Wound Dressing                                                                                                                                                            |
| Classification Name: | Dressing, Wound, Drug                                                                                                                                                          |
| Classification:      | Unclassified (Pre-amendment)                                                                                                                                                   |
| Classification Code: | Product code: FRO                                                                                                                                                              |
| Predicate Device(s): | PHMB Foam Wound Dressing (K163062)                                                                                                                                             |
| Reference Device(s): | Kendall™ AMD Antimicrobial Wound Dressing (K082296)                                                                                                                            |

Image /page/3/Picture/4 description: The image shows two certification logos. The first logo on the left is the BSI (British Standards Institution) logo, which features the letters 'bsi' above a heart shape, all enclosed in a circle. The second logo on the right is the UKAS (United Kingdom Accreditation Service) Management Systems logo, which includes a crown above a checkmark, with the text 'UKAS MANAGEMENT SYSTEMS' below it, and the number '003' at the bottom. Below the logos, the text 'Certificate No. MD78010' is printed.

{4}------------------------------------------------

K181197

Image /page/4/Picture/1 description: The image shows the logo for Advanced Medical Solutions Ltd. The logo features a blue stylized letter "A" with a swoosh extending from the top right. The text "Advanced Medical Solutions Ltd" is written in blue below the logo.

Advanced Medical Solutions Limited Premier Park, 33 Road One Winsford Industrial Estate Cheshire. CW7 3RT. UK

| Device Description:      | The subject device, PHMB Foam Wound Dressing, is a polyurethane             foam impregnated with Polyhexamethylene Biguanide (PHMB), an             agent that protects the dressing from bacterial penetration and             colonization. <p>                 The foam in the dressings has a microporous hydrophilic foam structure                 that absorbs wound exudate and maintains a moist wound healing                 environment.             </p> <p>                 Based on <i>in vitro</i> performance data, the PHMB Foam Wound Dressing                 provides a barrier to bacterial penetration through the dressing and the                 PHMB prevents colonization and proliferation of bacteria within the                 dressing for up to 7 days.             </p> <p>                 PHMB Foam dressing, when tested <i>in-vitro</i> has demonstrated to be                 effective against the following three gram positive bacteria (MRSA,                 MRSE, VRE), three gram negative bacteria (<i>Escherichia coli, Klebsiella                 pneumoniae, Pseudomonas aeruginosa</i>) and two yeast (<i>Candida                 albicans, Rhodotorula mucilaginosa</i>) challenge organisms within the                 dressing.             </p> <p>                 The device is available in Non-border (non-adhesive) and Border                 (adhesive) versions.             </p> <p>                 The dressing is supplied sterile in a range of sizes between 4 in<sup>2</sup> to 64                 in<sup>2</sup>.             </p> |
|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Indication for Use:      | PHMB Foam Wound Dressings are indicated for use in the management             of post-surgical incisions, pressure sores, venous stasis ulcers, diabetic             ulcers, donor sites, abrasions, lacerations, 1st and 2nd degree burns,             dermatologic disorders, other wounds inflicted by trauma and, as a             secondary dressing or cover dressing for packed wounds.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
| Substantial Equivalence: | PHMB Foam Wound Dressing has substantially equivalent intended use             and labeling, identical design, materials, and performance             characteristics to the predicate device PHMB Foam Wound Dressing             (K163062).                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               |

Image /page/4/Picture/4 description: The image shows two logos side-by-side. The logo on the left is a circle containing a heart shape with the letters "bsi." above it. The logo on the right has a crown above a check mark with the words "UKAS MANAGEMENT SYSTEMS" below it, and the number "003" at the bottom. The text "Certificate No. MD78010" is located below the two logos.

{5}------------------------------------------------

K181197

Image /page/5/Picture/1 description: The image shows the logo for Advanced Medical Solutions Ltd. The logo features a stylized blue letter "A" with a swoosh extending from the top right. The text "Advanced Medical Solutions Ltd" is written in blue below the logo.

Advanced Medical Solutions Limited Premier Park, 33 Road One Winsford Industrial Estate Cheshire. CW7 3RT. UK

| Technological characteristics: | PHMB Foam Wound Dressing is a multi-layer one piece dressing design             incorporating an absorbent polyurethane foam pad containing 0.8-1.1             %w/w PHMB which is efficacious against three gram negative bacteria,             three gram positive bacteria, and two yeast microorganisms within the             dressing. The dressing is semi-occlusive allowing the exchange of gases             such as oxygen and moisture, and has a film that provides a barrier to             bacterial penetration through the dressing. The wound contact side of             the dressing protects the wound bed from adhering to the dressing.             PHMB Foam Wound Dressing is identical to the predicate device listed             when compared to the technological characteristics such as design,             materials, chemical composition, and manufacture and are supplied             sterile for single use. |
|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Performance Testing Summary:   | Performance data submitted in support of this 510k included in-vitro             and animal testing.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
|                                | Performance testing included total fluid handling and peel adhesion             (adhesive version only). In addition broad spectrum activity was             demonstrated to be effective against the following three gram positive             bacteria, three gram negative bacteria and two yeast challenge             organisms within the dressing:             Methicillin-Resistant S. aureus (MRSA)             Methicillin Resistant S. epidermidis (MRSE)             Vancomycin-Resistant E. faecalis (VRE)             Pseudomonas aeruginosa             Escherichia coli             Klebsiella pneumoniae             Candida albicans             Rhodotorula mucilaginosa                                                                                                                                                                                                                                                      |
|                                | Biological evaluation for prolonged contact (<30 days), conducted in             accordance with "Use of International Standard ISO 10993-1, Biological             Evaluation of Medical Devices Part 1: Evaluation and Testing within a             Risk Management process" demonstrates that PHMB Foam Wound             Dressings meet the requirements of BS EN ISO 10993-1 (Biological             Evaluation of Medical Devices) and are safe.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
| Conclusion:                    | Based on the information provided within this 510(k) submission,             Advanced Medical Solutions Ltd. concludes that the proposed PHMB             Foam Wound Dressing is substantially equivalent to the predicate             device listed and does not raise different questions of safety or             effectiveness.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |

Image /page/5/Picture/4 description: The image shows two certification logos. The logo on the left is the BSI (British Standards Institution) logo, which features the letters "bsi" above a heart shape, all enclosed in a circle. The logo on the right is the UKAS (United Kingdom Accreditation Service) Management Systems logo, which includes a crown above a check mark and the words "UKAS MANAGEMENT SYSTEMS" above the number "003". Below the logos, the text "Certificate No. MD78010" is printed.

---

**Source:** [https://fda.innolitics.com/device/K181197](https://fda.innolitics.com/device/K181197)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
