World Knee System
K180750 · Signature Orthopaedics Pty, Ltd. · JWH · Apr 20, 2018 · Orthopedic
Device Facts
| Record ID | K180750 |
| Device Name | World Knee System |
| Applicant | Signature Orthopaedics Pty, Ltd. |
| Product Code | JWH · Orthopedic |
| Decision Date | Apr 20, 2018 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 888.3560 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The patient should be skeletally mature to receive a knee replacement. Patients should have adequate bone stock and size to support and accept the prosthesis. The patient's need for knee replacement should be due to one or more of the following conditions: - Non-inflammatory degenerative joint disease including osteoarthritis, or avascular necrosis. - Inflammatory degenerative joint disease including rheumatoid arthritis. - Functional deformity such as varus, valgus or flexion deformities. - Revision procedures where other treatments or devices have failed. - Fractures that are unmanageable using other techniques. The World Knee replacement system is indicated for cemented fixation with bone cement (PMMA) only.
Device Story
Modular total knee prosthesis; includes femoral component, meniscal insert, patella, and tibial baseplate. Used in orthopedic surgery for knee joint replacement. Components implanted by surgeons in clinical settings. Femoral and tibial components made of cobalt chromium alloy; meniscal inserts and patella made of UHMWPE. Designed for cemented fixation using PMMA bone cement. Provides mechanical replacement of knee joint surfaces to restore function and alleviate pain associated with degenerative joint disease, deformity, or trauma. System offers posterior stabilized or cruciate retaining variants.
Clinical Evidence
Bench testing only. Engineering evaluations were conducted to verify that the performance of the World Knee system is equal or better than the predicate device.
Technological Characteristics
Modular knee prosthesis. Materials: Cast cobalt chromium alloy (femoral/tibial), wrought cobalt chromium alloy (femoral peg), UHMWPE (meniscal insert/patella). Fixation: Cemented (PMMA). Variants: Posterior stabilized or cruciate retaining. Design: Same geometry and fundamental design as predicate. Sterilization: Same as predicate.
Indications for Use
Indicated for skeletally mature patients requiring knee replacement due to non-inflammatory degenerative joint disease (osteoarthritis, avascular necrosis), inflammatory degenerative joint disease (rheumatoid arthritis), functional deformity (varus, valgus, flexion), revision procedures, or unmanageable fractures. Requires adequate bone stock. Cemented fixation only.
Regulatory Classification
Identification
A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).
Predicate Devices
- Signature Orthopaedics Genius Total Knee System (K170613)
Related Devices
- K170613 — Genius Total Knee System · Signature Orthopaedics Pty, Ltd. · Jul 17, 2017
- K180446 — b-ONE Total Knee System · B-One Ortho, Corp. · Oct 12, 2018
- K191084 — The Optimotion Blue Total Knee System · Optimotion Implants, LLC · Apr 7, 2020
- K181530 — World Total Knee System · Signature Orthopaedics Pty, Ltd. · Oct 24, 2018
- K253239 — Active-V Total Knee System; World Total Knee System · Signature Orthopaedics Pty, Ltd. · Dec 23, 2025
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which consists of the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text.
Signature Orthopaedics Pty Ltd. Declan Brazil Managing Director 7 Sirius Road Lane Cove, NSW 2066 Australia
April 20, 2018
Re: K180750
Trade/Device Name: World Knee System Regulation Number: 21 CFR 888.3560 Regulation Name: Knee Joint Patellofemorotibial Polymer Semi-Constrained Cemented Prosthesis Regulatory Class: Class II Product Code: JWH Dated: March 15, 2018 Received: March 22, 2018
Dear Declan Brazil:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good
{1}------------------------------------------------
manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely.
# Katherine D. Kavlock -S
for Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K180750
Device Name World Knee System
#### Indications for Use (Describe)
The patient should be skeletally mature to receive a knee replacement. Patients should have adequate bone stock and size to support and accept the prosthesis.
- The patient's need for knee replacement should be due to one or more of the following conditions:
- · Non-inflammatory degenerative joint disease including osteoarthritis, or avascular necrosis.
- · Inflammatory degenerative joint disease including rheumatoid arthritis.
- · Functional deformity such as varus, valgus or flexion deformities.
- · Revision procedures where other treatments or devices have failed.
- · Fractures that are unmanageable using other techniques.
The World Knee replacement system is indicated for cemented fixation with bone cement (PMMA) only.
| Type of Use (Select one or both, as applicable) |
|-------------------------------------------------|
|-------------------------------------------------|
X Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
# 510(K) SUMMARY
| Manufacturer: | Signature Orthopaedics Pty Ltd<br>7 Sirius Road<br>Lane Cove, NSW 2066<br>Australia |
|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------|
| Device Trade Name: | World Knee System |
| Common Name: | Total Knee Prosthesis |
| Contact: | Dr. Declan Brazil |
| | Managing Director of Signature Orthopaedics |
| Prepared By: | Signature Orthopaedics Pty Ltd<br>7 Sirius Road<br>Lane Cove, NSW 2066<br>Australia<br>Phone: +61 (2) 9428 5181<br>Fax: +61 (2) 8456 6065 |
| Date Prepared: | January 12th, 2018 |
| Classification: | Knee joint patellofemorotibial polymer/metal/polymer semi-<br>constrained cemented prosthesis (JWH, 21CFR 888.3560) |
| Predicate Devices: | Substantial equivalence to the following device is claimed: |
| | ● Signature Orthopaedics Genius Total Knee System<br>(K170613) |
# Device Description:
The World Knee system is a modular knee system consisting of a femoral component, meniscal insert, a patella and a tibial baseplate. The femoral component and tibial baseplate components are manufactured from cast cobalt chromium alloy and are intended for use with bone cement. The modular femoral peg is manufactured from wrought cobalt chromium alloy. The femoral component and meniscal inserts are available as posterior stabilised or cruciate retaining variants. Cruciate retaining meniscal inserts are available as standard or ultracongruent designs. All variants of the meniscal insert and patella are manufactured from UHMWPE.
#### Indications for Use:
The patient should be skeletally mature to receive a knee replacement. Patients should have adequate bone stock and size to support and accept the prosthesis.
The patient's need for knee replacement should be due to one or more of the following
{4}------------------------------------------------
conditions:
- Non-inflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, or avascular necrosis.
- . Inflammatory degenerative joint disease including rheumatoid arthritis.
- . Functional deformity such as varus, valgus or flexion deformities.
- . Revision procedures where other treatments or devices have failed.
- Fractures that are unmanageable using other techniques. ●
The World Knee replacement system is indicated for cemented fixation with bone cement (PMMA) only.
# Performance Testing:
Engineering evaluations were conducted to verify that the performance of the World Knee system is is equal or better than the predicate device and therefore adequate for anticipated in-vivo use.
# Substantial Equivalence:
The World Knee System has the same intended use, indications for use, materials and similar design as the Signature Orthopaedics Genius Knee System (K170613). The subject devices are expected to perform adequately during clinical use.
# Comparison of technological characteristics
The following technological similarities exist between the subject and predicate devices:
- . the World Knee incorporates the same materials as the Genius Knee
- the World Knee has the same manufacturing process as the Genius Knee
- . the World Knee has the same geometry and fundamental design as the Genius Knee
- . the World Knee has the same body contact as the Genius Knee
- the World Knee has the same sterilization process as the Genius Knee
The following technological differences exist between the subject and predicate devices:
- . there are minor design differences in the femoral components, and meniscal insert component
- an additional 2 intermediate sizes have been added