PRAMA White Implant Systems
Device Facts
| Record ID | K180365 |
|---|---|
| Device Name | PRAMA White Implant Systems |
| Applicant | Sweden & Martina S.P.A. |
| Product Code | DZE · Dental |
| Decision Date | Jul 8, 2019 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
PRAMA White Implant Systems are intended for both one- and two-stage surgical procedures. PRAMA White Implant Systems, endosseous implant and abutments, are intended for immediate placement and function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function. PRAMA White Implant Systems are intended to be used in fully edentulous or partially edentulous maxillary and/or mandibular arches.
Device Story
PRAMA White Implant Systems consist of endosseous dental implants and abutments; designed for surgical placement into maxillary or mandibular bone; used to restore chewing function in edentulous or partially edentulous patients. Implants support prosthetic restorations; utilized by dental clinicians in clinical settings. Device provides structural foundation for tooth replacement; success dependent on achieving primary stability during surgical procedure. Benefits include restoration of oral function and aesthetics.
Clinical Evidence
bench testing only
Technological Characteristics
Endosseous dental implant system; includes implants and abutments; intended for one- or two-stage surgical procedures; supports single or multiple tooth applications.
Indications for Use
Indicated for patients requiring dental restoration in fully or partially edentulous maxillary or mandibular arches. Used for single or multiple tooth replacement via one- or two-stage surgical procedures, provided good primary stability and appropriate occlusal loading are achieved.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.