← Product Code [DQK](/productcode/DQK) · K173837

# RHYTHMIA HDx Mapping System (with software Version 2.0) (K173837)

_Boston Scientific Corporation · DQK · Jul 25, 2018 · Cardiovascular · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K173837

## Device Facts

- **Applicant:** Boston Scientific Corporation
- **Product Code:** [DQK](/productcode/DQK.md)
- **Decision Date:** Jul 25, 2018
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 870.1425
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular

## Indications for Use

The RHYTHMIA HDx™ Mapping System (with software Version 2.0) and accessories are indicated for catheter-based atrial and ventricular mapping. The mapping system allows real-time visualization of intracardiac catheters as well as display of cardiac maps in a number of different formats. The acquired patient signals, including body surface ECG and intracardiac electrograms, may also be recorded and displayed on the system's display screen.

## Device Story

System provides real-time 3D anatomical and electroanatomical cardiac maps; utilizes magnetic and impedance localization technology to track intracardiac catheters; acquires and displays body surface ECG and intracardiac electrograms. Used in electrophysiology labs by trained physicians; serves as capital equipment for mapping and data storage. Software Version 2.0 introduces DirectSense™ for local impedance display to assist catheter positioning, enhanced CT/MRI import, and improved mapping workflows. System processes inputs via Signal Station conduit to workstation; output displayed on monitors for physician guidance during cardiac procedures. Benefits include improved visualization and procedural navigation for cardiac mapping.

## Clinical Evidence

Bench performance testing confirmed 3D mapping accuracy and visualization of magnetic/impedance tracked catheters. Software verification and validation conducted under 'major' level of concern. Pre-clinical animal study performed per 21 CFR § 58 GLP regulations demonstrated no new safety questions.

## Technological Characteristics

Reusable capital equipment; magnetic and impedance-based catheter tracking; signal processing for ECG and intracardiac electrograms; supports multi-monitor display; software-based enhancements for impedance sensing and imaging data import.

## Regulatory Identification

A programmable diagnostic computer is a device that can be programmed to compute various physiologic or blood flow parameters based on the output from one or more electrodes, transducers, or measuring devices; this device includes any associated commercially supplied programs.

## Predicate Devices

- RHYTHMIA HDx™ Mapping System ([K162793](/device/K162793.md))
- CARTO® 3 EP Navigation System version 4.2 ([K133916](/device/K133916.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.

July 25, 2018

Boston Scientific Corporation Gregory Neal Senior Regulatory Affairs Specialist 125 Cambridgepark Drive Cambridge, Massachusetts 02140

## Re: K173837

Trade/Device Name: RHYTHMIA HDx™ Mapping System (with software Version 2.0) Regulation Number: 21 CFR 870.1425 Regulation Name: Programmable Diagnostic Computer Regulatory Class: Class II Product Code: DQK Dated: June 21, 2018 Received: June 25, 2018

# Dear Gregory Neal:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{1}------------------------------------------------

(1-800-638-2041 or 301-796-7100).

K173837

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.

For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website

Sincerely,

(http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone

Kenneth J. Cavanaugh -S

for

Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

# Indications for Use

510(k) Number (if known) K173837

Device Name

RHYTHMIA HDx™ Mapping System (with software Version 2.0)

### Indications for Use (Describe)

The RHYTHMIA HDx™ Mapping System (with software Version 2.0) and accessories are indicated for catheter-based atrial and ventricular mapping. The mapping system allows real-time visualization of intracardiac catheters as well as display of cardiac maps in a number of different formats. The acquired patient signals, including body surface ECG and intracardiac electrograms, may also be recorded and displayed on the system's display screen.

Type of Use (Select one or both, as applicable)

| <span style="unicode-bidi:embed; text-align:left;">☑ Prescription Use (Part 21 CFR 801 Subpart D)</span> |
|----------------------------------------------------------------------------------------------------------|
| <span>☐ Over-The-Counter Use (21 CFR 801 Subpart C)</span>                                               |

### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

## 510(K) SUMMARY 510(K) SUMMARY COMPLYING WITH 21 CFR 807.92

#### I. SUBMITTER

Boston Scientific Corporation 125 Cambridgepark Drive, Suite 600 Cambridge, MA 02140

Phone: 617-218-3813 Fax: 617-218-3850

Contact Person: Gregory Neal Date Prepared: December 18, 2017

#### II. DEVICE

Name of Device: RHYTHMIA HDx™ Mapping System (with software Version 2.0) Common or Usual Name: Cardiac Mapping System Classification Name: Programmable diagnostic computer (21 CFR 870.1425) Regulatory Class: Class II Product Code: DQK

#### III. PREDICATE DEVICES

Predicate: RHYTHMIA HDx™ Mapping System Boston Scientific Corporation (K162793, S.E. 03/10/2017) Predicate: CARTO® 3 EP Navigation System version 4.2, Biosense Webster, Inc. (K133916, S.E. 07/01/2014)

#### IV. DEVICE DESCRIPTION

The RHYTHMIA HDx™ Mapping System is a catheter-based atrial and ventricular mapping system designed to display 3D anatomical and electroanatomical maps of the human heart in real-time. The mapping system is intended to be used during electrophysiology procedures for cardiac mapping and storage of cardiac electrophysiological data. In addition, based on user-defined criteria, the system is able to acquire data over multiple cardiac beats. It is capable of real-time display through construction of maps using catheter magnetic and impedance localization technology and data from intracardiac and surface electrograms.

The Signal Station and related accessories provide data connection pathways for external input/output devices (e.g. catheters and recording systems) and serve as the data conduit to the system Workstation computer and software.

The subject device is reusable capital equipment that is intended to be used in an electrophysiology laboratory by physicians fully trained in cardiac electrophysiology.

{4}------------------------------------------------

#### V. INDICATIONS FOR USE

The RHYTHMIA HDxTM Mapping System (with software Version 2.0) and accessories are indicated for catheter-based atrial and ventricular mapping system allows realtime visualization of intracardiac catheters as well as display of cardiac maps in a number of different formats. The acquired patient signals, including body surface ECG and intracardiac electrograms, may also be recorded and displayed on the system's display screen.

### VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICE

Substantial equivalence of the RHYTHMIA HDx™ Mapping System with software Version 2.0 was established in terms of design features, performance testing, and indications for use as compared to the predicates RHYTHMIA HDx™ Mapping System and CARTO® 3 EP Navigation System. The subject device system has a similar design to the primary predicate device to include the same primary system components, operating principle, catheter tracking methods, and same intended use while incorporating the same feature functionality as the secondary predicate feature.

The technological differences between the subject device and the predicate RHYTHMIA HDx™ Mapping System include the following software enhancements:

- DirectSense™ feature provides real-time display of local impedance which . complements other diagnostic measures for the purpose of determining catheter location within the heart chamber.
- Enhanced CT and MRI capabilities, which allow import of pre-segmented file types. ●
- Improved initial map setup through enhanced mapping workflow. ●
- Support for multiple monitor displays. ●
- . Minor bug fixes.

#### VII. PERFORMANCE DATA

Testing was performed to verify functional performance, safety, and to support substantial equivalence determination. The subject RHYTHMIA HDx Mapping System software Version 2.0 passed all tests in accordance with appropriate test acceptance criteria and standards. No new questions of safety and effectiveness were raised.

## Software Verification and Validation

Software verification and validation testing was conducted based on 'major' level of concern in accordance with FDA Guidance for Industry and FDA Staff: Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices, issued May 11, 2005.

{5}------------------------------------------------

## Bench Performance Testing

- Mapping and Visualization - Confirmed that incorporation of the new software features does not negatively impact the ability to use the subject mapping system to: (1) accurately create 3D maps of the cardiac chambers of the heart; and (2) support visualization of magnetic and impedance tracked catheters.
- Software Performance Confirmed that the new software features meet the functional ● requirements.
- System Level Performance - Confirmed system level functionality under expected and worst case use conditions.

## Animal Study

A pre-clinical animal study conducted with 21 CFR § 58 GLP regulations was performed and demonstrated that the subject device software does not present new questions of safety associated with its use.

#### VIII. CONCLUSIONS

The software verification and validation, bench performance testing and animal study demonstrated that the RHYTHMIA HDx™ Mapping System software Version 2.0 performs as intended. This data supports that the subject device is substantially equivalent to identified predicate devices.

---

**Source:** [https://fda.innolitics.com/device/K173837](https://fda.innolitics.com/device/K173837)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
