IcePearl 2.1 CX L, IceForce 2.1 CX L

K162599 · Galil Medical , Ltd. · GEH · Oct 11, 2016 · General, Plastic Surgery

Device Facts

Record IDK162599
Device NameIcePearl 2.1 CX L, IceForce 2.1 CX L
ApplicantGalil Medical , Ltd.
Product CodeGEH · General, Plastic Surgery
Decision DateOct 11, 2016
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 878.4350
Device ClassClass 2
AttributesTherapeutic

Indications for Use

Galil Medical's IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are intended for cryoablative destruction of tissue during surgical procedures. The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, proctology, and urology. The systems are designed to destroy tissue by the application of extreme cold temperatures including prostate and kidney tissue, liver metastases, tumors, skin lesions, and warts.

Device Story

Sterile, single-use, disposable 2.1 mm cryoablation needles; used with Visual-ICE Cryoablation System. Needles convert high-pressure gas into extreme cold for tissue destruction or warm gas for thawing. Features sharp cutting tip, color-coded handle, gas tube, and connector; 90° angled handle configuration. Designed with 55 mm longer shaft than predicate to treat deep-seated tumors in patients with larger body habitus while maintaining CT gantry clearance. Operated by physicians in surgical settings. Output is controlled iceball formation for targeted tissue ablation. Benefits include precise destruction of malignant/benign tissue and palliative intervention.

Clinical Evidence

Bench testing only. Performance testing included freezing and in vivo performance evaluations conducted according to international standards and in-house protocols. Results confirmed that the needles meet defined specifications and do not raise new safety or effectiveness issues compared to the predicate.

Technological Characteristics

Disposable 2.1 mm cryoablation needles; 55 mm longer shaft than predicate. Gas-based (Joule-Thomson effect) freezing/thawing technology. Sterile, single-use. Compatible with Visual-ICE Cryoablation System. No changes to system software.

Indications for Use

Indicated for cryoablative destruction of tissue in urology (prostate cancer, BPH), oncology (malignant/benign tumors, palliative), dermatology (skin cancers, warts, lesions, angiomas, etc.), gynecology (malignant neoplasia, benign dysplasia), general surgery (rectal tumors, hemorrhoids, anal fissures, pilonidal cysts, breast fibroadenoma), ENT (oral tumors, leukoplakia), thoracic surgery (excluding cardiac), and proctology (anal/rectal growths).

Regulatory Classification

Identification

(1) Cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories. A cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories is a device intended to destroy tissue during surgical procedures by applying extreme cold. (2) Cryosurgical unit with a nitrous oxide cooled cryoprobe and accessories. A cryosurgical unit with a nitrous oxide cooled cryoprobe and accessories is a device intended to destroy tissue during surgical procedures, including urological applications, by applying extreme cold. (3) Cryosurgical unit with a carbon dioxide cooled cryoprobe or a carbon dioxide dry ice applicator and accessories. A cryosurgical unit with a carbon dioxide cooled cryoprobe or a carbon dioxide dry ice applicator and accessories is a device intended to destroy tissue during surgical procedures by applying extreme cold. The device is intended to treat disease conditions such as tumors, skin cancers, acne scars, or hemangiomas (benign tumors consisting of newly formed blood vessels) and various benign or malignant gynecological conditions affecting vulvar, vaginal, or cervical tissue. The device is not intended for urological applications.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized image of a human figure with three faces in profile, stacked on top of each other. The figure is positioned to the right of the text, which reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement around the figure. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 October 11, 2016 Galil Medical Ltd. Ms. Lynne Davies Sr. Manager, Regulatory Affairs 4364 Round Lake Road Arden Hills, Minnesota 55112 Re: K162599 Trade/Device Name: IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles Regulation Number: 21 CFR 878.4350 Regulation Name: Cryosurgical unit and accessories Regulatory Class: Class II Product Code: GEH Dated: September 15, 2016 Received: September 19, 2016 Dear Ms. Davies: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {2}------------------------------------------------ If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # Jennifer R. Stevenson -A For Binita S. Ashar, M.D., M.B.A., F.A.C.S. Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ # Indications for Use 510(k) Number (if known) K162599 Device Name IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles Indications for Use (Describe) Galil Medical's IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are intended for cryoablative destruction of tissue during surgical procedures. The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, and urology. The systems are designed to destroy tissue by the application of extreme cold temperatures including prostate and kidney tissue, liver metastases, tumors, skin lesions, and warts. The Galil Medical IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles have the following specific indications: - · Urology (ablation of prostate tissue in cases of prostate cancer and Benign Prostate Hyperplasia "BPH") - · Oncology (ablation of cancerous or malignant tissue and benign tumors, and palliative intervention) - · Dermatology (ablation or freezing of skin cancers and other cutaneous disorders. Destruction of warts or lesions, angiomas, sebaceous hyperplasia, basal cell tumors of the eyelid or canthus area, ulcerated basal cell tumors, dermatofibromas small hemanglomas, mucocele cysts, multiple warts, actinic and seborrheic keratoses, cavernous hemanglomas, perianal condylomata, and palliation of tumors of the skin.) - · Gynecology (ablation of malignant neoplasia or benign dysplasia of the female genitalia) · General surgery (palliation of tumors of the rectum, hemorrhoids, anal fissures, pilonidal cysts, and recurrent cancerous lesions, ablation of breast fibroadenoma) - · ENT (Palliation of tumors of the oral cavity and ablation of leukoplakia of the mouth) - · Thoracic surgery (with the exception of cardiac tissue) - · Proctology (ablation of benign or malignant growths of the anus or rectum, and hemorrhoids) Type of Use (Select one or both, as applicable) | <div> <span> <span style="text-decoration: overline;">☑</span> Prescription Use (Part 21 CFR 801 Subpart D) </span> </div> | |--------------------------------------------------------------------------------------------------------------------------------| | <div> <span> ☐ Over-The-Counter Use (21 CFR 801 Subpart C) </span> </div> | #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {4}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the logo for Galil Medical. The logo consists of a stylized letter "G" with a green dot inside, followed by the text "GALILMEDICAL" in a bold, sans-serif font. Below the logo, there is a tagline that reads "Leading Through Innovation" in a smaller, lighter font. #### K162599 510(k) SUMMARY A summary of 510(k) safety and effectiveness information in accordance with the requirements of 21 CFR 807.92. | Submitter: | Galil Medical Ltd. | |-------------------------------|--------------------------------------------------| | | Tavor Building 1 | | | Industrial Park, PO Box 224 | | | Yokneam Industrial Park 2069203 | | | Israel | | Company Contact Person: | Ms. Lynne A Davies | | | Sr. Manager, Regulatory Affairs | | | Galil Medical Ltd. | | Phone: | 651-287-5098 | | Fax: | 651-287-5099 | | Email: | lynne.davies@btgplc.com | | Alternate Contact Person: | Ms. Amy E McKinney | | | VP, Regulatory Affairs and Quality | | | Galil Medical Ltd. | | Phone: | 651-287-5096 | | Fax: | 651-287-5097 | | Email: | amy.mckinney@btgplc.com | | Device Name: | IcePearl 2.1 CX L and IceFORCE 2.1 CX L | | | Cryoablation Needles | | Device Classification Name: | Cryosurgical unit and accessories (GEH) | | | 21 CFR 878.4350 | | Predicate Devices / Reference | IcePearl 2.1 CX and IceFORCE 2.1 CX Cryoablation | | 510(k): | Needles (K152133) | | Date of Preparation: | September 15, 2016 | #### Device Description: Galil Medical's IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are sterile, single use, disposable components, when used in conjunction with Galil Medical's Visual-ICE Cryoablation System to perform cryoablative destruction of tissue. The needles are intended to convert high-pressure gas to either a very cold freezing application or to a warm thawing application. The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are disposable 2.1 mm needles that have a sharp cutting tip, a color-coded handle, a gas tube, and a connector. The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles offer handles configured in a 90° angled configuration. The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles were designed to provide the same cryoablation functionality with the same iceball shapes as compared to Galil Medical's predicate needles, IcePearl 2.1 CX and IceFORCE 2.1 CX (K152133). {5}------------------------------------------------ The new devices differ from the predicate devices in that the needle shaft is 55 mm longer than the needle shaft of the predicate devices. The longer shaft length was incorporated into the needles to treat deep-seated tumors in patients with a larger body habitus, while still allowing for CT gantry clearance using a 2.1 CX type needle. Galil Medical is using the alpha letter "L" identifier as part of the needle name as well as a different needle part numbers to assist users in distinguishing the different shaft length from the predicate devices. The table below provides a summary comparison of the submitted devices compared to the predicate devices. | Description of Submitted Device: | Comments related to Predicates: | |-----------------------------------------------------------------|-----------------------------------------------------------------------| | IcePearl 2.1 CX L and IceFORCE 2.1 CX L<br>Cryoablation Needles | IcePearl 2.1 CX and IceFORCE 2.1 CX Cryoablation Needles<br>(K152133) | | Design and Construction | | | Needle Tip | Same as predicate | | Needle Shaft | Shaft length is 55 mm longer than predicate | | Gas Pathway Tubing | Same as predicate | | Handle | Same as predicate | | Needle Connector | Same as predicate | | Performance and Function | | | Freezing/Thawing Technology | Same as predicate | | Function | Same as predicate | | Freezing Parameters | Same as predicate | | Thaw Parameters | Same as predicate | | Track Ablation | Same as predicate | | Indications for Use | Same as predicate | In summary, the submitted IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles have the same technology, principle of operation and indications for use as the predicate devices. There are no changes to the Visual-ICE System Software. The previously cleared software is applicable for use with submitted IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles. #### Intended Use: Galil Medical's IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are intended for cryoablative destruction of tissue during surgical procedures. The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, proctology, and urology. The systems are designed to destroy tissue by the application of extreme cold temperatures including prostate and kidney tissue, liver metastases, tumors, skin lesions, and warts. {6}------------------------------------------------ The Galil Medical IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles have the following specific indications: - . Uroloqy (ablation of prostate tissue in cases of prostate cancer and Benign Prostate Hyperplasia "BPH") - Oncology (ablation of cancerous or malignant tissue and benign tumors, and palliative intervention) - Dermatology (ablation or freezing of skin cancers and other cutaneous disorders. Destruction of warts or lesions, angiomas, sebaceous hyperplasia, basal cell tumors of the evelid or canthus area, ulcerated basal cell tumors, dermatofibromas small hemanglomas, mucocele cysts, multiple warts, plantar warts, actinic and seborrheic keratoses, cavernous hemanglomas, perianal condylomata, and palliation of tumors of the skin.) - Gynecology (ablation of malignant neoplasia or benign dysplasia of the female genitalia) - General surgery (palliation of tumors of the rectum, hemorrhoids, anal fissures, pilonidal cysts, and recurrent cancerous lesions, ablation of breast fibroadenoma) - ENT (Palliation of tumors of the oral cavity and ablation of leukoplakia of the mouth) - Thoracic surgery (with the exception of cardiac tissue) - . Proctology (ablation of benign or malignant growths of the anus or rectum, and hemorrhoids) ## Summary of Performance Data and Substantial Equivalence: The IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles use the same technology and have the same intended use and method of operation as compared to the predicate devices. Performance testing was conducted on the IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles with the previously cleared Visual-ICE System Software to verify safety and performance characteristics and to establish substantial equivalence. Testing was conducted according to protocols based on international standards and in-house requirements and included freezing and in vivo performance. Test results demonstrated that the IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles meet defined specifications and do not raise any new safety or effectiveness issues. ## Conclusion: The information and data provided in this Special 510(k) Notification establish that the IcePearl 2.1 CX L and IceFORCE 2.1 CX L Cryoablation Needles are substantially equivalent to the legally marketed predicate devices.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...