sterEOS Workstation

K160914 · Eos Imaging, Inc. · LLZ · Apr 22, 2016 · Radiology

Device Facts

Record IDK160914
Device NamesterEOS Workstation
ApplicantEos Imaging, Inc.
Product CodeLLZ · Radiology
Decision DateApr 22, 2016
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 892.2050
Device ClassClass 2
AttributesSoftware as a Medical Device, Real-World Evidence, Pediatric

Real-World Evidence

SubmissionDeviceSponsorRWD SourcesRWE Use SummaryKey Tags
K160914 · Apr 22, 2016sterEOS WorkstationEos Imaging, Inc.Retrospective clinical image data set (175 patients)The device uses a model of bone structures derived from a retrospective clinical dataset of 175 patients (normal and scoliosis cases) to provide 3D measurement tools for spine and lower limb analysis.Retrospective clinical data; Bone structure model; Scoliosis; Musculoskeletal imaging

Clinical Evidence

Study DesignPopulationComparatorKey Endpoints
A priori image data set for bone structure modeling; Retrospective analysis of clinical image data175 patients (91 normal, 47 moderate idiopathic scoliosis, 37 severe idiopathic scoliosis); Sample Size: 175Not applicable for this studyDevelopment of bone structure model for 3D measurement tools

AI Performance

OutputAlgorithmAcceptanceObservedDev DSDev ReadersTest DSTest Readers
3D spine measurement———175 patients (91 normal patients, 47 patients with moderate idiopathic scoliosis and 37 patients with severe idiopathic scoliosis), and dry isolated vertebrae data.———
3D lower limb measurement———A priori image data set.———

Indications for Use

The sterEOS Workstation is intended for use in the fields of musculoskeletal radiology and orthopedics in both pediatric and adult populations as a general device for acceptance, transfer, display, storage, and digital processing of 2D X-ray images of the musculoskeletal system including interactive 2D measurement tools. When using 2D X-ray images obtained with the EOS imaging EOS System, the sterEOS Workstation provides interactive 3D measurement tools: - To aid in the analysis of scoliosis and related disorders and deformities of the spine in adult patients as well as pediatric patients. The 3D measurement tools include interactive analysis based either on identification of anatomical landmarks for postural assessment or on a model of bone structures derived from an a priori image data set from 175 patients (91 normal patients, 47 patients with moderate idiopathic scoliosis and 37 patients with severe idiopathic scoliosis), and dry isolated vertebrae data for spine model of bone structures is not intended for use to assess individual vertebral abnormalities and is indicated only for patients 7 years and older. For postural assessment, a set of comparative tools is provided allowing the comparison of performed measurements to reference values for patients over 18 years old. - To aid in the analysis of lower limbs alignment and related disorders and deformities based on angle and length measurements. The 3D measurement tools include interactive analysis based either on identification of lower limb alignment landmarks or as for the spine, on a model of bone structures derived from an a priori image data set. The model of bone structures is not intended for use to assess individual bone abnormalities. The 3D package including model-based measurements and torsion angles is indicated only for patients 15 years or older. Only the 2D/3D ruler is indicated for measurements in patients younger than 15 years old.

Device Story

Workstation accepts, transfers, displays, stores, and processes 2D X-ray images of musculoskeletal system; used in radiology/orthopedics. Operates on off-the-shelf hardware; utilizes 2D images from EOS System. Provides interactive 2D/3D measurement tools; 3D analysis uses anatomical landmarks or a priori bone structure models derived from 175-patient dataset and dry vertebrae. Clinicians use output for analysis of scoliosis, spine deformities, and lower limb alignment/torsion. Enhances clinical decision-making by providing quantitative measurements and postural assessment tools. Includes patient database module, DICOM export features, and workflow optimizations.

Clinical Evidence

Bench testing only. Software verification and validation performed at unit and system levels to ensure compliance with specifications, performance, and non-regression. No clinical data presented.

Technological Characteristics

Windows 7 OS; off-the-shelf hardware; DICOM 3.0 support. Features interactive 2D/3D measurement tools, patient database module, and workflow-specific modules for spine and lower limbs. Software-based image processing and analysis.

Indications for Use

Indicated for pediatric and adult patients requiring musculoskeletal radiology and orthopedic analysis. Spine 3D modeling indicated for patients >= 7 years. Lower limb 3D model-based measurements/torsion angles indicated for patients >= 15 years. 2D/3D ruler indicated for all ages. Not for assessment of individual vertebral or bone abnormalities.

Regulatory Classification

Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

Predicate Devices

Reference Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the top half of the circle. Inside the circle is a stylized symbol featuring three human profiles facing to the right, with flowing lines extending from the bottom of the profiles. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 April 22, 2016 EOS Imaging, Inc. % John J. Smith, M.D., J.D. Regulatory Counsel Hogan Lovells U.S. L.L.P. 555 Thirteenth Street, NW WASHINGTON DC 20004 Re: K160914 Trade/Device Name: sterEOS Workstation Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: April 1, 2016 Received: April 1, 2016 Dear Dr. Smith: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {1}------------------------------------------------ If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638 2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours. Michael D.'Hara For Robert Ochs, Ph.D. Director Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ #### 510(k) Number (if known) K160914 #### Device Name #### sterEOS Workstation Indications for Use (Describe) The sterEOS Workstation is intended for use in the fields of musculoskeletal radiology and orthopediativ and adult populations as a general device for acceptance, transfer, display, storage, and digital processing of 2D X-ray images of the musculoskeletal system including interactive 2D measurement tools. When using 2D X-ray images obtained with the EOS imaging EOS System, the sterEOS Workstation provides interactive 3D measurement tools: - To aid in the analysis of scoliosis and related disorders and deformities of the spine in adult patients. The 3D measurement tools interactive analysis based either on identification of anatomical landmarks for postural assessment or on a model of bone structures derived from an a priori image data set from 175 patients, 47 patients with moderate idiopathic scoliosis and 37 patients with scoliosis), and dry isolated vertebrae data for spine modeling. The model of bone structures is not intended for use to assess individual vertebral abnormalities and is indicated only for patients 7 years and older. For postural assessment, a set of comparative tools is provided allowing the comparison of performed measurements to reference values for patients over 18 years old. - To aid in the analysis of lower limbs alignment and deformities based on angle and length measurements. The 3D measurement tools include interactive analysis based either on identification of lower limb alignment landmarks or as for the spine, on a model of bone structures derived from an a priori image data set. The model of bone structures is not intended for use to assess individual bone abnormalities. The 3D package including model-based measurements and torsion angles is indicated only for patients 15 years or older. Only the 2D/3D ruler is indicated for measurements in patients younger than 15 years old. Type of Use (Select one or both, as applicable) X Prescription Use (Part 21 CFR 801 Subpart D) _ Over-The-Counter Use (21 CFR 801 Subpart C) ## PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED. ### FOR FDA USE ONLY Concurrence of Center for Devices and Radiological Health (CDRH) (Signature) This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.qov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ # 510(k) SUMMARY EOS imaging, Inc.'s sterEOS Workstation EOS imaging, Inc. 10 rue Mercoeur PARIS F-75011 FRANCE Phone: + 33 1 55 25 60 60 Facsimile: Mathias Breuil, Regulatory Affairs Project Leader Contact Person: Date Prepared: April 1, 2016 ## Name of Device and Name/Address of Sponsor: sterEOS Workstation EOS imaging, Inc. 10 rue Mercoeur PARIS F-75011 FRANCE | Trade Name: | sterEOS Workstation | |-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Common or Usual Name: | Image processing radiological system | | Classification Name: | 21 C.F.R. 892.2050; Picture archiving and communications system<br>Product Code LLZ - system, image processing, radiological | | Predicate Device: | 510(k) number: K141137<br>Trade/Device Name: sterEOS Workstation<br>Clearance Date: September 15, 2014<br>Regulation Number: 21 CFR 892.2050<br>Regulation Name: Picture archiving and communications system<br>Regulatory Class: II<br>Product Code: LLZ | ## Device Description The sterEOS Workstation is a general system for acceptance, transfer, display, storage, and digital processing of 2D X-ray images of the musculoskeletal system, including interactive 2D measurement tools. When used with 2D X-ray images obtained with the EOS imaging's EOS System (K152788), the sterEOS Workstation provides interactive 3D measurement tools to aid in the analysis of skeletal {4}------------------------------------------------ deformities in spine and lower limbs. ## Intended Use/ Indications for Use The sterEOS Workstation is intended for use in the fields of musculoskeletal radiology and orthopedics in both pediatric and adult populations as a general device for acceptance, transfer, display, storage, and digital processing of 2D X-ray images of the musculoskeletal system including interactive 2D measurement tools. When using 2D X-ray images obtained with the EOS imaging EOS System, the sterEOS Workstation provides interactive 3D measurement tools: - . To aid in the analysis of scoliosis and related disorders and deformities of the spine in adult patients as well as pediatric patients. The 3D measurement tools include interactive analysis based either on identification of anatomical landmarks for postural assessment or on a model of bone structures derived from an a priori image data set from 175 patients (91 normal patients, 47 patients with moderate idiopathic scoliosis and 37 patients with severe idiopathic scoliosis), and dry isolated vertebrae data for spine model of bone structures is not intended for use to assess individual vertebral abnormalities and is indicated only for patients 7 years and older. For postural assessment, a set of comparative tools is provided allowing the comparison of performed measurements to reference values for patients over 18 years old. - . To aid in the analysis of lower limbs alignment and related disorders and deformities based on angle and length measurements. The 3D measurement tools include interactive analysis based either on identification of lower limb alignment landmarks or as for the spine, on a model of bone structures derived from an a priori image data set. The model of bone structures is not intended for use to assess individual bone abnormalities. The 3D package including model-based measurements and torsion angles is indicated only for patients 15 years or older. Only the 2D/3D ruler is indicated for measurements in patients younger than 15 years old. # Technological Characteristics The technological characteristics of the modified sterEOS Workstation are essentially identical to the cleared sterEOS Workstation (K14137). Like the cleared predicate, the subject device is based on the Windows 7 operating system, runs on off-the-shelf hardware, supports DICOM 3.0 formatted images, and has a user interface that follows typical clinical workflow patterns to process, review, and analyze digital images. The main differences with the cleared sterEOS Workstation consist of the following minor software modifications: - -Addition of information in the User Manual concerning the patient position on X-ray images for the 3D modeling; - । Integration of Patient Database module to improve the sterEOS patient list performances and DICOM functionalities; {5}------------------------------------------------ - । Simplification of pelvic parameters identification; - -Reorganization of sterEOS 3D module's lower limbs workflows; - -Addition of a new clinical parameter in the global posture workflow; - -Addition of export features to allow for the transfer of sets of data for third-party applications; and - -Various bug corrections. Minor hardware modifications were also made to enhance usability. ## Performance Data Software modifications have been verified at the unit level. After integration, system software verification and validation testing was performed to ensure compliance with specifications, performance and non-regression. Additional performance and functional testing has confirmed the equivalent performance of the modified sterEOS Workstation compared to the predicate sterEOS. ## Substantial Equivalence The device has the same intended use and indications, and very similar technological characteristics and principles of operation, as its predicate device. The minor differences between the device and its predicate raise no different questions of safety or effectiveness. Performance data demonstrate that the device is as safe and effective as the company's cleared sterEOS Workstation (K14137) and, thus, is substantially equivalent.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...