WOlf High Speed Handpieces - Medium head, WOlf High Speed Handpieces - Small head
K160410 · Dental Savings Club · EFB · Sep 29, 2016 · Dental
Device Facts
| Record ID | K160410 |
| Device Name | WOlf High Speed Handpieces - Medium head, WOlf High Speed Handpieces - Small head |
| Applicant | Dental Savings Club |
| Product Code | EFB · Dental |
| Decision Date | Sep 29, 2016 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.4200 |
| Device Class | Class 1 |
| Attributes | Therapeutic |
Intended Use
WOlf High Speed Handpieces are used intra-orally by trained dental professionals for drilling and preparation of dental cavities for restoration, such as fillings.
Device Story
WOlf High Speed Handpieces are dental instruments used by trained dental professionals in clinical settings. The device functions as a high-speed drill for the preparation of dental cavities and removal of tooth structure during restorative procedures like fillings. It is a mechanical tool operated by the clinician to facilitate dental restoration. The device aids in the removal of decayed or damaged tooth material, allowing for the placement of restorative materials. It does not involve software, AI, or automated processing.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
High-speed dental handpiece; mechanical operation; intended for intra-oral use; Class I device (21 CFR 872.4200).
Indications for Use
Indicated for intra-oral use by trained dental professionals for drilling and preparation of dental cavities for restoration (e.g., fillings).
Regulatory Classification
Identification
A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.
Related Devices
- K202674 — Medidenta High Speed Handpieces · Pac-Dent, Inc. · Dec 12, 2022
- K061581 — EXCEL HIGH SPEED DENTAL HANDPIECE · Orthosource, Inc. · Aug 16, 2006
- K960719 — STAR DENTAL 430 SERIES HIGH SPEED HANDPIECE · Dentalez Group · Mar 28, 1996
- K181900 — Dental high speed handpiece, Dental low speed handpiece · Foshan Cicada Dental Instrument Co, Ltd. · Dec 9, 2019
- K030133 — SOLARA SERIES COMPRISED OF THE SOLARA HIGH SPEED DENTAL HANDPIECE AND THE SOLARA PLUS HIGH SPEED DENTAL HANDPIECE · Dentalez Group · Apr 29, 2003
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" written around it. Inside the circle is a stylized image of three human profiles facing to the right, stacked on top of each other.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
September 29, 2016
Dental Savings Club c/o Mr. Gordon Wehner President QualMed Corporation 23 Forestview Dr. Cambridge, N1T1V1 ON Canada
Re: K160410 Trade/Device Name: WOlf High Speed Handpieces Regulation Number: 21 CFR 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: Class I Product Code: EFB Dated: August 26, 2016 Received: August 30, 2016
Dear Mr. Wehner:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Image /page/1/Picture/8 description: The image shows a signature followed by the name Tina Kiang. Below the signature is the letter -S. In the background, the letters FDA are visible in a light gray color.
Tina Kiang, Ph.D. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known)
## k160410
Device Name WOlf High Speed Handpieces
Indications for Use (Describe)
WOlf High Speed Handpieces are used intra-orally by trained dental professionals for drilling and preparation of dental cavities for restoration, such as fillings.
Type of Use (Select one or both, as applicable)
> Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
## CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Form Approved: OMB No. 0910-0120 Expiration Date: January 31, 2017 See PRA Statement below.