OTC COMBO TENS/EMS SYSTEM

K141299 · Well-Life Healthcare Limited · NUH · Nov 14, 2014 · Neurology

Device Facts

Record IDK141299
Device NameOTC COMBO TENS/EMS SYSTEM
ApplicantWell-Life Healthcare Limited
Product CodeNUH · Neurology
Decision DateNov 14, 2014
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.5890
Device ClassClass 2
AttributesTherapeutic

Intended Use

For temporary relief of pain associated with sore and aching muscles in the lower back due to strain from exercise or normal household and work activities. (Choose TENS Modes P1 through P7) For temporary relief of pain associated with sore and lower extremities ( arm and/or leg) due to strain from exercise or normal household and work activities.(Choose TENS Modes P1 through P7) For symptomatic relief and management of chronic, intractable pain associated with arthritis. ( Choose TENS Modes P8) For use by healthy adults for the stimulation of healthy muscles in order to improve or facilitate muscle performance. ( Choose EMS Modes P1 through P6)

Device Story

OTC Combo TENS/EMS System (model WL-2405) is a dual-modality stimulator for over-the-counter use. Device delivers electrical pulses via skin electrodes to provide TENS (pain relief) or EMS (muscle stimulation). User selects from pre-programmed modes (TENS P1-P8; EMS P1-P6) based on desired application. TENS modes target muscle strain and chronic arthritis pain; EMS modes target healthy muscle performance. Device operates via battery-powered electrical stimulation; output intensity and mode are controlled by the user. Provides non-pharmacological pain management and muscle conditioning.

Clinical Evidence

Bench testing only.

Technological Characteristics

Dual-modality TENS/EMS stimulator. Features multiple pre-programmed stimulation modes (TENS P1-P8, EMS P1-P6). Battery-powered. Form factor designed for portable, over-the-counter use. Output parameters are user-selectable.

Indications for Use

Indicated for healthy adults for temporary relief of pain in lower back and extremities (arm/leg) due to strain from exercise or daily activities; symptomatic relief/management of chronic, intractable pain from arthritis; and stimulation of healthy muscles to improve/facilitate muscle performance.

Regulatory Classification

Identification

A transcutaneous electrical nerve stimulator for pain relief is a device used to apply an electrical current to electrodes on a patient's skin to treat pain.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized caduceus, which is a symbol often associated with medicine and healthcare. The caduceus is formed by three human profiles facing to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the caduceus. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 November 14, 2014 Well-Life Healthcare Limited Jenny Hsieh 1FL, No. 16, Lane 454 Jungjeng Rd. Yunghe City, Taipei County TAIWAN, ROC Re: K141299 Trade/Device Name: OTC Combo TENS/EMS System, model WL-2405 Regulation Number: 21 CFR 882.5890 Regulation Name: Transcutaneous electrical nerve stimulator for pain relief Regulatory Class: Class II Product Code: NUH, NGX, NYN Dated: October 13, 2014 Received: October 14, 2014 Dear Ms. Hsieh, We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set {1}------------------------------------------------ forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # Felipe Aquel -S for Carlos L. Peña, PhD, MS Director Division of Neurological and Physical Medicine Devices Office of Device Evaluation Center for Devices and Radiological Health {2}------------------------------------------------ ## Indications for Use 510(k) Number (if known) K141299 Device Name OTC Combo TENS/EMS System, model: WL-2405 Indications for Use (Describe) For temporary relief of pain associated with sore and aching muscles in the lower back due to strain from exercise or normal household and work activities. (Choose TENS Modes P1 through P7) For temporary relief of pain associated with sore and lower extremities ( arm and/or leg) due to strain from exercise or normal household and work activities.(Choose TENS Modes P1 through P7) For symptomatic relief and management of chronic, intractable pain associated with arthritis. ( Choose TENS Modes P8) For use by healthy adults for the stimulation of healthy muscles in order to improve or facilitate muscle performance. ( Choose EMS Modes P1 through P6) Type of Use (Select one or both, as applicable) Prescription Use (Part 21 CFR 801 Subpart D) × Over-The-Counter Use (21 CFR 801 Subpart C) ### PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED. #### FOR FDA USE ONLY Concurrence of Center for Devices and Radiological Health (CDRH) (Signature) {3}------------------------------------------------ This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...