K133993 · Pie Medical Imaging · IZI · Mar 25, 2014 · Radiology
Device Facts
Record ID
K133993
Device Name
CAAS WORKSTATION
Applicant
Pie Medical Imaging
Product Code
IZI · Radiology
Decision Date
Mar 25, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.1600
Device Class
Class 2
Attributes
Software as a Medical Device
Indications for Use
CAAS Workstation is a modular software product intended to be used by or under supervision of a cardiologist or radiologist in order to aid in reading and interpreting cardiovascular X-Ray images to support diagnoses and for assistance during intervention of cardiovascular conditions.
Device Story
CAAS Workstation is a standalone modular software product for PCs running Windows; processes vendor-independent DICOM X-ray angiography images. Input data undergoes manual and semi-automatic contour detection to define centerlines and boundaries of coronary/peripheral vessels and ventricles. Analysis modules (QCA, QCA3D, QVA, LVA, RVA, StentEnhancer) perform quantitative measurements including vessel dimensions, stenosis, wall motion, and density. StentEnhancer module provides enhanced visualization and stent dimension measurement. Results are displayed on-screen for clinician review and can be exported in various electronic formats. Used by cardiologists or radiologists in clinical settings to support diagnosis and interventional procedures; output serves as an aid rather than the sole basis for clinical decision-making. Benefits include standardized quantification of cardiovascular structures and improved visualization of stents to assist in procedural guidance.
Clinical Evidence
Bench testing only. No clinical data. Performance verified through system testing and validation of analysis algorithms. Regression testing performed on previously cleared modules to verify numerical equivalence. Safety and effectiveness demonstrated through verification of risk control measures and adherence to software lifecycle standards.
Technological Characteristics
Standalone modular software for Windows PC. Inputs: DICOM X-ray angiography. Processing: Semi-automatic contour detection, 3D reconstruction, and quantitative analysis modules. Connectivity: DICOM-compliant. Standards: ISO 14971:2007 (risk management), NEMA PS 3.1-3.20 (DICOM), IEC 62304 (software lifecycle).
Indications for Use
Indicated for cardiologists or radiologists to aid in reading/interpreting cardiovascular X-ray images for diagnosis and intervention. Features include segmentation of cardiovascular structures, 3D reconstruction of vessel segments, measurement of cardiovascular dimensions, quantification of stenosis in coronary/peripheral vessels, quantification of left/right ventricular wall motion, density measurements, determination of optimal C-arm position, and stent visualization/measurement.
Regulatory Classification
Identification
An angiographic x-ray system is a device intended for radiologic visualization of the heart, blood vessels, or lymphatic system during or after injection of a contrast medium. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
{1}------------------------------------------------
**MAR 2 5 2014** KB33993
PIE MEDICAL Page 1 of 4
IMAGING
| 510(k) Summary | CAAS Workstation | [GEN1632]v2.0 | | New Device | Predicate Device | Predicate Device | Predicate Device |
|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------|
| Submitter/Owner Name | Pie Medical Imaging BV | | Device name | CAAS Workstation | CAAS | CAAS QxA3D | IC-PRO System |
| Address | Philipsweg 1, 6227 AJ Maastricht, The Netherlands | | Manufacturer | Pie Medical Imaging | Pie Medical Imaging | Pie Medical Imaging | Paieon |
| Phone Number | +31 43 32 81 328 | | 510(k) number | | K052988 | K100292 | K110256 |
| Fax Number | +31 43 32 81 329 | | Data type | X-Ray Angiography<br>data in DICOM format<br>(vendor independent) | X-Ray Angiography<br>data in DICOM format<br>(vendor independent) | X-Ray Angiography<br>data in DICOM format<br>(vendor independent) | X-Ray Angiography<br>data in DICOM format<br>(vendor independent) |
| Contact Person: | Florie Daniels, Product Registration Coordinator | | Import of Patient<br>Data | Manual through<br>keyboard<br>Command line<br>interface | Manual through<br>keyboard<br>Command line<br>interface | Manual through<br>keyboard<br>Command line<br>interface | Manual through<br>keyboard<br>Command line<br>interface |
| Email Address | Florie.Daniels@pie.nl | | Contour<br>Definition | Manual and semi-<br>automatic centerline<br>definition based<br>contour detection of<br>coronary and<br>peripheral vessel<br>Manual and semi-<br>automatic left<br>ventricular contour<br>definition<br>Manual right<br>ventricular contour<br>definition<br>Manual stent contour<br>definition<br>Contour correction and<br>restriction | Manual and semi-<br>automatic centreline<br>definition based<br>contour detection of<br>coronary and<br>peripheral vessel<br>Manual and semi-<br>automatic left<br>ventricular contour<br>definition<br>Manual right<br>ventricular contour<br>definition<br>Contour correction and<br>restriction | Manual and semi-<br>automatic centreline<br>definition based<br>contour detection of<br>coronary and<br>peripheral vessel<br>Contour correction and<br>restriction | Manual stent contour<br>definition<br>Contour correction |
| Preparation Date | 24-Dec-2013 | | Image Display | 2D X-Ray image<br>3D coronary vessel<br>reconstruction | 2D X-Ray image | 2D X-Ray image<br>3D coronary and<br>peripheral vessel<br>reconstruction | 2D X-Ray image |
| Trade Name | CAAS Workstation | | Image<br>Assessment | Manual and automatic<br>calibration<br>Basic length, diameter,<br>density and angle<br>measurements<br>Vessels and ventricle<br>dimensions (diameters,<br>areas, volumes)<br>Automatic and manual<br>stenosis assessment<br>3D coronary vessel<br>reconstruction<br>Left and right | Manual and automatic<br>calibration<br>Basic length, diameter,<br>density and angle<br>measurements<br>Vessels and ventricle<br>dimensions (diameters,<br>areas, volumes)<br>Automatic and manual<br>stenosis assessment<br>Left and right<br>ventricular wall motion | Automatic calibration<br>Automatic and manual<br>stenosis assessment<br>3D coronary and<br>peripheral vessel<br>reconstruction | Enhanced stent<br>visualization<br>Stent dimensions |
| Common Name | Cardiovascular Angiography Analysis System (CAAS) | | | Left and right | Left ventricular | | |
| Classification | Classification Name: Angiographic X-ray System<br>Regulation Class: Class II<br>Regulation number: 21 CFR 892.1600<br>Classification Product Code: IZI<br>Subsequent Product Code: LLZ | | | | | | |
| Predicate Devices | CAAS (K052988)<br>CAAS QxA3D (K100292)<br>IC-PRO System (K110256) | | | | | | |
| Device Description | CAAS Workstation is designed as a stand-alone modular software product for<br>viewing and quantification of X-ray angiographic images intended to run on a PC<br>with a Windows operating system. CAAS Workstation contains the analysis<br>modules QCA, QCA3D, QVA, LVA, RVA and StentEnhancer.<br>The analysis modules QCA, QCA3D, QVA, LVA and RVA contain functionality<br>of the previously cleared predicate devices CAAS (K052988) and CAAS QxA3D<br>(K100292) for calculating dimensions of coronary and peripheral vessels and the<br>left and right ventricles, quantification of stenosis, performing density<br>measurements and determination of optimal C-arm position for imaging of vessel<br>segments. Semi-automatic contour detection forms the basis for the analyses.<br>Functionality to enhance the visualization of a stent and to measure stent<br>dimension is added by means of the analysis module StentEnhancer. This<br>functionality is based on the StentOptimizer module of the IC-PRO System<br>(K110256).<br>The quantitative results CAAS Workstation support diagnosis and intervention of<br>cardiovascular conditions.<br>The analysis results are available on screen, and can be exported in various<br>electronic formats.<br>The functionality is independent of the type of vendor acquisition equipment. | | | | | | |
| Intended Use | CAAS Workstation is a modular software product intended to be used by or under<br>supervision of a cardiologist or radiologist in order to aid in reading and<br>interpreting cardiovascular X-Ray images to support diagnoses and for assistance<br>during intervention of cardiovascular conditions. | | | | | | |
{2}------------------------------------------------
Indications for Use
CAAS Workstation features segmentation of cardiovascular structures, 3D reconstruction of vessel segments based on multiple angiographic images, measurement and reporting tools to facilitate the following use:
- Calculate the dimensions of cardiovascular structures;
- Quantify stenosis in coronary and peripheral vessels;
- Quantify the motion of the left and right ventricular wall;
- Perform density measurements;
- Determine C-arm position for optimal imaging of cardiovascular structures;
· Enhance stent visualization and measure stent dimensions.
CAAS Workstation is intended to be used by or under supervision of a cardiologist or radiologist. When the results provided by CAAS Workstation are used in a clinical setting to support diagnoses and for assistance during intervention of cardiovascular conditions, the results are explicitly not to be regarded as the sole, irrefutable basis for clinical decision making.
Technological Characteristics Comparison
A comparison of the technological characteristics of the predicate and subject device is given the table below.
{3}------------------------------------------------
| | New Device | Predicate Device | Predicate Device | Predicate Device |
|--------------------|--------------------------------------------------------------------------------------------------------------|---------------------------------------|---------------------------------------|------------------|
| Device name | CAAS Workstation | CAAS | CAAS QxA3D | IC-PRO System |
| Manufacturer | Pic Medical Imaging | Pie Medical Imaging | Pie Medical Imaging | Paeion |
| 510(k) number | | K052988 | K100292 | K110256 |
| | ventricular wall motion Left ventricular myocardium dimensions Enhanced stent visualization Stent dimensions | myocardium dimensions | | |
| Storage of Results | Printout Images XML DICOM SC PDF | Printout Images XML DICOM SC DICOM SR | Printout Images XML DICOM SC DICOM SR | Printout Images |
| Operating System | Windows | Windows | Windows | Windows |
All technological characteristics of the subject device are similar to the cleared predicate devices.
Conformance Standards The device complies with the following conformance standards:
- ISO 14971:2007, Medical devices Application of risk management to � medical devices
- . NEMA PS 3.1 - 3.20 (2011), Digital Imaging and Communication in Medicine (DICOM) Set. (Radiology)
- IEC 62304 First edition 2006-05, Medical device software Software life . cycle processes
System requirements - derived from the intended use and indications for use - as Performance Data well as risk control measures are verified by system testing. For each analysis module a validation approach is created and the proper functioning of the algorithms is validated. For analysis modules already implemented in earlier versions of CAAS regression testing is performed to verify equivalence in numerical results. The test results demonstrate safety and effectiveness of CAAS Workstation in relation to its intended use and that CAAS Workstation is considered as safe and effective as the predicate devices.
- Substantial Equivalence The analysis modules QCA, QVA, I.VA, RVA in the previously cleared device CAAS' (K052988) and the analysis module QCA3D in the previously cleared device 'CAAS QxA3D' (K100292) are available in CAAS Workstation and are similar in terms of intended use and indications for use and in functionality. The analysis module 'StentEnhancer' has been added in CAAS Workstation and is similar in terms of intended use, indications for use and technology as the · StentOptimizer module available in 'The IC-PRO System' (K110256).
- The testing reported in this 510(k) demonstrates that CAAS Workstation is Conclusion substantially equivalent to a combination of the predicate devices in terms of intended use, indications for use, technological characteristics, measurements and operating environment. As such CAAS Workstation is considered as safe and effective as its predicate devices and performs as well as the predicate devices.
{4}------------------------------------------------
K133993
Page 4 of 4
.
{5}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird-like symbol with three curved lines representing its wings or body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the symbol.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
March 25, 2014
Pie Medical Imaging, B.V. % Ms. Florie Daniels Regulatory Affairs Coordinator Philipsweg I Maastricht Limburg, 6227 AJ THE NETHERLANDS
Re: K133993 Trade/Device Name: CAAS Workstation Regulation Number: 21 CFR 892.1600 Regulation Name: Angiographic x-ray system Regulatory Class: II Product Code: IZI, LLZ Dated: December 24, 2013 Received: December 26, 2013
Dear Ms. Daniels:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA 's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{6}------------------------------------------------
Page 2-Ms. Daniels
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638 2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Smh.7)
for
Janine M. Morris Director. Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
## Indications for Use
510(k) Number (if known) K133993
Device Name CAAS Workstation
CAAS Workstation features segmentation of cardiovascular structures, 3D reconstruction of vessel segments based on multiple angiographic images, measurement and reporting tools to facilitate the following use:
- Calculate the dimensions of cardiovascular structures;
- Quantify stenosis in coronary and peripheral vessels;
- Quantify the motion of the left and right ventricular wall;
- Perform density measurements:
- Determine C-arm position for optimal imaging of cardiovascular structures;
- Enhance stent visualization and measure stent dimensions.
CAAS Workstation is intended to be used by or under supervision of a cardiologist. When the results provided by CAAS Workstation are used in a clinical setting to support diagnoses and for assistance during intervention of cardiovascular conditions, the results are explicitly not to be regarded as the sole, irrefutable basis for clinical decision making.
Type of Use (Select one or both, as applicable)
Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
Form Approved: OMB No. 0910-0120
Expiration Date: January 31, 2017
See PRA Statement below.
## PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.
## FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
Smh.7)
This section applies only to requirements of the Paperwork Reduction Act of 1995.
## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW."
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, fo:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.