REPROCESSED LIGASURE BLUNT TIP LAPAROSCOPIC SEALER/DIVIDER

K133578 · Stryker Sustainability Solutions · NUJ · Apr 10, 2014 · General, Plastic Surgery

Device Facts

Record IDK133578
Device NameREPROCESSED LIGASURE BLUNT TIP LAPAROSCOPIC SEALER/DIVIDER
ApplicantStryker Sustainability Solutions
Product CodeNUJ · General, Plastic Surgery
Decision DateApr 10, 2014
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4400
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider is a bipolar electrosurgical instrument intended for use with the ForceTriad Energy Platform in general and gynecologic laparoscopic surgical procedures where ligation and division of vessels and lymph is desired. The instrument creates a seal by application of RF electrosurgical energy to vascular structures (vessels and lymph) interposed between the jaws of the instrument. A blade within the instrument is surgeon actuated to divide tissue. Indications for use include general laparoscopic procedures including urologic, vascular. thoracic and thoracoscopic, and gynecologic procedures where ligation and division of vessels is performed. These procedures include: laparoscopically assisted vaginal hysterectomy, Nissen fundoplication, colectorny, adhesiolysis, oophorectomy, etc. The device has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures, and should not be used for these procedures. The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider can be used on vessels and lymphatics up to and including 7mm and tissue bundles as large as will fit in the jaws of the instrument.

Device Story

Reprocessed bipolar electrosurgical instrument; 5mm diameter, 37cm length. Used with ForceTriad Energy Platform for laparoscopic vessel/lymph ligation and division. Surgeon-operated via handle controls: jaw lever, activation button, cutter trigger, rotation knob. Device identifies itself to generator via Smart™ connector. RF energy seals vascular structures; manual blade actuation divides tissue. Used in OR by surgeons. Benefits: enables minimally invasive vessel sealing/division. Reprocessing involves cleaning, decontamination, and functional testing.

Clinical Evidence

Bench testing only. Included biocompatibility, reprocessing validation, sterilization validation, functional performance tests, and packaging validation. No clinical data provided.

Technological Characteristics

Bipolar electrosurgical instrument; 5mm shaft diameter, 37cm length. Energy source: RF via ForceTriad Energy Platform. Connectivity: Smart™ connector for generator identification. Reprocessed device; sterilization validated. Mechanical controls: jaw lever, cutter trigger, rotation knob.

Indications for Use

Indicated for general, gynecologic, urologic, vascular, and thoracic laparoscopic procedures requiring ligation and division of vessels/lymphatics up to 7mm and tissue bundles. Contraindicated for tubal sterilization or tubal coagulation.

Regulatory Classification

Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## K133578 ### SECTION 5: 510(k) SUMMARY APR 1 0 2014 #### Submitter: Stryker Sustainability Solutions 1810 W. Drake Drive Tempe, Arizona 85283 #### Contact: Jill M. Clark Senior Regulatory Affairs Specialist (480) 763-5300 (o) (480) 763-5310 (f) jill.clark@stryker.com Ramona Kulik Staff Specialist Regulatory Affairs 480-763-5300 (o) 480-763-2952 (f) ramona.kulik@stryker.com | Date of Preparation: | November 19, 2013 | |-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------| | Name of Device: | | | Trade/Proprietary Name: | Reprocessed LigaSure™ Blunt Tip Laparoscopic<br>Sealer/Divider | | Common Name: | Bipolar Electrosurgical Open and Laparoscopic Instrument | | Classification Name: | Electrosurgical, Cutting & Coagulation Accessories,<br>Laparoscopic & Endoscopic, Reprocessed<br>(21 CFR§878.4400, Product Code NUJ, Class II) | #### Predicate Device: | Model<br>Number | 510(k)<br>Number | 510(k) Title | Original Manufacturer | |-----------------|------------------|-------------------------------------------------------|--------------------------------------------| | LF1537 | K092879 | LigaSure 5mm Blunt Tip<br>Laparoscopic Sealer-Divider | Valleylab<br>(currently known as Covidien) | #### Device Description: The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider is a multifunctional electrosurgical instrument for use in performing laparoscopic surgical procedures using the ForceTriad™ Energy Platform. The outer diameter of the instrument shaft is 5 mm, with a working length of 37 cm. The following controls are located on the instrument handle: > Stryker Sustainability Solutions > Reprocessed LlgaSure™ Blunt Tip Laparoscopic Sealer/Divider Traditional 510(k) {1}------------------------------------------------ - A lever for opening and closing the instrument jaws. The mechanism incorporates a . latch to hold the jaws in the closed position during vessel sealing and cutting. - An activation button for generator power to initiate vessel sealing. . - A trigger for actuating the cutter. The cutter can only be actuated when the jaws are . closed and latched. - . A knob to rotate the instrument jaws. All controls can be operated with either the right or left hand. Vessel sealing can be initiated using the activation button or utilizing a footswitch connected to the generator. The instrument attaches to the generator via a ten-foot cable with a Smart™ connector that identifies the instrument type to the generator. The instrument is supplied sterile for single use. The scope of this submission only includes the reprocessed Covidien 100 sealer/divider device and not the ForceTriad™ Energy Platform. Stryker Sustainability Solutions does not reprocess or market the generator. #### Intended Use: The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider is a bipolar electrosurgical instrument intended for use with the ForceTriad Energy Platform in general and gynecologic laparoscopic surgical procedures where ligation and division of vessels and lymph is desired. The instrument creates a seal by application of RF electrosurgical energy to vascular structures (vessels and lymph) interposed between the jaws of the instrument. A blade within the instrument is surgeon actuated to divide tissue. Indications for use include general laparoscopic procedures including urologic, vascular. thoracic and thoracoscopic, and gynecologic procedures where ligation and division of vessels is performed. These procedures include: laparoscopically assisted vaginal hysterectomy, Nissen fundoplication, colectorny, adhesiolysis, oophorectomy, etc. The device has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures, and should not be used for these procedures. The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider can be used on vessels and lymphatics up to and including 7mm and tissue bundles as large as will fit in the jaws of the instrument. #### Summary of Technological Characteristics: The design, materials, and intended use of Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider are equivalent to the predicate device. The mechanism of action of the reprocessed device is identical to the predicate device in that the same standard mechanical design, materials, and size are utilized. There are no changes to the claims, intended use, clinical applications, patient population, performance specifications, or method of operation. In addition, Stryker Sustainability Solutions' reprocessing of Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Dividers includes removal of adherent visible soil and decontamination. Each individual device is {2}------------------------------------------------ tested for appropriate function of its components prior to packaging and labeling operations. #### Performance Data: Bench and laboratory testing was conducted to demonstrate performance (safety and effectiveness) of Reprocessed LigaSure 1 Blunt Tip Laparoscopic Sealer/Dividers. This included the following tests: - . Biocompatibility - Validation of Reprocessing . - . Sterilization Validation - . Functional Performance Tests - Packaging Validation . Performance testing demonstrates that reprocessed devices perform as originally intended. #### Conclusion: Stryker Sustainability Solutions concludes that the Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider is at least as safe and effective to the predicate device as described herein. # Stryker Sustainability Solutions Traditional 510(k) {3}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or bird in flight, composed of three curved lines. #### DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 April 10, 2014 Stryker Sustainability Solutions Ms. Jill Clark Senior Regulatory Affairs Specialist 1810 West Drake Drive Tempe, Arizona 85283 Re: K133578 Trade/Device Name: Reprocessed LigaSure" Blunt Tip Laparoscopic Sealer/Divider Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical cutting and coagulation device and accessories Regulatory Class: Class II Product Code: NUJ Dated: March 10, 2014 Received: March 11, 2014 Dear Ms. Clark: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you: however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set {4}------------------------------------------------ Page 2 - Ms. Jill Clark forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours. # David Krause -S for Binita S. Ashar, M.D., M.B.A., F.A.C.S. Acting Director Division of Surgical Devices Office of Device Evaluation Center for Devices and : Radiological Health Enclosure {5}------------------------------------------------ #### SECTION 4: INDICATIONS FOR USE STATEMENT #### 510(k) Number (if known): K133578 Device Name: Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider Indications For Use: The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider is a bipolar electrosurgical instrument intended for use with the ForceTriad™ Energy Platform in general and gynecologic laparoscopic surgical procedures where ligation and division of vessels and lymph is desired. The instrument creates a seal by application of RF electrosurgical energy to vascular structures (vessels and lymph) interposed between the jaws of the instrument. A biade within the instrument is surgeon actuated to divide tissue. Indications for use include general laparoscopic procedures including urologic, vascular, thoracic and thoracoscopic, and gynecologic procedures where ligation and division of vessels is performed. These procedures include: laparoscopically assisted vaginal hysterectorny, Nissen fundoplication, colectomy, adhesiolysis, oophorectomy, etc. The device has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures, and should not be used for these procedures. The Reprocessed LigaSure™ Blunt Tip Laparoscopic Sealer/Divider can be used on vessels and lymphatics up to and including 7mm and tissue bundles as large as will fit in the jaws of the instrument. Prescription Use × AND/OR (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) # Joshua C. Nipper -S Traditional 510(k)
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...