← Product Code [BSO](/productcode/BSO) · K133316

# SPIROL  BLOCK (19 GA. OPEN END MODELS), (20 GA. OPEN END MODELS), (19 GA. CLOSED END MODELS), (20 GA. CLOSED END MODELS) (K133316)

_Epimed International, Inc. · BSO · May 28, 2014 · Anesthesiology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K133316

## Device Facts

- **Applicant:** Epimed International, Inc.
- **Product Code:** [BSO](/productcode/BSO.md)
- **Decision Date:** May 28, 2014
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 868.5120
- **Device Class:** Class 2
- **Review Panel:** Anesthesiology
- **Attributes:** Therapeutic

## Indications for Use

The catheter is designed to deliver anesthesia to manage perioperative pain and/or alleviate postoperative analgesia.

## Device Story

Spirol® Block is a single-use, disposable peripheral nerve block catheter; 19 Ga. or 20 Ga. sizes; 14" to 24" length. Device consists of a polymer-coated stainless steel spring; available in open/closed-ended and styletted/non-styletted configurations. Internal radiopaque, echogenic coiled wire allows visualization via fluoroscopy or ultrasound. Physician inserts catheter via introducer needle to target peripheral nerve group; needle is withdrawn. Catheter connects to standard Luer-lock accessories (bacterial filter, extension set, pump/syringe) via included connector. Enables continuous or bolus delivery of anesthetic agents to manage perioperative/postoperative pain. Used in clinical settings by trained physicians. Benefits include kink resistance, structural integrity, and sustained analgesic delivery for up to 72 hours.

## Clinical Evidence

Bench testing only. Performance testing included dimensional analysis, substance compatibility, kink testing, stiffness, tensile strength, connector attachment, flow rate, leakage resistance (aspiration/vacuum/pressure), corrosion resistance, and skive testing. Biocompatibility testing performed per ISO 10993-3, -5, -6, -10, and -11.

## Technological Characteristics

Polymer-coated stainless steel spring catheter; 19 Ga. or 20 Ga. diameters; 14-24 inch lengths. Features internal radiopaque, echogenic coiled wire. Single-use, disposable. Connects via Luer-lock. Biocompatibility per ISO 10993. No electronic components or software.

## Regulatory Identification

An anesthesia conduction catheter is a flexible tubular device used to inject local anesthetics into a patient and to provide continuous regional anesthesia.

## Predicate Devices

- Feth-R-Kath ([K981329](/device/K981329.md))
- ARROW FlexBlock Continuous Peripheral Nerve Block Catheter ([K122027](/device/K122027.md))

## Reference Devices

- Epimed catheter connector ([K051171](/device/K051171.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the logo for "Epimed - Designed by Experts for Experts". The logo is in black and white. The word "Epimed" is in a bold, sans-serif font, with a geometric shape to the left of the word. Below the word "Epimed" is the tagline "Designed by Experts for Experts" in a smaller font.

# 510(k) Summar

### Submitter Information:

| Name:             | Epimed International, Inc.                                                 |
|-------------------|----------------------------------------------------------------------------|
| Address:          | 141 Sal Landrio Drive<br>Crossroads Business Park<br>Johnstown, N.Y. 12095 |
| Telephone Number: | (518) 725-0209                                                             |
| Fax Number:       | (518) 725-0207                                                             |
| Contact Person:   | Preston H. Frasier<br>Manager - QA/RA                                      |
| Telephone Number: | (518) 725-0209 Ext. 1300                                                   |
| Email Address:    | prestonf@epimedint.com                                                     |
| Date Prepared:    | October 23rd, 2013                                                         |

### Device Name & Classification:

| Device Trade Name:   | Spirol® Block Continuous Peripheral Nerve Block Catheter |
|----------------------|----------------------------------------------------------|
| Common Name:         | Peripheral Nerve Block Catheter                          |
| Classification Name: | Anesthesia Conduction Catheter, BSO (21 CFR 868.5120)    |

### Predicate Device(s) Information:

| Predicate Device #1: | Epimed International's "Feth-R-Kath" (K981329)<br>• Catheter later renamed “Spirol®” by Epimed. |
|----------------------|-------------------------------------------------------------------------------------------------|
| Predicate Device #2: | Arrow International's “ARROW FlexBlock Continuous<br>Peripheral Nerve Block Catheter” (K122027) |

### Device Description:

Epimed's Spirol® Block Continuous Peripheral Nerve Block Catheter has the following characteristics:

- · 19 Ga. & 20 Ga., 14" to 24" in length.
- · Offered in open and closed end distal tip configurations.
- · Offered in styletted and non-styletted versions.
- · Internal radiopaque, echogenic coiled reinforced wire to allow visibility under fluoroscopy and/or ultrasound.
- · Catheters to be provided in sterile kit/set style configurations or as a standalone replacement catheter.

141 Sal Landrio Drive • Crossroads Business Park • Johnstown • NY • 12095 • USA 1-800-866-3342 = 1-518-725-0209 · Fax: 1-518-725-0207 · Website: www.epimedpain.com · cserve@epimedint.com

{1}------------------------------------------------

Image /page/1/Picture/0 description: The image shows the logo for "Epimed", with the tagline "Designed by Experts for Experts" underneath. The logo features a stylized letter "A" to the left of the word "Epimed". The text and logo are in black against a white background.

### Statement of Intended Use:

The catheter is designed to deliver anesthesia to manage perioperative pain and/or alleviate postoperative analgesia.

### Statement of Indications For Use:

The Spirol® Block Continuous Peripheral Nerve Block Catheter permits placement of catheters next to nerve plexuses for continuous nerve block anesthesia or analgesia techniques including upper extremity, lower extremity, abdominal and paravertebral locations for periods not exceeding 72 hours.

#### Technological Characteristics and Substantial Equivalence:

Epimed's Spirol Block Continuous Peripheral Nerve Block Catheter has identical Intended Use and Indications For Use as that of the Predicate Device #2 (K122027). The catheter itself is identical in design, manufacture and material composition to Predicate Device #1 (K981329).

The catheter is a single-use, disposable device consisting of a polymer coated stainless steel spring. The catheter is available in various lengths, as well as open-ended or closed-ended configurations; the closed-ended models having three eyes (injection ports) at the distal end. The Spirol® Block is also available in styletted or non-styletted versions, as well as 19 Ga. or 20 Ga. models. This catheter is identical in design, manufacture, and material composition to Predicate Device #1; the only difference being an expansion to the Intended Use / Indications For Use.

The catheter functions by being inserted by a trained physician into a patient by way of an introducer needle (17 Ga. needles recommended to be used to place 19 Ga. catheters. 18 Ga. needles recommended to be used to place 20 Ga. catheters). After placement to the desired peripheral nerve group, the introducer needle is withdrawn, leaving the catheter in place. An Epimed catheter connector (K051171), which is packaged with the device, can then be connected to the catheter which then allows for a standard Luer-lock connection point for a bacterial filter and/ or extension set and/or syringe/pump. Upon successful connection to the desired accessories, anesthetic agents may be delivered continuously or by bolus injection to the intended peripheral nerve group.

As the device is simple in design, there are few scientific concepts that apply; the catheter simply provides a conduit to deliver anesthesia. The polymer coated stainless steel spring has been proven to resist kinking, collapsing and shearing, and has the ability to withstand a minimum acceptable tensile force. The materials used to construct the device have been tested for compatibility with drugs used for performing peripheral nerve blocks. The catheter injection ports have been designed to remain patent and deliver injectants at a flow rate sufficient for the intended use. Lastly, the catheter and the connector with which it is packaged have been tested and proven to be compatible with each other.

141 Sal Landrio Drive . Crossroads Business Park . Johnstown . NY . 12095 . USA 1-800-866-3342 • 1-518-725-0209 • Fax: 1-518-725-0207 • Website: www.epimedpain.com • cserve@epimedint.com

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for "Epimed", with the tagline "Designed by Experts for Experts" underneath. The logo features a stylized letter "E" with a triangle shape attached to the left side. The word "Epimed" is written in bold, sans-serif font. The tagline is written in a smaller, italicized font.

There are no technological differences among the subject and predicate devices as the subject device, as well as both predicates, are:

- Single-use, disposable devices consisting of a polymer coated stainless . steel spring.
- Available in various lengths, as well as open-ended or closed-ended . configurations; the closed-ended models having three eyes (injection ports) at the distal end.
- Available in styletted or non-styletted versions. .
- Available in 19 Ga. or 20 Ga. models. .

Each catheter functions by being inserted by a trained physician into a patient by way of an introducer needle. After placement to the desired location, the introducer needle is withdrawn, leaving the catheter in place. A catheter connector can then be connected to the catheter which then allows for a standard Luer-lock connection point for a bacterial filter and/ or extension set and/or syringe/pump. Upon successful connection to the desired accessories, anesthetic agents may be delivered continuously or by bolus injection to the intended peripheral nerve group.

As the technologic characteristics across all of the referenced devices are identical, there is no effect on substantial equivalence.

#### Nonclinical Testing:

The results of the performance testing performed, i.e. dimensional, substance compatibility, kink testing, stiffness, tensile strength, connector attachment, flow test, resistance to leakage during aspiration or vacuum, resistance to leakage under pressure, corrosion resistance and skive testing, demonstrate that the Spirol® Block Continuous Peripheral Nerve Block Catheter performs comparably to, and is substantially equivalent to Predicate Device #1 (K981329) and Predicate Device #2 (K122027).

Pre-Clinical Design Validation studies have been performed on the Spirol® Block Continuous Peripheral Nerve Block Catheter. Based on the evaluation results, the Spirol® Block has been proven to conform to physician's needs, is suitable for its intended use, meeting the requirements of the Design Inputs.

In accordance with the applicable sections of ISO 10993, the relevant patient contacting components have been shown to meet the necessary biocompatibility requirements. The biocompatibility of the materials used to manufacture the Spirol® Block have been proven substantially equivalent through laboratory testing performed and documented in the Spirol® Catheter Biocompatibility Assessment. The biocompatibility testing which has been performed includes the following:

- Cytotoxicity (per ISO 10993-5) .
- . Sensitization (per ISO 10993-10)
- Irritation or Intracutaneous Reactivity (per ISO 10993-10) .
- Acute Systemic Toxicity (per ISO 10993-11) catheter only .
- Sub-acute / Sub-chronic Toxicity (per ISO 10993-11) catheter only .
- . Genotoxicity (per ISO 10993-3) catheter only
- Implantation (per ISO 10993-6) catheter only .

141 Sal Landrio Drive . Crossroads Business Park . Johnstown . NY . 12095 . USA 1-800-866-3342 • 1-518-725-0209 • Fax: 1-518-725-0207 • Website: www.epimedpain.com • cserve@epimedint.com

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows the logo for "Epimed", with the tagline "Designed by Experts for Experts" underneath. The logo is in bold, black font and has a horizontal line on either side. The "E" in Epimed is stylized with a triangle shape on the left side.

Lastly, in accordance with ISO 10993-18 Biological Evaluation of Medical Devices - Part 18: Chemical Characterization of Materials) Annex C (Principles for Judging Toxicological Equivalency) part c) The materials comprising the Spirol® Block have already been established in a more invasive exposure (Epidural applications) than this less invasive proposed application (Peripheral applications).

#### Conclusions:

The results of bench and laboratory testing demonstrate that Epimed's Spirol® Block Continuous Peripheral Nerve Block Catheter is substantially equivalent to the cited predicate devices.

Pestur ferin

Preston H. Frasier Manager - QA/RA Epimed International, Inc. prestonf@epimedint.com

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes representing the department's mission. The eagle is encircled by the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement.

#### DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring MD 20993-0002

May 28, 2014

Epimed International, Inc. Preston Frasier Manager - QA/RA 141 Sal Landrio Dr. Crossroads Business Park Johnstown, NY 12095

Re: K133316

Trade/Device Name: Spirol Block Continuous Peripheral Nerve Block Catheter Regulation Number: 21 CFR 868.5120 Regulation Name: Anesthesia Conduction Catheter Regulatory Class: Class II Product Code: BSO Dated: April 21, 2014 Received: April 28, 2014

Dear Mr. Frasier:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{5}------------------------------------------------

Page 2 - Mr. Frasier

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safetw/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

Sincerely yours,

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Tejashri Purohit-Sheth, M.D.

Tejashri Purohit-Sheth, M.D.
Clinical Deputy Director
ADAGRID/ODE/CDRII FOR

Erin I. Keith, M.S. Acting Director Division of Anesthesiology, General Hospital, Respiratory. Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{6}------------------------------------------------

### Indications for Use

510(k) Number (if known) K133316

#### Device Name

The Spirol® Block Continuous Peripheral Nerve Block Catheter

#### Indications for Use (Describe)

The Spirol® Block Continuous Peripheral Nerve Block Catheter permits placement of catheters next to nerve plexuses for coninuous nerve block anesthesia techniques including upper extremity, lower extremity, abdominal and paravertebral locations for periods not exceeding 72 hours.

Type of Use (Select one or both, as applicable)

> Prescription Use (Part 21 CFR 801 Subpart D)

] Over-The-Counter Use (21 CFR 801 Subpart C)

## PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON A SEPARATE PAGE IF NEEDED.

FOR FDA USE ONLY الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع المو . " Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)

Image /page/6/Picture/12 description: The image shows the text 'Todd D. Courtney-S' on the first line and '2014.05.28 12:45:48 -04'00' on the second line. The text appears to be a timestamp or a record of some event. The font is simple and clear, making the text easily readable. The overall impression is that this is a digital record or a label.

Form Approved: OMB No. 0910-0120 Expiration Date: December 31, 2013 See PRA Statement on last page.

{7}------------------------------------------------

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW."

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration . Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

---

**Source:** [https://fda.innolitics.com/device/K133316](https://fda.innolitics.com/device/K133316)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
