K132923 · Angelus Industria DE Productos Odontologicos SA · KLE · Jan 3, 2014 · Dental
Device Facts
Record ID
K132923
Device Name
FUSION SINGLE LINK
Applicant
Angelus Industria DE Productos Odontologicos SA
Product Code
KLE · Dental
Decision Date
Jan 3, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3200
Device Class
Class 2
Indications for Use
Bonding all classes of direct composite restorations as well as for indirect procedures involving metal, porcelain, or composite crowns, inlays or onlays. The Angelus products multi-purpose systems also bond amalgam and self-cure composite can be used to bond orthodontic brackets to enamel.
Device Story
Fusion Single Link is a one-bottle dental adhesive system; functions as both primer and adhesive. Used by dental professionals in clinical settings for restorative procedures. System applied to tooth structure; polymerizes upon exposure to visible light from dental curing light. Facilitates bonding of direct composite restorations, indirect restorations (metal, porcelain, composite), amalgam, and orthodontic brackets. Benefits patient by providing adhesive interface for dental repairs and restorations.
Clinical Evidence
Bench testing only. Performance evaluated per ISO/TS 11405:2003 (testing of adhesion to tooth structure). Metrics included bond strength (tensile/shear), marginal gap measurement, and microleakage. Results confirmed average strength and resistance are substantially equivalent to the predicate device.
Technological Characteristics
Light-cured resin adhesive system. Supplied as unit dose or vial. Functions as primer and adhesive. Polymerizes via visible light curing. Complies with ISO/TS 11405:2003 for bond strength testing.
Indications for Use
Indicated for bonding direct composite restorations, indirect procedures (metal, porcelain, or composite crowns, inlays, onlays), amalgam, self-cure composite, and orthodontic brackets to enamel.
Regulatory Classification
Identification
A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted on the interior of a prepared cavity of a tooth to improve retention of a restoration, such as a filling.
{1}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for Angelus. The logo consists of a black circle with a white triangle inside, followed by the word "angelus" in black lowercase letters. Below the word "angelus" is some smaller text that is difficult to read.
CONFIDENTIAL
# SECTION 6
510(k) Summary
Proprietary Name K Number Date Prepared
Fusion Single Link K132923 December 3, 2013
Submitter
Angelus Industria de Productos Odontologicos Waldir Landgraf, 101 Londrina, Brazil 86031-3200
Telephone: +55 43 2101 3200
Official Contact
Tara Conrad TechLink International Consulting 18851 NE 29th Avenue Suite 720 Aventura, FL 33180 TEL- (305) 377-0077
Common Name: Trade Name: Classification: Product Code: Classification Panel: Requlation Numbers: Substantial Equivalence:
Resin Tooth Bonding Agent Fusion Single Link Class II KLE Dental 21 CFR 872.3200 K962785 3M Dent System (Single Bond) by 3M Company
#### Description of Proposed Device
The Fusion Single Link by Angelus is a versatile system for dental bonding. It is a onebottle adhesive system, indicated for restorations, adhesive cementation of indirect restorations (cast metal, porcelain and composite resin veneers) and intraradicular posts (cast metal and prefabricated in metal or fiber). It can also be used for the bonding of orthodontic brackets, and for the repair of porcelain restorations.
#### Indications for Use
Bonding all classes of direct composite restorations as well as for indirect procedures involving metal, porcelain, or composite crowns, inlays or onlays. The Angelus products multi-purpose systems also bond amalgam and self-cure composite can be used to bond orthodontic brackets to enamel.
{2}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the logo for Angelus. The logo consists of a circular icon with a stylized "A" inside, followed by the word "angelus" in a bold, sans-serif font. Below the word "angelus" are smaller words that are difficult to read.
# Device Comparison Table
| | Subject Device | Predicate Device |
|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| | Fusion Single Link by Angelus | K962785 3M Dent System (Single<br>Bond) by 3M Company |
| Indications for use | Bonding all classes of direct<br>composite restorations as well as<br>for indirect procedures involving<br>metal, porcelain, or composite<br>enamel. | Bonding all classes of direct<br>composite restorations as well as<br>for Indirect procedures involving<br>metal, porcelain, or composite<br>crowns, inlays or onlays. The 3m<br>Dent System also bonds<br>amalgam and self-cure composite<br>can be used to bond orthodontic<br>brackets to enamel and root<br>desensitization |
| Delivery System | Unit Dose, Vial | Unit Dose, Vial |
| Material | Light Cure | Light Cure |
| Product Type | Adhesive | Adhesive |
| Film thickness | Enamel adhesive layer (µm):<br>8.2(2.40) | Enamel adhesive layer (µm):<br>6.40(2.80) |
| | Dentin adhesive layer (µm):<br>8.4(2.6) | Dentin adhesive layer (µm):<br>4.22(1.25) |
| Application time | Total time 60 second<br>Light cure time 12 seconds | Total time 57 second<br>Light cure time 10 seconds |
| Bond to Dentin | 37 MPa | 45 MPa |
## Substantial Equivalence
The predicate and subject devices are substantially equivalent because they are both adhesive systems. They have the same intended use and similar materials. They both utilize materials that will polymerize upon exposure to visible light from a dental curing light. The systems act as both a primer and an adhesive.
### Biocompatibility
Single Link has the same composition and applications as its predicate. This product is for permanent contact with tissue, bone and dentin.
### Performance Data
Based on performance data according the ISO/TS 11405: 2003, it was found that the average strength and average resistance of the two devices are substantially equivalent.
ISO/TS 11405: 2003- Dental materials -- testing of adhesion to tooth structure
ISO 11405:2003 gives guidance on substrate selection, storage and handling as well as essential characteristics of different test methods for quality testing of the adhesive bond between restorative dental materials and tooth structure, i.e. enamel and dentine. It specifies two bond strength measurements tests (tensile and shear), a test for measurement of marginal gaps around fillings and a microleakage test, as well as giving recommendations on clinical usage tests for such materials. It also presents
{3}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the logo for Angelus Computer Technologies. The logo consists of a black circle with a white triangle inside, followed by the word "angelus" in a lowercase, sans-serif font. Below the word "angelus" are the words "computer and technologies" in a smaller, sans-serif font.
some specific test methods for bond strength measurements.
## Conclusion
Based on chemical composition, testing, and indications for use, Angelus has concluded that he subject and predicate devices are substantially equivalent that the subject device does not raise any safety or effectiveness concerns. Therefore the devices have been found to be substantially equivalent.
{4}------------------------------------------------
#### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized representation of an eagle or bird-like figure with three curved lines forming its body and wings.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
## January 3, 2014
TechLink International Consulting Ms. Tara Conrad Regulatory Affairs Manager 18851 NE 29TH Avenue Suite 720 Aventura, FL 33180
Re: K132923
Trade/Device Name: Fusion Single Link Regulation Number: 21 CFR 872.3200 Regulation Name: Resin Tooth Bonding Agent Regulatory Class: II Product Code: KLE Dated: October 9, 2013 Received: October 10, 2013
Dear Ms. Conrad:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
#### Page 2 - Ms. Conrad
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours.
Mary-S. Runner -S
Erin I. Keith. M.S. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
# Indications for Use Statement
Device Name: Fusion Single Link
510(k) Number: K132923
Indications for Use:
Bonding all classes of direct composite restorations as well as for indirect procedures involving metal, porcelain, or composite crowns, inlays or onlays. The Angelus products multi-purpose systems also bond amalgam and self-cure composite can be used to bond orthodontic brackets to enamel.
Prescription Use X (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use _ (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEED
Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1
> - Mary S. Runner -5 2014.01.03 12:36:50 -05:00
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.