K130991 · Sagemax Bioceramics, Inc. · EIH · Feb 10, 2014 · Dental
Device Facts
Record ID
K130991
Device Name
NEXXZR(TM)T AND NEXXZR(TM)S
Applicant
Sagemax Bioceramics, Inc.
Product Code
EIH · Dental
Decision Date
Feb 10, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.6660
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
NexxZr™ are intended for the fabrication and preparation of copings and full anatomical/full contour crowns, bridges, inlays, and onlays for anterior and posterior segment restorations.
Device Story
NexxZr™ T and NexxZr™ S are pre-sintered discs composed of yttria-stabilized zirconium dioxide ceramic. Used by dental laboratories or similar establishments under physician/dentist order; processed via computer-aided manufacturing (CAD/CAM) systems to fabricate dental prostheses (crowns, bridges, inlays, onlays). Dentist prepares natural tooth surface; restoration is cemented using standard dental adhesives. Material is radioopaque for visualization. Serves as alternative to gold, amalgam, or porcelain materials. Benefits include biocompatibility, high strength, and ability to withstand load/stress in long-term implantable applications.
Clinical Evidence
Bench testing only. Physical characteristics (flexural strength, solubility) measured and compared to predicate. Material tested according to ISO 6872:2008 Type II/Class 6 standards.
Technological Characteristics
Isostatically pressed, partially sintered, yttria-stabilized zirconia powder. Radioopaque. Tested to ISO 6872:2008 Type II/Class 6. Form factor: pre-sintered discs for CAD/CAM processing.
Indications for Use
Indicated for patients requiring dental restorations including copings, full anatomical/full contour crowns, bridges, inlays, and onlays for anterior and posterior segments.
Regulatory Classification
Identification
Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.
{1}------------------------------------------------
## SECTION 4: 510(k) SUMMARY
- Submitter Information: SAGEMAX BIOCERMAICS, INC., 34210 9th Avenue I. South, Suite 118, Federal Way, WA 98003 USA Contact Person: Katie J. Kosty -Phone: 877-386-0389, Fax: 888-856-2615
Date Prepared: November 26, 2013
- Classification: Porcelain powder for clinical use, EIH, Class II, described in CFR II. 872.6660.
- Common/Usual Name: Dental restorative material, porcelain powder/blocks III.
- Proprietary Names: NexxZr™ S and NexxZr"™ T (formerly Sagemax Z-Blank™) IV.
- Establishment Registration Number: 3007518500 V.
- Indications for Use: NexxZr™ are intended for the fabrication and preparation of VI. copings and full anatomical/full contour crowns, bridges, inlays, and onlays for anterior and posterior segment restorations.
- Device Description: Sagemax NexxZr™ T and NexxZr™ S are zirconium dioxide-VII. yttrium oxide ceramic material - pressed into pre-sintered discs intended for further processing using computer aided manufacturing by a dental laboratory or other similar establishment, under the order of a physician/dentist. The dentist prepares the surface(s) of the natural teeth, then cements (lutes) the restoration in place with standard dental adhesives materials. Sagemax NexxZr™ prostheses are alternatives to gold, amalgam, ceramic, porcelain, or composite filling materials, more closely resembling gold inlays or porcelain inlays, onlays or veneers. The material is radioopaque, for ready visualization.
NexxZr™ products are a modification of the previous version, Sagemax Z-Blank™
- Substantial Equivalence: Sagemax NexxZx™ materials are substantially equivalent VIII. to our current, legally marketed device, K062695, Sagemax Z-Blanks; they are intended for the same purpose, namely to fabricate crowns (temporary or permanent) that are fully anatomical and contoured mimicking natural teeth. Yttrium-stabilized zirconia has been studied extensively for use in medical applications. The material is inert (biocompatible) and ideal for long-term implantable devices that resist failure under extreme load and stress. There are numerous dental devices that have been cleared by the Agency that apply the same fundamental scientific technology with regard to design and process. These devices have shown to be substantially equivalent in safety and/or effectiveness to the predicate device. Therefore, NexxZr™ S and NexxZr™ T are substantially equivalent to the following predicate device:
K062695 - Sagemax Bioceramics - Sagemax Z-Blank
{2}------------------------------------------------
#### Description of Safety and Substantial Equivalence:
#### Technological Characteristics
NexxZr" is an oxide-based ceramic composed of isostatically pressed, partially sintered, yttria-stabilized zirconia powder. NexxZr 10 is tested according to ISO 6872: 2008 Type II/Class 6 to ensure intended strength. This material is similar to dental alloys containing gold. Predicate devices have been used extensively and were found to be safe for dental use. The devise has the same technological characteristics and composition as the predicate device Sagemax Z-blank™.
#### Non-Clinical Performance Data
Measurements of the physical characteristics showed that the material has the same mechanical (flexural strength) and chemical stability (solubility) as our predicate device.
#### Conclusion as to Substantial Equivalence
The physio-chemical properties of the raw material used in Sagemax devices, in addition to its technological characteristics are the same as in our previously cleared predicate device. The substantial equivalence of the intended use has also been proven by material testing (flexural strength - ISO 6872: 2008) and clinical performance.
The devices are meant to be used in the same manner as current, legally marked devices. They are intended to be used in conjunction with CAD/CAM systems that meet the requirements under the recently issued FDA Class II Special Controls Guidance for Optical Impression Systems.
{3}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo features a stylized eagle with three swooping lines representing the agency's mission. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
February 10, 2014
Sagemax Bioceramics, Inc. Ms. Kathryn J. Kosty Vice President 34210 9th Avenue South, Suite 118 Federal Way, WA 98003
Re: K130991
Trade/Device Name: NexxZr® T and NexxZr® S Regulation Number: 21 CFR 872.6660 Regulation Name: Porcelain Powder for Clinical Use Regulatory Class: II Product Code: EIH Dated: December 2, 2013 Received: December 5, 2013
Dear Ms. Kosty:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2 - Ms. Kosty
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.goy/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Image /page/3/Figure/6 description: The image shows the name "Kwame Oduimer -S" in a stylized font. The name is written in black ink on a white background. The letters are bold and have a slightly distressed appearance. The letters "Oduimer" are stylized with geometric shapes.
for
Erin I. Keith, M.S. Acting Division Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
### Indications for Use
510{k) Number (if known) K130991
Device Name NexxZx S and NexxZr T
Indications for Use (Describe)
Indications for Use (2837109)
NexxZr T and NexxZr S are intended for the fabrication and preparation of copings and full anatomical/full contour crowns, bridges, inlays, and onlays for anterior and posterior segment restorations.
Type of Use {Select one or both, as applicable)
[≥] Prescription Use (Part 21 CFR 801 Subpart D)
□ Over-The-Counter Use (21 CFR 801 Subpart C)
# PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON A SEPARATE PAGE IF NEEDED.
#### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signalure)
PSC Publishing Services (101) 443-4740
Form Approved: OMB No. 0910-0120 Expiration Date: December 31, 2013 See PRA Statement on last page.
{6}------------------------------------------------
This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.