K130410 · Xianyang North West Medical Instrument (Group) Co. · EIA · Jul 26, 2013 · Dental
Device Facts
Record ID
K130410
Device Name
DENTAL UNIT WITH CHAIR
Applicant
Xianyang North West Medical Instrument (Group) Co.
Product Code
EIA · Dental
Decision Date
Jul 26, 2013
Decision
SESE
Submission Type
Special
Regulation
21 CFR 872.6640
Device Class
Class 1
Indications for Use
The Dental Unit with Chair is intended to supply power to and serve as a base for dental devices and accessories. It is intended for use in the dental clinic/office environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair.
Device Story
Dental unit with integrated chair; serves as base/power supply for dental accessories (handpieces, scalers, curing lights, syringes). Operated by dentists/technicians in clinical settings. Features connection box, assistant holder, foot control, telescopic tray arm, instrument tray, and operating light. Provides electrical power (110V) and pneumatic/hydraulic support (water/air pressure). Enables patient positioning via adjustable chair (backrest/headrest movement). Differences from predicate include power consumption, illumination intensity, and chair loading capacity/range. Supports clinical procedures by providing stable platform and utility connections for dental instrumentation.
Clinical Evidence
Bench testing only. Compliance verified against IEC 60601-1 (safety), IEC 60601-1-2 (EMC), ISO 7494-1/2 (dental unit requirements), ISO 6875 (dental chair), and ANSI/AAMI/ISO 17665-1 (sterilization). No clinical data presented.
Technological Characteristics
Operative dental unit; 110V/50-60Hz power. Includes connection box, assistant holder, foot control, telescopic tray arm, instrument tray, operating light. Chair loading capacity 200kg; movement range 390-740mm. Water pressure 0.2-0.4MPa; air pressure 0.6-0.8MPa. Standards: IEC 60601-1, IEC 60601-1-2, ISO 7494-1/2, ISO 6875, ANSI/AAMI/ISO 17665-1.
Indications for Use
Indicated for use in dental clinic/office environments by trained dentists, dental technicians, and assistants to provide power and a base for dental devices and accessories.
Regulatory Classification
Identification
A dental operative unit and accessories is an AC-powered device that is intended to supply power to and serve as a base for other dental devices, such as a dental handpiece, a dental operating light, an air or water syringe unit, and oral cavity evacuator, a suction operative unit, and other dental devices and accessories. The device may be attached to a dental chair.
{0}------------------------------------------------
# Exhibit #9 510(k) Summary
This 510(k) Summary of 510(k) safety and effectiveness information is being submitted in accordance with requirements of SMDA 1990 and 21 CFR 807.92.
The assigned 510(k) Number:
- Date of Submission: January 25, 2013 1.
JUL 26. 2013
- 2. Sponsor
Xianyang North West Medical Instrument (Group) Co., Ltd No.3, Biyuan Road, Xianyang, Shaanxi, 712000, China
Establishment Registration Number: 3007031016
Contact Person: Hongmei, Shangguan Position: Quality Engineer Tel: 86 29 33286870 Fax: 86 29 33212053 Email: xyshangguanhongmei@126.com
- Submission Correspondent 3. Ms. Diana Hong & Mr. Tarzan Wang Mid-Link Consulting Co., Ltd P.O. Box 237-023, Shanghai, 200237, China Tel: +86-21-22815850 Fax: 240-238-7587 Email: info@mid-link.net
- 4. Proposed Device Identification
Proposed Device Name: Dental Unit with Chair Proposed Device Model: S2310 Device Common Name: operative dental unit
Classification: I Product Code: ELA Regulation Number: 21 CFR 872.6640 Review Panel: Dental
Ed-I
{1}------------------------------------------------
Intended Use Statement:
The Dental Unit with Chair is intended to supply power to and serve as a base for dental devices and accessories. It is intended for use in the dental clinic/office environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair.
- 5. Predicate Device Identification
510(k) Number: K080438 Product Name: Dental Unit with Chair Manufacturer: North West Medical Instrument (Group) Co., Ltd
- Device Description 6.
The proposed device Dental Unit with Chair S2310 is a well equipped with two hands operation dental unit, which is intended to supply power to and serve as a base for dental devices and accessories. It is intended for use in the dental clinic/office environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair.
The proposed device is modification device to Dental Unit with Chair S2318 (K080438). It and the existed device share the same intended use, similar configuration, safety and performance.
The proposed device consists of connection box, assistant holder, foot control, telescopic tray arm, instrument tray and operating light.
#### 7. Non-Clinical Test Conclusion
Bench tests were conducted to verify that the proposed device met all design specifications as was Substantially Equivalent (SE) to the predicate device. The test results demonstrated that the proposed device complies with the following standards:
IEC 60601-1, Medical Electrical Equipment - Part 1: General Requirements for Safety, 1988; Amendment 1, 1991-11, Amendment 2, 1995.
IEC 60601-1-2: 2007, Medical Electrical Equipment -Part 1-2: General Requirements for Safety -Collateral standard: Electromagnetic Compatibility -Requirements and Tests.
ISO7494-1: 2004, Dentistry - Dental units - Part 1: General requirements and test methods.
ISO7494-2: 2003, Dentistry - Dental units - Part 2: Water and air supply.
ISO 6875: 1995, Dental patient chair.
ANSI/AAMI/ISO17665-1: 2006 Sterilization of health care products -- Moist heat -- Part 1: Requirements for the development, validation, and routine control of a sterilization process for medical devices.
After performing non-clinical performance studies, the data shows that the proposed device E9-2
{2}------------------------------------------------
Substantially Equivalent (SE) to the predicate device.
#### Substantially Equivalent Comparison and Conclusion 8.
Table III-1 Substantially Equivalent Comparison
| ITEM | Proposed Device<br>Dental Unit with Chair S2310 | Predicate Device<br>Dental Unit with Chair S2318 (K080438) | |
|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------|
| Product Code | EIA | EIA | |
| Regulation No. | 21 CFR 872.6640 | 21 CFR 872.6640 | |
| Class | I | I | |
| Intended Use | The Dental Unit with Chair is intended to<br>supply power to and serve as a base for dental<br>devices and accessories. It is intended for use<br>in the dental clinic/office environment and<br>used by trained dentists and/or dental<br>technicians and assistants. This product is<br>attached with a dental chair. | The Dental Unit with Chair is intended to<br>supply power to and serve as a base for<br>dental devices and accessories. It is intended<br>for use in the dental clinic/office<br>environment and used by trained dentists<br>and/or dental technicians and assistants. This<br>product is attached with a dental chair. | |
| Power Supply | 110V | 110V | |
| Frequency | 50/60Hz | 50/60Hz | |
| Power (with dental chair) | 400VA | 600VA | |
| Operating<br>Light | Power Supply | AC12V / 5W | AC 12V / 50W |
| | Illumination | ≤20000lx | Weak: ≤8000lx<br>Intense: ≥15000lx |
| Pressure of Water Supply | 0.2MPa-0.4MPa | 0.2MPa-0.4MPa | |
| Air Supply Pressure | 0.6MPa-0.8MPa | 0.6MPa-0.8MPa | |
| Dental<br>Chair | Loading Capacity | 200kg | 135kg |
| | Movement Range<br>(Chair) | 390mm-740mm | 410mm-750mm |
| | Movement Range<br>(Backrest) | 1°-70° | 0°-70° |
| | Movement Range<br>(Headrest) | 150mm | 150mm |
| | Accessories can be attached to<br>the device | High Speed Handpiece / Fiber Optic<br>Handpiece/ Low Speed Handpiece / Scaler /<br>Curing Light / Dental Chair /<br>Three-way-Syringe | High Speed Handpiece / Fiber Optic<br>Handpiece/ Low Speed Handpiece / Scaler /<br>Curing Light / Dental Chair /<br>Three-way-Syringe |
| | Operation Method | Control Panel / Assistant Control Panel / Foot<br>Controller | Control Panel / Assistant Control Panel /<br>Foot Controller |
Difference in Power (with dental chair), Illumination, and Dental Chair between the proposed and predicate device are discussed in the 510(k) submission documents, it is concluded that these differences will not affect the effectiveness and safety of the proposed device.
{3}------------------------------------------------
The proposed device, Dental Unit with Chair S2310, is determined to be Substantially Equivalent (SE) to the predicate device, Dental Unit with Chair (K080438), in respect of safety and effectiveness.
E9-4
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which features a staff with a serpent entwined around it. The logo is surrounded by the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement.
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G601 Silver Spring, MD 20993-0002
### July 26, 2013
Xianyang North West Medical Instrument (Group) Company, Limited C/O Ms. Diana Hong Mid-Link Consulting Company, Limited P.O. Box 237-023 Shanghai, China 200237
Re: K130410
Trade/Device Name: Dental Unit with Chair Regulation Number: 21 CFR 872.6640 Regulation Name: Dental Operative Unit and Accessories Regulatory Class: I Product Code: EIA Dated: June 25, 2013 Received: June 28, 2013
Dear Ms. Hong:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
Page 2 - Ms. Hong
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Image /page/5/Picture/8 description: The image shows the name "Mary S. Bunner -S" in a bold, sans-serif font. The letters "Mary" and "-S" are in a solid black color, while the letters "S. Bunner" appear to be filled with a pattern of smaller letters or symbols, giving them a textured look. The text is horizontally oriented and appears to be a title or heading.
Kwame Ulmer, M.S. Acting Division Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
Premarket Notification 510(k) Submission
# Section II Indications for Use
510(k) Number: K130410
Device Name: Dental Unit with Chair
Indications for Use:
The Dental Unit with Chair is intended to supply power to and serve as a base for dental devices and accessories. It is intended for use in the dental clinicoffice environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair.
OPRESCRIPTION USE (Part 21 CFR 801 Subpart D) OVER-THE-COUNTER USE (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Page I of I
Mary S. Runner -S
Susan Runnn DOS, MA 2013.07.26
10:50:57-04'00'
(Division Sign-Off)
Division of Anesthesiology, General Hospital
Infection Control, Dental Devices
**510(k) Number:** K130410
:
.
11-1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.