K123550 · United Orthopedic Corporation · LPH · May 1, 2013 · Orthopedic
Device Facts
Record ID
K123550
Device Name
UTF STEM, REDUCED
Applicant
United Orthopedic Corporation
Product Code
LPH · Orthopedic
Decision Date
May 1, 2013
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3358
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
This device is indicated for use in total hip replacement or bipolar hip replacement undergoing primary and revision surgery for the following conditions: non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusion acetabuli, and painful hip dysplasia; inflammatory degenerative joint disease such as rheumatoid arthritis; correction of functional deformity; treatment of non-union, femoral neck fracture and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques; revision procedures where other treatments or devices have failed. This device is designed for cementless use.
Device Story
Modular, wedge-shaped femoral hip stem; forged Ti-6Al-4V alloy (ASTM F136); proximal plasma-coated with CP Ti powder (ASTM F1580). Designed for cementless implantation in total or bipolar hip replacement. Modification of predicate UTF Stem (K110245) featuring reduced distal width and enlarged impact hole thread diameter for improved stem holder mechanical strength. Available in standard and high offset options; sizes #1-11. Used in conjunction with various compatible femoral heads (metal/ceramic), acetabular cup liners, and bipolar implants. Implanted by orthopedic surgeons in clinical settings to restore hip function, address degenerative disease, or treat fractures. Benefits include anatomical fit and mechanical stability.
Clinical Evidence
No clinical data. Bench testing only. Fatigue testing (stem and neck) performed per ISO 7206-4 and ISO 7206-6. Coating characterization (chemical, microstructural, mechanical) performed per FDA guidance for metallic plasma-sprayed coatings. FEM analysis used to validate mechanical strength of design modifications.
Technological Characteristics
Material: Ti-6Al-4V alloy (ASTM F136); Coating: CP Ti powder (ASTM F1580) plasma spray (500±127μm). Design: Modular, wedge-shaped, 12/14 neck taper, 130° neck angle. Cementless fixation. Sizes #1-11. Standard and high offset options.
Indications for Use
Indicated for patients undergoing primary or revision total or bipolar hip replacement for non-inflammatory degenerative joint disease (osteoarthritis, avascular necrosis, ankylosis, protrusion acetabuli, painful hip dysplasia), inflammatory degenerative joint disease (rheumatoid arthritis), functional deformity, non-union, femoral neck/trochanteric fractures, or failed prior treatments.
Regulatory Classification
Identification
A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.
{1}------------------------------------------------
510(k) Summary
# 510(k) Summary of Safety and Effectiveness
| Submitted by: | United Orthopedic Corporation | | | | | | | | | | | | | | | |
|-----------------------------|--------------------------------------------------------------|--|-------------------|-------------------|--------------|----------|-----------------------|--------------------------------------------------------------|---------------------|--------------------------------------------|--------------|----------|------------|---------------------|---------------------|---------------|
| Address: | No 57, Park Ave 2, Science Park, Hsinchu 300, Taiwan | | | | | | | | | | | | | | | |
| Phone Number: | +886-3-5773351 ext. 2212 | | | | | | | | | | | | | | | |
| Fax Number: | +886-3-5777156 | | | | | | | | | | | | | | | |
| Date of Summary: | November 15, 2012 | | | | | | | | | | | | | | | |
| Contact Person: | Fang-Yuan Ho | | | | | | | | | | | | | | | |
| | Manager, Regulatory Affairs | | Proprietary Name: | UTF Stem, reduced | Common Name: | Hip Stem | Device Classification | Hip joint metal/polymer/metal semi-constrained porous-coated | Name and Reference: | uncemented prosthesis under 21CFR 888.3358 | Device Class | Class II | Panel Code | Orthopaedics Device | Device Product Code | LPH, KWY, LZO |
| Manager, Regulatory Affairs | | | | | | | | | | | | | | | | |
| Proprietary Name: | UTF Stem, reduced | | | | | | | | | | | | | | | |
| Common Name: | Hip Stem | | | | | | | | | | | | | | | |
| Device Classification | Hip joint metal/polymer/metal semi-constrained porous-coated | | | | | | | | | | | | | | | |
| Name and Reference: | uncemented prosthesis under 21CFR 888.3358 | | | | | | | | | | | | | | | |
| Device Class | Class II | | | | | | | | | | | | | | | |
| Panel Code | Orthopaedics Device | | | | | | | | | | | | | | | |
| Device Product Code | LPH, KWY, LZO | | | | | | | | | | | | | | | |
| Predicate Device: | "UNITED" UTF Stem (K110245) | | | | | | | | | | | | | | | |
## Device Description:
This subject device is a modification and an additional size extension to the previously cleared "UNITED" UTF Stem (K110245). The materials, safety and effectiveness of this subject device are identical to "UNITED" UTF Stem (K110245). Compared with the UTF Stem (K110245), the distal width of UTF Stem-reduced is reduced to provide more selection for clinical demand, and the thread diameter of impact hole of UTF Stem-reduced is enlarged to increase the mechanical strength of stem holder which is locked with impact hole.
UOC-FDA-025
Page: Summary - 1/4
। म
{2}------------------------------------------------
As the same as UTF Stem (K110245), UTF Stem-reduced, forged from a Ti-6A1-4V alloy (ASTM F136), is a modular, wedge-shaped stem with 12/14 neck taper and 130° neck angle. The proximal part of each femoral stem is plasma coated with CP Ti powder (ASTM F1580) in thickness 500±127μm. UTF Stem-reduced is available with standard and high offset options, and each,type is available in sizes #1~11. The specifications of UTF Stem-reduced in size #1~6 and #9 are identical with UTF Stem (K110245) in size #7.5, 9, 10, 11, 12, 13, 16.5, respectively, while size #7, 8, 10 and 11 are new items which is between size # 13 and #22 in UTF Stem (K110245). These modifications will not affect its safety and effectiveness.
For total hip replacement, UTF Stem-reduced can be used in conjunction with UNITED Femoral Head (K994078, K022520, K111546 and K122504), Ceramic Femoral Head (K103497, K112463), U2 Acetabular Cup Liner (K050262), XPE Cup Liner (K111546), U2 HA/Ti Plasma Spray Cup (K050262, K12177), U2 Ti Plasma Spray Cup (K050262, K121777) and U2 Ti Porous Coated Cup (K111546). As using with U2 Acetabular Cup Liner (K050262), UTF Stem-reduced can be used with 26 mm and 28 mm metal Femoral Head (K994078, K022520, K122504) and 28 mm Ceramic Femoral Head (K103497). As using with XPE Cup Liner (K111546), UTF Stem can be used with 28 mm, 32 mm and 36 mm metal Femoral Head (K022520, K111546, K122504) and 28 i mm, 32 mm and 36 mm Ceramic Femoral Head (K103497, K112463).
For bipolar hip replacement, UTF Stem-reduced also can be used in conjunction with 26 mm, 28 mm, 32mm and 36mm metal Femoral Head (K994078, K022520, K111546, K122504), 28 mm, 32 mm and 36 mm Ceramic Femoral Head (K103497, K112463) and Bipolar implants (K101670). UNITED Femoral Head and Bipolar Cap are made of Co-Cr-Mo alloy, while Ceramic Femoral Head is manufactured from alumina. Acetabular Cup Liner and Bipolar Cap Liner are made of UHMWPE, while U2 Acetabular Cup shells are manufactured from forged Titanium alloy.
UOC-FDA-025
Page: Summary -2/4
{3}------------------------------------------------
#### Indications:
This device is indicated for use in total hip replacement or bipolar hip replacement undergoing primary and revision surgery for the following conditions: non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusion acetabuli, and painful hip dysplasia; inflammatory degenerative joint disease such as rheumatoid arthritis; correction of functional deformity; treatment of non-union, femoral neck fracture and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques; revision procedures where other treatments or devices have failed.
This device is designed for cementless use.
### Basis for Substantial Equivalence:
The subject device is a modification and an additional size extension to the previously cleared "UNITED" UTF Stem (K110245). The safety and effectiveness of the subject device are substantially equivalent to the previously cleared "UNITED" UTF Stem (K110245), except for the reduced distal profile and increased the thread diameter of the impact hole. The modifications do not change the intended use or fundamental scientific technology.
#### Non-Clinical Testing:
The stem fatigue test and neck fatigue test for worst-case in UTF stem (K110245) have been completed according to ISO 7206-4 and ISO 7206-6, respectively. No additional non-clinical testing was performed for UTF Stem-reduced because the enlarged thread diameter of impact hole and reduced distal width did not decrease the stem fatigue strength and neck fatigue strength based on the FEM analysis.
UOC-FDA-025
Page: Summary -3/4
{4}------------------------------------------------
510(k) Summary
The chemical analysis, microstructural characterization and mechanical strength of the modified coating have also evaluated. The results conform to the requirements of FDA Guidance, "Guidance for Industry on the Testing of Metallic Plasma Sprayed Coatings on Orthopedic Implants to Support Reconsideration of Postmarket Surveillance Requirements".
Based upon engineering analysis of the design modification, UTF Stem-reduced is substantially equivalent to devices currently marketed. Therefore, the device is as safe, as effective, and performs at least as safely and effectively as legally market predicates.
### Clinical Testing:
Clinical testing was not required for this submission.
Page: Summary -4/4
{5}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird symbol with three curved lines representing its wings or body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the bird symbol.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
Letter dated: May 1, 2013
United Orthopedic Corporation % Ms. Fang-Yuan Ho Regulatory Affairs, Manager No. 57, Park Ave 2, Science Park Hsinchu, Taiwan 300
Re: K123550 Trade/Device Name: UTF Stem, reduced Regulation Number: 21 CFR 888.3358 Regulation Name: Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis Regulatory Class: Class II Product Code: LPH, KWY, LZO Dated: April 3, 2013 Received: April 4, 2013
Dear Ms. Ho:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{6}------------------------------------------------
#### Page 2 - Ms. Fang-Yuan Ho
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Mark Nimelkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
# Indication for Use
510 (k) Number (if known):__K123550
Device Name: UTF Stem, reduced
Indications for Use:
This device is indicated for use in total hip replacement or bipolar hip replacement . undergoing primary and revision surgery for the following conditions: non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusion acetabuli, and painful hip dysplasia; inflammatory degenerative joint disease such as rheumatoid arthritis; correction of functional deformity; treatment of non-union, femoral neck fracture and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques; revision procedures where other treatments or devices have failed.
This device is designed for cementless use.
Prescription Use __x (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________ (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
# Elizabeth词语rank -S
Page 1 of 1
Division of Orthopedic Devices
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.