← Product Code [ION](/productcode/ION) · K120783

# ABLE-X (K120783)

_Im-Able, Ltd. · ION · Jun 20, 2012 · Physical Medicine · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K120783

## Device Facts

- **Applicant:** Im-Able, Ltd.
- **Product Code:** [ION](/productcode/ION.md)
- **Decision Date:** Jun 20, 2012
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 890.5370
- **Device Class:** Class 1
- **Review Panel:** Physical Medicine
- **Attributes:** Therapeutic

## Indications for Use

The Able-X is indicated for use by stroke patients undergoing upper limb rehabilitation to facilitate: : - Stroke rehabilitation by muscle re-education - Maintaining or increasing range of motion

## Device Story

Able-X is a virtual reality-based exercise system for stroke rehabilitation. Input consists of physical movement captured by a wireless hand-held game controller mounted on a lightweight polymer handlebar with a fixed vertical hand grip. The controller communicates via a USB receiver dongle to a user-supplied computer running therapeutic exercise games. The system displays game play in real-time on the computer screen, providing visual feedback to the patient. Used as part of a physical therapy program, the device facilitates bilateral movement exercises. Healthcare providers incorporate the system into therapy to assist patients in muscle re-education and range of motion maintenance. The device is intended for use in clinical or home settings under the guidance of a healthcare provider.

## Clinical Evidence

No clinical data provided. Substantial equivalence is based on technological characteristics and intended use comparisons to legally marketed predicate devices.

## Technological Characteristics

System consists of a lightweight polymer handlebar with a wireless game controller and a fixed vertical hand grip. Connectivity is via a USB receiver dongle to a user-supplied computer. Software is provided via CD or internet download. Operates as a virtual reality-based training system for bilateral movement exercises.

## Regulatory Identification

Nonmeasuring exercise equipment consist of devices intended for medical purposes, such as to redevelop muscles or restore motion to joints or for use as an adjunct treatment for obesity. Examples include a prone scooter board, parallel bars, a mechanical treadmill, an exercise table, and a manually propelled exercise bicycle.

## Predicate Devices

- Encore Path's BatRac (TailWind)
- Accelerated Care Plus Corporation's OmniVR Virtual Reality Rehabilitation System

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

# K120783 PAGE I OF 2

# SECTION 2.

# 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS

# 2. 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS

JUN 2 0 2012

This 510(k) summary of safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92.

#### APPLICANT

lm-Able Ltd 2nd Floor, 92 Queens Drive Lower Hutt, New Zealand http://www.im-able.com/ Tel. +64-4-909 7304 Fax. +64-4-589 9533

OFFICIAL CORRESPONDENT Sigi Caron MedTech Consultants, Inc. · 2400 Via Carrillo Palos Verdes Estates, CA 90274 sigi(@medtechconsultants.com Tel: (310) 377-3069 Fax: (310) 265-7618

· Non-powered exercise equipment

TRADE NAME

Able-X

COMMON NAME

DEVICE CLASSIFICATION

Name: Non-measuring exercise equipment Regulation No: 890,5370 Product Code: ION Class: I Panel: Physical Medicine

#### PREDICATE DEVICE

- 트 Encore Path's BatRac (TailWind) 프 Accelerated Care Plus Corporation's OmniVR Virtual Reality Rehabilitation System
#### SUBSTANTIALLY EQUIVALENT TO:

The Able-X device is substantially equivalent in intended use and technological features to Encore Path's BatRac (TailWind), a Class I exempt device under 21 CFR §890.5370, and Accelerated Care Plus (ACP) Corporation's OmniVR Virtual Reality Rehabilitation System, a Class I exempt device under 21 CFR §890.5370.

## DESCRIPTION OF THE DEVICE SUBJECT TO PREMARKET NOTIFICATION:

The Able-X is an exercise system that uses virtual reality to promote therapeutic bilateral movement exercises through use of a wireless hand held game controller and computer games. The Able-X is comprised of a lightweight polymer handlebar with a wireless game controller mounted at one end and a fixed hand vertical hand grip at the other end of the bar. The wireless

I'm Able, Ltd. Able X: Stroke Rehabilitation Aid Traditional 510(k) Page 18 of 236

{1}------------------------------------------------

#### SECTION 2. 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS

controller communicates via a USB receiver dongle to a computer installed with therapeutic exercise games. Game play of the therapeutic exercises is controlled through the game controller and displayed in real-time on the computer screen. The Able-X therapeutic exercise games are provide on a CD or can be downloaded directly through the internet. The Able-X does not include a separate console and is intended to be operated directly through a user supplied computer that meets minimum processing and operating system requirements.

## INDICATIONS FOR USE: .

The Able-X is indicated for use by stroke patients undergoing upper limb rehabilitation to facilitate:

- . Stroke rehabilitation by muscle re-education
- 트 Maintaining or increasing range of motion

# TECHNICAL CHARACTERISTICS:

The Able-X is a stroke rehabilitation system that uses a virtual reality based training system to promote therapeutic bilateral movement exercises. The Able-X is comprised of a lightweight polymer handlebar with a wireless game controller mounted at one end and a fixed hand vertical hand grip at the other end of the bar. The wireless controller communicates via a USB receiver dongle to a computer installed with therapeutic exercise games. Game play of the therapeutic exercises is controlled through the game controller and displayed in real-time on the computer screen. The Able-X is incorporated as part of a patient's overall physical therapy program by their healthcare provider.

## PERFORMANCE DATA:

Testing confirms that the Able-X can be used according to its intended use and in an equivalent manner to the predicate devices.

### BASIS FOR DETERMINATION OF SUBSTANTIAL EQUIVALENCE:

The Able-X is substantially equivalent to the listed predicate devices with respect to their indications for use (intended use) and technical characteristics. The information and data provided in this 510(k) submission identifies no new safety or effectiveness issues.

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or bird in flight, with stylized lines representing its wings and body.

# DEPARTMENT OF HEALTH & HUMAN SERVICES

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002

JUN 200 2012

Im-Able Ltd c/o Medtech Consultants, Inc Sigi Caron 2400 Via Carillo Palos Verdes Estates, California 90274

Re: K120783 Trade/Device Name: Able-X Regulation Number: 21 CFR 890.5370 Regulation Name: Nonmeasuring exercise equipment Regulatory Class: Class I Product Code: ION Dated: March 9, 2012 Received: May 10, 2012

# Dear Sigi Caron:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

# Page 2 - Sigi Caron

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHQffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours,

Mark V. Melling

Mark N. Mel Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

# SECTION 1.

## 1. INDICATIONS FOR USE STATEMENT

510(k) Number (if known): K120783

Device Name: Able-X

Indications for Use:

The Able-X is indicated for use by stroke patients undergoing upper limb rehabilitation to facilitate: :

- Stroke rehabilitation by muscle re-education
- Maintaining or increasing range of motion

Prescription Use X (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use ਮ (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

# Concurrence of CDRH, Office of Device Evaluation (ODE)

(Division Sign-Off Division of Surgical, Orthopedic, and Restorative Devices

510(k) Number K120783

Page of

I'm Able, Ltd. Able X: Stroke Rehabilitation Aid Traditional 510(k) Page 17 of 236

---

**Source:** [https://fda.innolitics.com/device/K120783](https://fda.innolitics.com/device/K120783)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
