K113463 · Suzhou KD Medical Appliance Co., Ltd. · ITI · Apr 6, 2012 · Physical Medicine
Device Facts
Record ID
K113463
Device Name
POWER WHEELCHAIR
Applicant
Suzhou KD Medical Appliance Co., Ltd.
Product Code
ITI · Physical Medicine
Decision Date
Apr 6, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3860
Device Class
Class 2
Indications for Use
The device is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.
Device Story
Motor-driven powered wheelchair for indoor/outdoor mobility; intended for disabled or elderly users limited to seated position. Components: foldable frame, armrests, seat belt, backrest, seat cushion, two rear drive wheels with hub motor/electromagnetic brake assemblies, two pivoting casters, two Li-ion batteries, off-board charger, control panel, electric motor controller. User operates via joystick; movement corresponds to joystick actuation; release triggers automatic deceleration and brake engagement. Powered by two 12V 10Ah Li-ion batteries; 20 km range. Used in various environments; operated by patient.
Clinical Evidence
Bench testing only. Compliance demonstrated with ISO 7176 series (stability, energy consumption, braking, durability, etc.), ISO 10993 (biocompatibility), IEC 60601-1-2 (EMC), IEC 61960 (batteries), and ASTM D3417.
Technological Characteristics
Powered wheelchair; Li-ion battery energy source; electromagnetic braking; joystick control interface. Materials tested per ISO 10993. Standards: ISO 7176-1:1999, ISO 7176-2:2001, ISO 7176-3:2003, ISO 7176-4:2008, ISO 7176-5:2008, ISO 7176-6:2001, ISO 7176-9:2009, ISO 7176-10:2008, ISO 7176-11:1992, ISO 7176-13:1989, ISO 7176-14:2008, ISO 7176-15:1996, ISO 7176-16:1997, ISO 7176-21:2009, ISO 10993-1:2009, ISO 10993-5:2009, ISO 10993-10:2006, ISO 14971:2007, ANSI/RESNA WC.Vol.1:2009-Sec.8, IEC 60601-1-2:2007, CISPR 11:2009, IEC 61960:2011, IEC 61000-4-2:2008, IEC 61000-4-3:2010, ASTM D3417:1999.
Indications for Use
Indicated for disabled or elderly persons limited to a seated position requiring indoor and outdoor mobility assistance.
Regulatory Classification
Identification
A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
{0}------------------------------------------------
APR - 6 2012
K113463 PAGE 1 OF 3
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
#### SUZHOU KD Medical Appliance Co. Ltd.
No. 36, GuGang Rd., ChengXiang Town, TaiCang City, JiangSu Province, China, 215400 Tel: +86-512-53110088 Fax: +86-512-53110099
## 510(k) Summary
This summary of 510(k) safety and effectiveness information is being submitted in accordance with requirements of 21 CFR Part 807.92. Date of summary was prepared: Nov. 01, 2011
#### Applicant
Name: SUZHOU KD MEDICAL APPLIANCE CO., LTD.
Address: No. 36, GuGang Rd., ChengXiang Town, TaiCang City, JiangSu Province, 215400, China
Contact person: Mrs. Cheng Rui, CEO
Phone: +86-512-53110088
Fax: +86-512-53110099
#### Device
Trade name: PL001 power wheelchair
Common name: Powered wheelchair
Classification name: Powered wheelchair
Medical specialty (Panel): Physical Medicine Device
Regulation number: 890.3860
Product Code: ITI
Classification: Class II
#### Predicate devices
Ruike 3421(K070501) / Shanghai Ruike Sports Goods CO., LTD
#### Intend use of device
The device is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.
#### Device description:
The PL001 powered wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.
It consists of two foldable armrests, a seat belt, a backrest, a seat cushion, a foldable frame, two rear drive wheels with hub motor/electromagnetic brake
{1}------------------------------------------------
## SUZHOU KD Medical Appliance Co. Ltd.
No. 36, GuGang Rd., ChengXiang Town, TaiCang City, JiangSu Province, China, 215400 Tel: +86-512-53110088 Fax: +86-512-53110099
assemblies, two pivoting casters, two Li-ion batteries, an off-board battery charger, a control panel with connect cables and a electric motor controller. The device is powered by two 12 volt, 10 Ah, Li-ion batteries with 20 km(12.5 miles) range that can be recharged by an off-board battery charger that can be plugged into an AC outlet (110-220 V, 50-60 Hz) when the device is not in use.
The patient can activate the joystick to move in the direction of the joystick is actuated. When the patient releases the joystick the device slows to stop and the brakes are automatically re-engaged.
#### Summary of non-clinical tests
The PL001 powered wheelchair complied with the requirements of ISO 7176-1:1999, ISO 7176-2:2001, ISO 7176-3:2003, ISO 7176-4:2008, ISO 7176-5:2008, ISO 7176-6:2001, ISO 7176-9:2009, ISO 7176-10:2008, ISO 7176-11:1992, ISO 7176-13:1989, ISO 7176-14:2008, ISO 7176-15:1996, ISO 7176-16:1997, ISO 7176-21:2009, ISO 10993-1:2009, ISO 10993-5:2009, ISO 10993-10:2006, ISO 14971:2007, ANSI/RESNA WC.Vol.1 :2009-Sec.8, IEC 60601-1-2:2007, CISPR 11:2009, IEC 61960:2011, IEC 61000-4-2:2008, IEC 61000-4-3:2010, and ASTM D3417:1999.
#### Statement of substantial equivalence
The PL001 powered wheelchair is substantially equivalent to the Ruike 3421(K070501). They have same intended use of a motor driven, indoor and outdoor transportation vehicle to provide mobility to a disabled or elderly person limited to a seated position.
The design and technological characteristics of this device is basically similar to the predicate device. They have self-contained batteries to provide power that can be recharged by an off-board battery charger that can be plugged into an AC outlet when the devices are not in use.
They have the same user interface, joystick, the devices are allowed to move in the direction the iovstick is actuated by the user. When the user releases the joystick the devices slow to stop and the brakes are automatically re-engaged.
Although battery type, rated power of the batteries, the rear wheel dimensions, and turning radius of the device are different from predicate
{2}------------------------------------------------
## SUZHOU KD Medical Appliance Co. Ltd. No. 36, GuGang Rd., ChengXiang Town, TaiCang City, JiangSu Province, China, 215400 Tel: +86-512-53110088 Fax: +86-512-53110099
device, but the device was tested and complied with the requirements of ISO 7176-2, ISO 7176-14 and IEC 61960, so they will not affect its safety and effectiveness. While there are minor differences between the devices including overall dimensions, load capacity, wheelchair weight, curb climbing ability etc, do not alter the intended use function and use of the device. Moreover, the non-clinical tests and the predicate comparisons demonstrate that these differences in their technological characteristics do not raise any questions as to the safety and effectiveness and, therefore the PL001 powered wheelchair is substantially equivalent to the predicate device.
#### Conclusion
In accordance with the Federal Food, Drug and Cosmetic Act, 21 CFR Part 807 and based on the information provided in this premarket notification, SUZHOU KD MEDICAL APPLIANCE CO., LTD. concludes that, PL001 powered wheelchair is substantially equivalent to predicate device as described herein.
3
{3}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the circumference. Inside the circle is a stylized image of an eagle with its wings spread, symbolizing the department's mission to protect the health of all Americans.
## Food and Drug Administration 10903 New Hampshire Avenue
Document Control Room -W066-G609 Silver Spring, MD 20993-0002
Public Health Service
Suzhou KD Medical Appliance Co., Ltd. % IRC USA Ms. Junnata Chang 16 F-2 (16A), NO. 462 SEC. 2 Chongde Road, Beitun District Taichung China (Taiwan) 406
Re: K113463 ·
Trade/Device Name: Power Wheelchair, PL001 Regulation Number: 21 CFR 890.3860 Regulation Name: Powered wheelchair Regulatory Class: Class II Product Code: ITI Dated: March 20, 2012 Received: March 26, 2012
APR - 6 2012
## Dear Ms. Chang:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to eoninered pror to tria) 2011-12-11 in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The I ou may, alerterey, mains of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it If your dovieet to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean i lease of advisou that i Dr over device complies with other requirements of the Act that I DA has made a colorizations administered by other Federal agencies. You must of any I coclar statutes and regulanents, including, but not limited to: registration and listing (21 Comply with an the Fet 5 requireman 801); medical device reporting (reporting of medical CI K r at 607), laoemig (21 CFR 803); good manufacturing practice requirements as set
{4}------------------------------------------------
## Page 2 - Ms. Junnata Chang
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Mark A. Milliken
Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Statement of Indications for Use
510(k) Number (if known): __
Device Name: Power Wheelchair, PL001
Indications for use:
The device is a motor driven. indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.
Over-The-Counter Use __X Prescription Use (Part 21 CFR 807 Subpart C) AND/OR (Part 21 CFR 801 Subpart D) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Page 1 of 1
signature
(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices
510(k) Number K113463
(Posted November 13, 2003)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.