K111338 · Avinger, Inc. · PDU · Aug 11, 2011 · Cardiovascular
Device Facts
Record ID
K111338
Device Name
WILDCAT CATHETER
Applicant
Avinger, Inc.
Product Code
PDU · Cardiovascular
Decision Date
Aug 11, 2011
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.1250
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Wildcat Catheter is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.
Device Story
Sterile, single-use, 6F-compatible, 110 cm percutaneous catheter; designed to cross chronic total occlusions (CTOs) in peripheral vasculature. Features distal tip and bilateral wedges visible under fluoroscopy; allows manual manipulation via proximal handle. Used by physicians in clinical settings to facilitate intraluminal placement of 0.035" guidewires beyond stenotic lesions. Once guidewire is positioned, enables subsequent use of atherectomy devices, PTCA catheters, or stents. Benefits patient by providing a crossing mechanism when conventional guidewires fail, facilitating further percutaneous intervention.
Clinical Evidence
CONNECT Study: multi-center, prospective, non-randomized study (n=84). Evaluated safety/effectiveness in crossing femoropopliteal CTOs (Rutherford 2-5). Primary effectiveness endpoint (successful CTO crossing and guidewire placement) achieved in 89.3% of subjects. Primary safety endpoint (composite of MAEs and angiographic complications) met; 4.8% clinically significant perforation rate, 0% MAEs.
Technological Characteristics
6F guide-compatible, 110 cm length, 0.035" guidewire compatible. Features distal tip and bilateral wedges for CTO crossing. Fluoroscopically visible components. Manual operation via proximal handle. Sterile, single-use, disposable. No software or electronic components.
Indications for Use
Indicated for patients with Peripheral Artery Disease (PAD) presenting with 99-100% stenosed femoropopliteal arteries (1-30 cm length) requiring guidewire placement beyond chronic total occlusions (CTOs). Contraindicated for use in iliac, coronary, cerebral, or carotid vasculature.
Regulatory Classification
Identification
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
Predicate Devices
Avinger Wildcat 6F Guidewire Support Catheter (K102022)
{0}------------------------------------------------
#### SECTION 5 510(k) SUMMARY (CONT.)
#### 510(k) Notification K111338
# GENERAL INFORMATION
AUG 1 1 2011
#### Applicant:
Avinger, Inc. 400 Chesapeake Drive Redwood City, CA U.S.A. Phone: 650-241-7900 Fax: 650-241-7901
#### Contact Person:
Kit Cariquitan Regulatory Consultant for Avinger, Inc. Experien Group, LLC 755 Mathilda Avenue, Suite 100 Sunnyvale, CA 94086 U.S.A. Phone: 408-400-0856 Fax: 408-400-0865
### Date Prepared: May 10, 2011
### DEVICE INFORMATION
Trade Name:
Wildcat Catheter
# Generic/Common Name:
Catheter, Percutaneous
#### Classification:
21 CFR§870.1250, Percutaneous catheter
#### Product Code:
DQY
{1}------------------------------------------------
# SECTION 5 510(k) SUMMARY (CONT.)
# PREDICATE DEVICE(S)
- Avinger Wildcat 6F Guidewire Support Catheter (K102022) .
- LuMend Frontrunner® CTO Catheter (K033535) .
- FlowCardia Crosser System (K072776) ●
### INTENDED USE
The Wildcat Catheter is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.
### PRODUCT DESCRIPTION
The Wildcat Catheter is a sterile, single-use, disposable catheter designed to cross chronic total occlusions (CTOs) and to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions in the peripheral vasculature.
The Wildcat Catheter consists of the distal tip, catheter shaft, and proximal handle that allows for manual device manipulation and a means for flushing the catheter lumen. The catheter is 6F guide compatible, 110 cm long, and intended for use with 0.035" guidewires. Two key elements of the device define the treatment modality - the distal tip and the bilateral wedges. Both elements are visible through fluoroscopy and allow for CTO crossing and facilitation of guidewire placement.
Subsequent to conventional guidewire placement, atherectomy devices, PTCA catheters, and/or stents may be used to provide therapeutic benefit.
#### SUBSTANTIAL EQUIVALENCE
The Wildcat Catheter is substantially equivalent to the Wildcat 6F Guidewire Support Catheter, the LuMend Frontrunner CTO Catheter, and the FlowCardia Crosser System. The subject device and the predicate devices are peripheral percutaneous catheters. The subject device and the Wildcat 6F Guidewire Support Catheter are identical in design, manufacturing, operation, and material composition. The proposed indications for the subject device is substantially equivalent to the indications for use for the LuMend Frontrunner® CTO Catheter and the FlowCardia Crosser System. Any differences in the technological characteristics between the devices do not raise any new issues of safectiveness. Thus, the Wildcat Catheter is substantially equivalent to the predicate devices.
#### TESTING IN SUPPORT OF SUBSTANTIAL EQUIVALENCE DETERMINATION
All necessary nonclinical and clinical testing was conducted to support a determination of substantial equivalence to the predicate devices.
{2}------------------------------------------------
# SECTION 5 510(k) SUMMARY (CONT.)
# Nonclinical Testing Summary:
The Wildcat Catheter performance characteristics were evaluated in the following in vitro and in vivo studies.
- Visual and Dimensional Verification ●
- Tensile Testing
- Torque Testing ●
- . Guidewire advancement
- Device Advancement ●
- . Tip Deflection
- Device leak testing .
- Luer Leak Testing .
- Slider Force Testing .
- Flexibility/Trackability .
- Spiral Blade Functional Testing .
- Tip Deflection Testing .
- . Coating Friction Testing
- . Biocompatibility
- In Vitro Simulated Use Testing ●
- . Device Evaluation in Porcine Model
- Packaging Testing ●
- . Shipping Testing
- Sterility Testing
- Shelf Life Testing
The collective results of the nonclinical testing demonstrate that the Wildcat Catheter meets the established specifications necessary for consistent performance for its intended use. In addition the testing demonstrates that the Wildcat Catheter does not raise new questions of safety or effectiveness when compared to the predicate devices.
# Clinical Testing Summary:
A multi-center, prospective, non-randomized study (CONNECT Study) was conducted to evaluate the safety and effectiveness of the Wildcat Catheter used to cross chronic total occlusions in the superficial femoral and popliteal arteries. Subjects were followed through 30days post procedure.
The Wildcat Catheter was used in 84 subjects enrolled in the study from 15 sites in the United States. The patient population consisted of those presenting with Peripheral Artery Disease who met all eligibility criteria, including documented Rutherford Classification ranging from 2-5 and angiographic evidence of 99-100% stenosed femoropopliteal arteries that were ≥ 1 cm and ≤ 30 cm in length. Primary safety and effectiveness endpoints were based on independent angiographic reviewers.
The primary safety endpoint was a composite endpoint identified by both site reported safety data (MAEs) and angiographic data (clinically significant perforations, embolizations and Grade C or greater dissections) assessed by independent angiographic reviewers. Four (4) clinically significant perforations (4.8%) occurred at the time of the procedure identified by the independent angiographic reviewers. No further sequelae were reported by any of the subjects prior to discharge. There were no occurrences of MAEs (0.0%) or unanticipated adverse events. The primary safety endpoint was met.
Confidential
{3}------------------------------------------------
### SECTION 5 510(k) Summary (Cont.)
The primary effectiveness endpoint, defined as successful CTO crossing by the Wildcat Catheter and subsequent guidewire positioning through the distal true lumen (confirmed by angiography), was achieved in 89.3% of subjects. The primary effectiveness endpoint was met.
In conclusion, the results of the CONNECT Study demonstrate that the Wildcat Catheter was able to successfully facilitate crossing of chronic total occlusions (CTOs) in the majority of cases where a conventional guidewire was unsuccessful.
#### CONCLUSION
Based on the nonclinical and clinical testing, it may be concluded that the Wildcat Catheter satisfies safety and performance requirements when used in accordance with the Instructions for Use for the indicated patient population and does not raise any issues of safety and effectiveness. The Wildcat Catheter is substantially equivalent to the predicate devices.
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three curved lines representing its wings. The eagle is positioned to the right of a circular text that reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA". The logo is black and white.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
Avinger, Inc. Mr. Ziad Rouag Vice President of Clinical, Regulatory & Quality Affairs 400 Chesapeake Drive Redwood City, CA 94063
SEP 1 8 2013
Re: K111338 Trade/Device Name: Wildcat Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: PDU Dated: July 29, 2011
Received: August 1, 2011
Dear Mr. Rouag:
This letter corrects our substantially equivalent letter of August 11, 2011.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21
{5}------------------------------------------------
Page 2 - Mr. Ziad Rouag
CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers. International and Consumer Assistance at its tollfree number (800) 638 2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Z.M.Z.
Aram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
# SECTION 4 INDICATIONS FOR USE STATEMENT
510(k) Number (if known): K111338
Device Name: Wildcat Catheter
### Indications For Use:
The Wildcat Catheter is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.
Prescription Use _ X (21 CFR Part 801 Subpart D) And/Or
Over the Counter Use (21 CFR Part 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE; CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off)
Division of Cardiovascular Devices
510(k) Number
CONFIDENTIAL
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.