K111216 · Biomet 3i, Inc. · DZE · Nov 18, 2011 · Dental
Device Facts
Record ID
K111216
Device Name
OSSEOTITE 2 DENTAL IMPLANTS
Applicant
Biomet 3i, Inc.
Product Code
DZE · Dental
Decision Date
Nov 18, 2011
Decision
SESE
Submission Type
Special
Regulation
21 CFR 872.3640
Device Class
Class 2
Attributes
Therapeutic, Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K111216 · Nov 18, 2011
OSSEOTITE 2 DENTAL IMPLANTS
Biomet 3i, Inc.
Clinical placement experience data; Insertion torque force records; Implant failure records
The sponsor provided retrospective clinical reports summarizing insertion torque forces and implant success/failure rates from clinical practice to support the safety and performance of the OSSEOTITE® 2 Dental Implants.
Insertion torque; Implant failure; Clinical experience; Retrospective data
Clinical Evidence
Study Design
Population
Comparator
Key Endpoints
Insertional Torque Force, Osseotite 2 Placement Data, Pressure Necrosis; Retrospective analysis of clinical placement data; Follow-up/Duration: Defined follow-up time point post loading; Study Period: Report dated September 21st, 2011
BIOMET 3i Dental Implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth utilizing delayed or immediate loading, or with a terminal or intermediary abutment for fixed or removable bridgework, and to retain overdentures. OSSEOTITE® 2 Dental Implants are intended for immediate function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function.
Device Story
OSSEOTITE® 2 Dental Implants are root-form endosseous implants made of commercially pure titanium with a dual acid-etched surface. Designed for surgical placement in the jaw by dental professionals to support prosthetic restorations; implants feature a straight-wall design with an external hex connection for abutment mating. The device is provided sterile with size-appropriate cover screws. During clinical use, the implant is surgically placed into the jawbone; primary stability is required for immediate function applications. The device serves as an anchor for single or multiple tooth restorations, fixed or removable bridgework, or overdentures, restoring chewing function for the patient. The primary modification from predicate devices is the transition from an internal to an external hex connection.
Clinical Evidence
Two clinical reports provided: 'Insertional Torque Force, Osseotite 2 Placement Data, Pressure Necrosis' and 'BIOMET 3i Insertion Torque Report'. These reports summarize clinical project data regarding insertion torque forces, implant success rates at follow-up, and failure analysis. Bench testing was also conducted per ISO 14801:2007 (dynamic fatigue testing) on worst-case scenarios, including 30° pre-angled abutments, meeting all acceptance criteria.
Technological Characteristics
Material: Commercially Pure Titanium. Design: Straight-walled root-form endosseous implant with external hex connection. Surface: Proprietary OSSEOTITE dual acid-etched. Features: Self-tapping cutting flutes with apical taper; anodized seating surface; color-coded labeling. Sterilization: Gamma irradiation. Shelf life: 5 years. Mechanical testing: ISO 14801:2007.
Indications for Use
Indicated for patients requiring dental implants in the upper or lower jaw for prosthetic attachment in single tooth restorations, partially or fully edentulous spans, or to retain overdentures. Suitable for delayed or immediate loading. No specific contraindications listed.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
*Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
{0}------------------------------------------------
K111216
NOV 1 8 2011
### 510(k) Summary
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR § 807.93
| Submitter: | BIOMET 3i<br>4555 Riverside Drive<br>Palm Beach Gardens, FL 33410 |
|--------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Establishment Reg. Number: | 1038806 |
| Contact: | Martha I Garay<br>Senior Regulatory Affairs Specialist<br>BIOMET 3i<br>4555 Riverside Drive<br>Palm Beach Gardens, FL 33410<br>Tel. 561-776-6923<br>Fax. 561-514 6316<br>Email martha.garay@BIOMET.com |
| Date Prepared: | November 18th, 2011 |
| Trade/Proprietary Name: | OSSEOTITE® 2 Dental Implants |
| Common/Usual Name: | Root-Form Endosseous Dental Implant |
| Classification Name/ FDA Reviewing Branch: | Endosseous Dental Implant / Dental Panel |
| Device Classification/Code: | Class II - 21 CFR §872.3640 / DZE |
| Predicate Device Manufacturer: | K100724 - OSSEOTITE II MODEL XIFOSSXXX / BIOMET 3i<br>K063286 – OSSEOTITE Dental Implants / BIOMET 3i |
| Purpose of the SPECIAL 510(k) notice: | The reason for this Special 510k submission is to request clearance for<br>modification to a device that has been cleared under the 510(k) process<br>referred to herein as OSSEOTITE® 2 Dental Implants. Root-Form<br>Endosseous Dental Implants are referenced under 21 CFR §872.3640<br>and are considered Class II devices. |
| Device Description: | OSSEOTITE® 2 Dental Implants are similar to predicate BIOMET 3i<br>OSSEOTITE Implants, currently being sold worldwide. OSSEOTITE<br>2® Dental Implants are provided with the proprietary OSSEOTITE dual<br>acid-etched surface which has been in commercial distribution since<br>market clearance in 1995 and are made of Commercially Pure Titanium. |
{1}------------------------------------------------
Implants have a straight wall design, with an External Hex Connection. OSSEOTITE® 2 Dental Implants are offered in diameters of 3.25, 3.75, 4.0, 5.0, and 6.0 in varying lengths from 3 mm to 15 mm. Size appropriate cover screws are provided with each implant.
BIOMET 3i Dental Implants are intended for surgical placement in the Indications for Use: upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth utilizing delayed or immediate loading, or with a terminal or intermediary abutment for fixed or removable bridgework, and to retain overdentures.
> OSSEOTITE®2 Dental Implants are intended for immediate function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function.
The predicates and OSSEOTITE® 2 Dental Implants have a number of very similar and equivalent design / technological characteristics, as follows:
| Criteria | Predicate<br>OSSEOTITE II<br>MODEL<br>XIFOSSXXX<br>(Internal Hex)<br>K100724 | Predicate<br>OSSEOTITE;<br>OSSEOTITE NT;<br>XP; TG Implant(s)<br>(External Hex)<br>K063286 | Proposed<br>OSSEOTITE® 2<br>Dental Implant(s)<br>(External Hex)<br>K111216 |
|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Implant Lengths | Ø3.25: 8.5, 10.0,<br>11.5, 13.0, 15.0,<br>18.0mm<br>Ø4.0: 8.5, 10.0,<br>11.5, 13.0, 15.0,<br>18.0, 20.0mm<br>Ø5.0: 8.5, 10.0,<br>11.5, 13.0, 15.0mm<br>Ø6.0: 8.5, 10.0,<br>11.5, 13.0, 15.0mm | Ø3.25: 7<br>(actual:6.6mm), 8.5,<br>10, 11.5, 13, 15mm<br>Ø3.75: 7<br>(actual:6.6mm),, 8.5,<br>10, 11.5, 13, 15mm<br>Ø4: 7<br>(actual:6.6mm),, 8.5,<br>10, 11.5, 13, 15mm<br>Ø5: 7<br>(actual:6.6mm),, 8.5,<br>10, 11.5, 13, 15mm<br>Ø6: 7<br>(actual:6.6mm),, 8.5,<br>10, 11.5, 13, 15mm | Ø3.25: 6.5, 8.5, 10,<br>11.5, 13, 15mm<br>Ø3.75: 6.5, 8.5, 10,<br>11.5, 13, 15mm<br>Ø4: 6.5, 8.5, 10,<br>11.5, 13, 15mm<br>Ø5: 6.5, 8.5, 10,<br>11.5, 13, 15mm<br>Ø6: 6.5, 8.5, 10,<br>11.5, 13, 15mm |
| Implant Body<br>Diameters | Ø3.25, 4.0, 5.0,<br>6.0mm | Ø3.25, 3.75, 4, 5,<br>6mm | Ø3.25, 3.75, 4, 5,<br>6mm |
| Seating Platform<br>Diameter | Ø3.25: 3.4mm<br>Ø4: 4.1mm<br>Ø5: 5.0mm<br>Ø6: 6.0mm | Ø3.25: 3.4mm<br>Ø3.75: 4.1mm<br>Ø4: 4.1mm<br>Ø5: 5.0mm<br>Ø6: 6.0mm | Ø3.25: 3.4mm<br>Ø3.75: 4.1mm<br>Ø4: 4.1mm<br>Ø5: 5.0mm<br>Ø6: 6.0mm |
| Material | Commercially Pure<br>Titanium | Commercially Pure<br>Titanium | Commercially Pure<br>Titanium |
Technological Characteristics :
{2}------------------------------------------------
## 111216
| Biocompatible | Yes | Yes | Yes |
|------------------------------------------|------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------|
| Thread Design | • 60° thread &<br>0.6mm pitch<br>(Straight-Wall)<br>• 35° thread &<br>0.8mm pitch<br>(Straight-Wall) | • 60° thread &<br>0.6mm pitch<br>(Straight-Wall)<br>• 60° thread &<br>0.9mm pitch<br>(Straight-Wall) | • 60° thread &<br>0.6mm pitch<br>(Straight-Wall)<br>• 35° thread &<br>0.8mm pitch<br>(Straight-Wall) |
| Implant Design | Straight-walled<br>implant body | Straight-walled<br>implant body | Straight-walled<br>implant body |
| Self Tapping<br>Feature | Integrated cutting<br>flutes with apical<br>taper | Integrated cutting<br>flutes with apical<br>taper | Integrated cutting<br>flutes with apical<br>taper |
| Implant Surface | Full OSSEOTITE® | Full OSSEOTITE® | Full OSSEOTITE® |
| Color-Coding | • Anodized Seating<br>Surface<br>• Color-Coded<br>Labeling | • Anodized Seating<br>Surface<br>• Color-Coded<br>Labeling | • Anodized Seating<br>Surface<br>• Color-Coded<br>Labeling |
| Packaging | Packaged in sterile<br>tray with cover<br>screw | Packaged in sterile<br>tray with cover screw | Packaged in sterile<br>tray with cover<br>screw |
| Sterilization | Sterile (Gamma<br>Irradiation) | Sterile (Gamma<br>Irradiation) | Sterile (Gamma<br>Irradiation) |
| Shelf Life | 5 Years | 5 Years | 5 Years |
| Implant<br>Placement<br>Protocol | Per BIOMET 3i<br>Surgical Catalog<br>CATSM | Per BIOMET 3i<br>Surgical Catalog<br>CATSM | Per BIOMET 3i<br>Surgical Catalog<br>CATM2 |
| Implant/Abutment<br>Mating<br>Connection | Internal Hexagon<br>Connection | External Hexagon<br>Connection | External Hexagon<br>Connection |
| Mating<br>Components | All BIOMET 3i<br>Certain®<br>Restorative<br>Components | All BIOMET 3i<br>External Hex<br>Restorative<br>Components | All BIOMET 3i<br>External Hex<br>Restorative<br>Components |
Performance Data:
Clinical Data:
BIOMET 31 has conducted Design Verification Testing according to ISO 14801:2007 "Dentistry – Dynamic Fatigue Test for Endosseous Dental Implants'' on the OSSEOTITE® 2 Dental Implants under this submission. All testing conducted met the acceptance criteria and evaluated the worst case scenario including 30° pre-angled abutments as compared to predicate BIOMET 3i designs commercially in the marketplace. Performance testing data indicates that changes to the predicate device are safe and effective for its intended use and it demonstrate to be substantially equivalent. Bench Testing conducted demonstrates that the proposed device meets the mechanical properties recommendations by FDA and ISO Standards.
Two clinical reports on OSSEOTITE® 2 Dental Implants are included with this submission:
- "Insertional Torque Force, Osseotite 2 Placement Data, ● Pressure Necrosis" dated September 21st, 2011. This report provides background information on the thread design for the OSSEOTITE® 2 Dental Implants and a summary of two clinical projects where insertion torque forces are measured. The report includes an analysis of the actual insertion torque forces
{3}------------------------------------------------
# K111216
for this implant design, the success of the implants at a defined follow-up time point post loading, and a review of the implant failures and their baseline torque values. Additionally, the subject of pressure necrosis that has been alluded with implant placement procedures associated with high insertion torque forces is discussed.
- "BIOMET 3i Insertion Torque Report", dated November 10, . 2011. This report provides an overview of the implant placement experience data for the OSSEOTITE® 2 Dental Implants, including a tabulation of individual insertion torque values and implant failures.
The following FDA Guidance Document for this type of product was Performance Standards: utilized in this submission: "Guidance for Industry and FDA Staff: -Special Controls Class II - Root Form Endosseous Dental Abutment/ Implant". Also, Testing was conducted following ISO standard 14801:2007 Dentistry -- Implants - "Dynamic fatigue test for endosseous dental implants". The test articles met all predetermined acceptance criteria.
> The OSSEOTITE® 2 Dental Implants included in this submission have the same intended use, indications for use, technological characteristics, and principles of operation as previously cleared BIOMET 3i OSSEOTITE Certain® Internal and External Connection Implants per the 510(k) numbers referenced in the Predicate Devices section above.
Refer to the following substantial equivalence data table:
| Predicate OSSEOTITE II<br>MODEL XIFOSSXXX<br>(Internal Hex)<br>K100724 | Predicate<br>OSSEOTITE; OSSEOTITE<br>NT; XP; TG Implant(s)<br>(External Hex)<br>K063286 | Proposed<br>OSSEOTITE® 2 Dental<br>Implant(s)<br>(External Hex)<br>K111216 |
|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended for surgical placement<br>in the upper or lower jaw to<br>provide a means for prosthetic<br>attachment. | Intended for surgical<br>placement in the upper or<br>lower jaw to provide a<br>means for prosthetic<br>attachment. | Intended for surgical<br>placement in the upper<br>or lower jaw to provide<br>a means for prosthetic<br>attachment. |
| Intended for single tooth<br>restorations and in partially or<br>fully edentulous spans with<br>multiple single teeth utilizing<br>delayed or immediate loading,<br>or as a terminal or intermediary<br>abutment for fixed or<br>removable bridgework, and to<br>retain overdentures. | Intended for single tooth<br>restorations and in partially<br>or fully edentulous spans<br>with multiple single teeth<br>utilizing delayed or<br>immediate loading, or as a<br>terminal or intermediary<br>abutment for fixed or<br>removable bridgework, and<br>to retain overdentures. | Intended for single<br>tooth restorations and<br>in partially or fully<br>edentulous spans with<br>multiple single teeth<br>utilizing delayed or<br>immediate loading, or<br>as a terminal or<br>intermediary abutment<br>for fixed or removable<br>bridgework, and to<br>retain overdentures. |
Substantial Equivalence:
{4}------------------------------------------------
# KIII 206
| | | | retain overdentures. |
|-----------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------|----------------------|
| Provide immediate function<br>when good primary stability is<br>achieved with appropriate<br>occlusal loading to restore<br>chewing function. | Provide immediate function<br>when good primary<br>stability is achieved with<br>appropriate occlusal<br>loading to restore chewing<br>function. | Provide immediate function<br>when good primary stability is<br>achieved with<br>appropriate occlusal<br>loading to restore<br>chewing function. | |
### Conclusion:
OSSEOTITE® 2 Dental Implants and predicate designs have the same intended use, indications for use, similar technological characteristics, and principles of operation. The major technological difference between the OSSEOTITE® 2 Dental Implants and its predicates is:
- The ONLY change is the modification of the abutment . connection from an internal feature to an external hex engagement.
The differences noted above do not present new issues of safety or effectiveness for the OSSEOTITE® 2 Dental Implants.
{5}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/5/Picture/1 description: The image shows the logo for the Department of Health and Human Services (HHS) in the USA. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the seal is a stylized symbol that resembles a human figure embracing or supporting three abstract shapes, possibly representing people or services.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 .
Ms. Martha I. Garay Senior Regulatory Affairs Specialist BIOMET 3i, Incorporated 4555 Riverside Drive Palm Beach Gardens, Florida 33410
NOV 1 8 2011
Re: K111216
Trade/Device Name: OSSEOTTE® 2 - Dental Implants Regulation Number: 21 CFR 872.3640 Regulation Name: Endosseous Dental Implant Regulatory Class: II Product Code: DZE Dated: November 10, 2011 Received: November 14, 2011
Dear Ms. Garay:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{6}------------------------------------------------
Page 2 - Ms. Garay
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820): and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours.
Ph for
Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
### Enclosure
{7}------------------------------------------------
віомет зі Special 510(k) Premarket Notification - OSSEOTITE® 2 Dental Implants
Indications for Use
510(k) Number (if known): K111216
Device Name: OSSEOTITE® 2 –Dental Implants
Indications for Use:
BIOMET 3i Dental Implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth utilizing delayed or immediate loading, or with a terminal or intermediary abutment for fixed or removable bridgework, and to retain overdentures.
OSSEOTITE® 2 Dental Implants are intended for immediate function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function.
Prescription Use
Over-The-Counter Use
(Part 21 CFR 801 Subpart D)
AND/OR
(Part 21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Image /page/7/Picture/13 description: The image shows a document with the title "Concurrence of CDRH, Office of Device Evaluation (ODE)". There is a signature above the text "(Division Sign-Off)". The document also includes the division of Anesthesiology, General Hospital, Infection Control, and Dental Devices. The 510(k) Number is K111216 and the date 4/29 is at the bottom right.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.