← Product Code [LIT](/productcode/LIT) · K103751

# MUSTANG BALLOON DILATATION CATHETERS (K103751)

_Boston Scientific · LIT · Mar 22, 2011 · Cardiovascular · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K103751

## Device Facts

- **Applicant:** Boston Scientific
- **Product Code:** [LIT](/productcode/LIT.md)
- **Decision Date:** Mar 22, 2011
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 870.1250
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular
- **Attributes:** Therapeutic

## Indications for Use

The Mustang™ Balloon Dilatation Catheter is intended for dilatation of stenosis in the peripheral vascular, for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae and post-deployed stent expansion of self-expanding and balloon expandable peripheral vascular stents.

## Device Story

Over-the-wire balloon dilatation catheter; dual lumen shaft design. One lumen for 0.035" guidewire passage; second lumen for balloon inflation/deflation. Proximal Y-connector manifold with luer lock fittings. Radiopaque marker bands under balloon for positioning; silicone coating on balloon for insertion/withdrawal. Used in clinical settings by physicians for peripheral vascular stenosis and dialysis fistula lesions. Device inflated to dilate vessels or expand stents; improves blood flow/vessel patency. Benefits patient by restoring vascular access or arterial flow.

## Clinical Evidence

Bench testing only. No clinical data. In-vitro performance testing included effective length, inflation/deflation time, tensile strength, kink resistance, crossing profile, rated burst pressure (including in-stent), fatigue, compliance, and particulate evaluation. Biocompatibility testing included cytotoxicity, sensitization, reactivity, systemic toxicity, pyrogenicity, hemolysis, complement activation, hemocompatibility, and mutagenicity.

## Technological Characteristics

Over-the-wire dual lumen catheter; 3.0-12.0 mm balloon diameters; 2-20 cm lengths. Materials include silicone-based balloon coating. Radiopaque marker bands. Sterilized via established methods. Mechanical inflation/deflation. Compatible with 0.035" guidewires.

## Regulatory Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

## Predicate Devices

- SC 35 Balloon Dilatation Catheter ([K993305](/device/K993305.md))
- Bard Dorado™ PTA Balloon Dilatation Catheter ([K072283](/device/K072283.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K10375/

# 510(k) Summary per 21 CFR §807.92

.

MAR 2 2 2011

| Submitter's Name and Address | Boston Scientific Corporation<br>One Scimed Place<br>Maple Grove, MN 55311                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               |                    |                                    |
|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------|------------------------------------|
| Contact Name and Information | Anne V. Rossi<br>Manager, Regulatory Affairs<br>Phone: 763-255-0681<br>Fax: 763-494-2222<br>e-mail: rossia@bsci.com                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |                    |                                    |
| Date Prepared                | 22 December 2010                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |                    |                                    |
| Proprietary Name             | Mustang™ Balloon Dilatation Catheter                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |                    |                                    |
| Common Name                  | PTA Balloon Dilatation Catheter                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                    |                                    |
| Product Code                 | LIT, DQY                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 |                    |                                    |
| Classification               | Class II, 21 CFR Part 870.1250                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |                    |                                    |
| Predicate Devices            | SC 35 Balloon Dilatation Catheter<br>Bard Dorado™ PTA Balloon Dilatation Catheter                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | K993305<br>K072283 | 10 April 2000<br>19 September 2007 |
| Device Description           | The Boston Scientific Mustang™ Balloon Dilatation Catheter is an over-the-wire balloon catheter with a dual lumen shaft design. One lumen is used to pass the catheter over 0.035" guidewires. The second lumen communicates with the balloon and is used to inflate and deflate the balloon during the procedure. The guidewire lumen and the balloon lumen terminate at the proximal end of the catheter in a Y-connector manifold with luer lock fittings. There are radiopaque marker bands located under the balloon to aid in positioning the system during the procedure. A silicone coating is applied to the balloon to enhance insertion and withdrawal performance.<br>The Mustang™ Balloon Dilatation Catheter will be available with balloon diameters 3.0 mm to 12.0 mm, balloon lengths 2 cm to 20 cm and with shaft lengths of 40 cm, 75 cm, and 135 cm. |                    |                                    |
| Intended Use of Device       | The Mustang™ Balloon Dilatation Catheter is intended for dilatation of stenosis in the peripheral vascular, for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae and post-deployed stent expansion of self-expanding and balloon expandable peripheral vascular stents.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |                    |                                    |
| Indications for Use          | The Mustang™ Balloon Dilatation Catheter is indicated for Percutaneous Transluminal Angioplasty (PTA) in the peripheral vasculature including iliac, femoral, popliteal, tibial, peroneal, subclavian, and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This catheter is not for use in coronary arteries.<br>The Mustang™ Balloon Dilatation Catheter is also indicated for post-dilatation of balloon expandable and self-expanding stents in the peripheral vasculature.                                                                                                                                                                                                                                                                                                                       |                    |                                    |

{1}------------------------------------------------

### Comparison of Technological Characteristics

The Mustang™ Balloon Dilatation Catheter incorporates substantially equivalent device materials and design, packaging materials and design, fundamental technology, manufacturing processes, sterilization process and intended use as those featured in the Boston Scientific predicate device, SC 35 Balloon Dilatation Catheter (K993305). Mustang™ Balloon Dilatation Catheter incorporates similar design parameters and the same intended use as the Bard Dorado™ PTA Balloon Dilatation Catheter (K072283).

| Mustang Characteristic       | Synergy                                                                                                                                                                                | Dorado  |
|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|
| Manifold                     | Same material and design with minor dimensional<br>differences but serving same function.                                                                                              | Unknown |
| Pinch-Off Tube               | Same material, component and function.                                                                                                                                                 | Unknown |
| Strain Relief                | Similar designs with same material serving same<br>function.                                                                                                                           | Unknown |
| Proximal Dual Lumen Shaft    | Same material and design serving same function.                                                                                                                                        | Unknown |
| Distal Guidewire Lumen Shaft | Same design with minor difference in material but<br>serving same function.                                                                                                            | Unknown |
| Bumper Tip                   | Difference in design. Bumper tip is used in<br>conjunction with the guidewire lumen to provide for<br>a less stiff tip.                                                                | Unknown |
| Balloon                      | Difference in balloon material and design but<br>serving same function and fundamental technology.<br>The co-extruded design allows for the device to<br>achieve high burst pressures. | Unknown |
| Balloon Bonding Method       | Difference in bonding method but serving same<br>function.                                                                                                                             | Unknown |
| Marker Bands                 | Same component serving same function.                                                                                                                                                  | Unknown |
| Coating                      | Different coating but serving same function.<br>Silicone based coatings have history of use with<br>BSC cleared PTA products.                                                          | Unknown |
| Balloon Protector            | Same material and similar design both serving<br>same function.                                                                                                                        | Unknown |
| Sterilization Method         | Same method.                                                                                                                                                                           | Unknown |
| SAL                          | Same level of assurance.                                                                                                                                                               | Unknown |
| Packaging                    | Similar design with the exception of the tray.                                                                                                                                         | Unknown |

Comparison to Predicate Devices in Materials and Manufacturing

{2}------------------------------------------------

#### Comparison of Technological Characteristics (Continued)

Comparison to Predicate Devices (Synergy and Dorado) Characteristics

| Characteristic                                 | Synergy                                                                                                                                             | Dorado                              |
|------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------|
| Nominal Balloon Diameters                      | Same range serving same function.                                                                                                                   | Same range                          |
| Balloon Lengths                                | Similar range serving same function                                                                                                                 | Same range                          |
| Rated Burst Pressure (RBP)                     | Different balloon construction. Rated<br>lower than Mustang, however, tested to<br>meet rated pressures with 95% confidence<br>on 99.9% population. | Same high pressure rated<br>balloon |
| Effective Lengths                              | Similar ranges serving same function.                                                                                                               | Same ranges                         |
| Recommended Introducer<br>Sheath Compatibility | Similar ranges and compatibilities                                                                                                                  | Same ranges and<br>compatibilities  |
| Recommended Guidewire                          | Same compatibility.                                                                                                                                 | Same compatibility                  |

#### Performance Data

Bench testing and biocompatibility testing were performed to support a determination of substantial equivalence. The results of these tests provide reasonable assurance that the proposed device has been designed and tested to assure conformance to the requirements for its intended use. No new safety or performance issues were raised during the testing.

The following biocompatibility tests were completed on the Mustang™ Balloon Dilatation Catheter:

| Cytotoxicity                    | Direct Contact Hemolysis    |
|---------------------------------|-----------------------------|
| Sensitization                   | Complement Activation       |
| Intracutaneous Reactivity       | Partial Thromboplastin Time |
| Acute Systemic Toxicity         | In Vitro Hemocompatibility  |
| Materials Mediated Pyrogenicity | Ames Mutagenicity           |
| USP Physicochemical             | Mouse Lymphoma Assays       |
| Latex                           |                             |

The following in-vitro performance tests were completed of the Mustang™ Balloon Dilatation Catheter:

| Effective Length                         | Balloon Inflation/ Deflation Time        |
|------------------------------------------|------------------------------------------|
| Shaft Outer Diameter                     | Device Tensile                           |
| Balloon Crossing Profile                 | Shaft Kink Resistance                    |
| Sheath Insertion and Withdrawal<br>Force | Balloon Rated Burst Pressure in<br>Stent |
| Balloon Rated Burst Pressure             | Torque Strength                          |
| Balloon Fatigue                          | Balloon Fatigue in Stent                 |
| Balloon Compliance & Distension          | Radiopacity                              |
| Coating Integrity                        | Particulate Evaluation                   |

{3}------------------------------------------------

Based on the indications for use, technological characteristics, and safety and Conclusion performance testing, the Mustang™ Balloon Dilatation Catheter has been shown to be appropriate for its intended use and is considered to be substantially equivalent to the Boston Scientific SC 35 Balloon Dilatation Catheter (K993305) and the Bard Dorado™ PTA Balloon Dilatation Catheter (K072283).

{4}------------------------------------------------

Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three overlapping wings, representing service to the nation. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room-WO66-G609 Silver Spring, MD 20993-0002

Boston Scientific Corporation C/O Anne V. Rossi Manager, Regulatory Affairs One Scimed Place Maple Grove, MN 55311

MAR 2 2 2011

Re: K103751

Trade/Device Name: Mustang™ Balloon Dilatation Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: LIT, DQY Dated: December 22, 2010 Received: December 23, 2010

Dear Ms. Anne Rossi:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must

{5}------------------------------------------------

Page 2 - Ms. Anne Rossi

comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.html fau the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely vours.

Dvina R. Vahner

Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{6}------------------------------------------------

## Indications for Use

510(k) Number (if known): Kじらみら

Device Name: Mustang™ Balloon Dilatation Catheter

Indications For Use:

The Mustang™ Balloon Dilatation Catheter is indicated for percutaneous transluminal angioplasty (PTA) in the peripheral vasculature including iliac, femoral, popliteal, tibial, peroneal, subclavian, and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This catheter is not for use in coronary arteries.

The Mustang™ Balloon Dilatation Catheter is also indicated for post-dilatation of balloon expandable and self-expanding stents in the peripheral vasculature.

| Prescription Use            | <div> <span style="text-decoration: overline;"></span>     ✓    </div> |
|-----------------------------|------------------------------------------------------------------------|
| (Part 21 CFR 801 Subpart D) |                                                                        |

AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

uma R. Vocher

(Division Sign-Off) (Division Sign-Oll)
Division of Cardiovascular Devices

510(k) Number_

×10375

Page 1 of 1

---

**Source:** [https://fda.innolitics.com/device/K103751](https://fda.innolitics.com/device/K103751)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
